Conductor cross-section flexible (ferrule without plastic sleeve)
0.25 mm² ... 4 mm²
Flexible conductor cross-section (ferrule with plastic sleeve)
0.25 mm² ... 4 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)
0.5 mm² ... 2.5 mm²
2 conductors with same cross section, rigid
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG rigid
26 ... 16 (converted acc. to IEC)
2 conductors with same cross section, flexible
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG flexible
26 ... 16 (converted acc. to IEC)
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.25 mm² ... 1.5 mm²
Nominal current
15 A
Nominal voltage
320 V
Width
6.2 mm
Height
45.4 mm
Color
gray
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)
28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Mechanical data
Open side panel
No
Ambient conditions
Ambient temperature (operation)
-50 °C ... 100 °C
Ambient temperature (assembly)
-50 °C ... 100 °C
Mounting type
Insertion in base strip
Item number
3208619
Packing unit
50 pc
Minimum order quantity
1 pc
Note
Made to order (non-returnable)
Product key
BE643X
GTIN
4046356655187
Weight per piece (including packing)
9.07 g
Weight per piece (excluding packing)
9.07 g
Country of origin
PL
EU RoHS
Fulfills EU RoHS substance requirements
Yes
Exemption
6(c)
China RoHS
Environment friendly use period (EFUP)
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.