Mode 3 controller for charging electric vehicles in accordance with IEC 61851-1 for charging case B and C with integrated DC residual current monitoring and Ethernet communication interface.
EV-CC-AC1-M3-RCM-ETH-XP
-
AC charging controller
1139449
AC charging controller in accordance with IEC 61851-1, client or standalone, OCPP 1.6J via Ethernet, Modbus/TCP via Ethernet, connection of RFID reader and energy meter via RS-485, DC residual current monitoring, connector release in the event of power failure
Free download available.
Downloads
Product details
Product type | AC charging controller |
Product family | CHARX control advanced plus |
Application | AC charging controller for private and commercial applications (EU/CN) |
Operating mode | Stand-Alone |
Client | |
Server | |
Charging mode | Mode 3, Case B + C |
Insulation characteristics | |
Overvoltage category | II |
Charging controllers | |
Number of charging points | 1 |
Type of charging current | AC |
Current consumption | < 3 W (No-load) |
Power consumption | < 10 W |
Locking release in the event of mains failure | Integrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet |
Measuring current transducer | |
Connection method | Connector |
Diameter of measuring coil | 15 mm |
Measuring range: Residual current | |
Rated frequency fn | ≤ 2000 Hz |
Nominal differential current | ± 300 mA |
Residual current IΔn | 30 mA (AC) |
6 mA (DC) | |
Rated current In | 32 A (Three-phase, 4x6 mm²) |
48 A (Single-phase) | |
Tripping time for IΔn | < 180 ms |
Response time for 2 x IΔn | < 70 ms |
Tripping time for 5xIΔn | < 20 ms |
Supply | |
Supply voltage | 230 V |
Supply voltage range | 100 V AC ... 240 V AC (nominal voltage range) |
Nominal power consumption | < 3 W (No-load) |
Power consumption | < 10 W (maximum) |
Frequency range | 50 Hz ... 60 Hz |
Digital | |
Number of digital inputs | 5 |
Description of the input | Digital input |
Nominal current IN | ≤ 4 mA |
Nominal input voltage UN | 12 V |
Input voltage range | 0 V ... 3 V (Off) |
Input voltage range U2 | 9 V ... 15 V (On) |
Digital | |
Output name | 4 digital outputs |
Connection technology | Screw connection |
Maximum output voltage | 30 V |
Maximum output current | 0.2 A (Total current for all outputs; internally supplied) |
Maximum output current per channel | 0.6 A (Per output; externally supplied) |
Switching | |
Output name | Relay output C1.2 |
Minimum switching capacity | 4000 VA |
Maximum switching voltage | 250 V AC (External supply) |
Max. switching current | 16 A |
Switching | |
Output name | Motor switching output |
Maximum switching voltage | 12 V (Internal supply) |
Max. switching current | 1 A (maximum) |
Conductor connection | |
Connection method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 4 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor connection | |
Connection method | Screw connection |
Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1 mm² |
Conductor cross section AWG | 26 ... 16 |
Interface | Ethernet (1x) |
RS-485 | |
Interface | RS-485 2-wire |
Bus system | RS-485 |
Connection method | Screw connection |
Number of interfaces | 1 (for energy measurement device and RFID reader) |
Number of supported devices | 2 |
Transmission speed range | 4.8 kbps ... 115.2 kbps (adjustable) |
Protocols supported | Modbus/RTU (Master) |
Ethernet | |
Interface | Ethernet |
Connection method | RJ45 jack |
Number of interfaces | 1 |
Serial transmission speed | 10/100 Mbps |
Transmission length | 100 m |
Protocols supported | Modbus/TCP |
OCPP 1.6J |
Status display | 5 x LEDs |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | < 2000 m |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
Conformity/Approvals | |
Conformance | CE-compliant |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Noise immunity | EN 61000-6-2 |
Immunity to the discharge of static electricity | EN 61000-4-2: 8 kV air, 4 kV contact discharge |
Immunity to electromagnetic fields | EN 61 000-4-3, 80---1000 MHz, 10 V/m |
Immunity to conducted high frequency | EN 61 000-4-6, 0.15...80 MHz, 10 V |
Immunity to fast transients (Burst) | EN 61 000-4-4: 2 kV AC mains input, 1 kV data cable |
Housing | DIN 43880 |
Noise emission | EN 61000-6-3 |
Standards | |
Standards/regulations | IEC 61851-1 |
Mounting type | DIN rail mounting |
Mounting position | any |
Item number | 1139449 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | XWB |
Product key | XWBBCA |
GTIN | 4063151087715 |
Weight per piece (including packing) | 530.2 g |
Weight per piece (excluding packing) | 530.2 g |
Customs tariff number | 85371098 |
Country of origin | DE |
ECLASS
ECLASS-11.0 | 27144703 |
ECLASS-12.0 | 27144703 |
ECLASS-13.0 | 27144703 |
ETIM
ETIM 9.0 | EC002889 |
UNSPSC
UNSPSC 21.0 | 39121800 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes (No exemptions) |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-10
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | No substance above 0.1 wt% |
Compatible products
PHOENIX CONTACT s.r.o.
Námestie Mateja Korvína 1, 811 07 Bratislava. Zapísaná v Obchodnom registri Okresného súdu Bratislava III, vložka číslo 48994/B.