The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Product type
Contact insert
Number of positions
6
Seal present
yes
Coding
A
Thread type
M8
Insulation characteristics
Overvoltage category
III
Contact resistance
≤ 3 mΩ
Insulation resistance
≤ 100 MΩ
Nominal voltage UN
30 V
Nominal current IN
1.5 A
Connection method
SMD reflow
Flammability rating according to UL 94
V0
Seal material
FKM
Contact material
CuZn
Contact surface material
Au
Contact carrier material
PA
Connection 1
Head design
Socket
Head cable outlet
straight
Head thread type
M8
Coding
A
Ambient conditions
Degree of protection (when plugged in)
IP67 (correctly plugged in and locked)
Degree of protection (not plugged in)
IP65 (not plugged in, by means of additional O-ring seal with device)
Ambient temperature (operation) (male connector/female connector)