The DC/DC converters in the TRIO POWER family supply your system directly from the field and provide a reliable power supply even without a central grid. They are particularly well-suited for photovoltaic applications, where they also allow the central inverter to be started without a supplying grid.
TRIO-PS-2G/1500DC/24DC/1.5
-
Power supply
1107892
Primary-switched TRIO POWER DC/DC converter with Push-in connection for DIN rail mounting, input: 1,500 V DC, output: 24 V DC / 1.5 A
Product details
DC operation | |
Nominal input voltage range | 500 V DC ... 1500 V DC |
Input voltage range | 450 V DC ... 1650 V DC |
Wide-range input | no |
Electric strength, max. | ≤ 1800 V DC 1 s |
Typical national grid voltage | 500 V DC |
1500 V DC | |
Voltage type of supply voltage | DC |
Inrush current integral (I2t) | typ. 0.15 A2s |
Current consumption | typ. 85 mA (450 V DC) |
typ. 30 mA (1500 V DC) | |
Recommended breaker for input protection | 1 A (gPV) |
Recommended fuse for input protection | 1500 V DC |
Efficiency | typ. 88 % (500 V DC) |
typ. 87 % (900 V DC) | |
typ. 83 % (1500 V DC) | |
Nominal output voltage | 24 V DC ±3 % |
Nominal output current (IN) | 1.5 A |
Derating | > 60 °C ... 70 °C (2.5 %/K) |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | ≤ 30 V DC |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 40 mVPP (Ripple) |
< 50 mVPP (Noise) | |
Short-circuit-proof | yes |
No-load proof | yes |
Output power | 36 W |
Maximum no-load power dissipation | < 1.1 W (500 V DC) |
< 1.4 W (900 V DC) | |
< 2.4 W (1500 V DC) | |
Power loss nominal load max. | < 4.2 W (500 V DC) |
< 5.5 W (900 V DC) | |
< 7.5 W (1500 V DC) | |
Rise time | ≤ 30 ms (UOUT (10 % ... 90 %)) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | no |
Input | |
Connection method | Push-in connection |
Conductor cross section, rigid min. | 1 mm² |
Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 1 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 1 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 1 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Output | |
Connection method | Push-in connection |
Conductor cross section, rigid min. | 1 mm² |
Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 1 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 1 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 1 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 12 |
Stripping length | 10 mm |
Types of signaling | LED |
Signal output: LED status indicator | |
Signalization designation | DC OK |
Status display | "DC OK" LED green |
Note on status display | UOUT > 21.5 V: LED lights up |
Color | green |
DC OK | UOUT > 0.9 x UN (UN = 24 V DC) |
Number of phases | 1 |
Insulation voltage input/output | 4.2 kV DC (type test) |
2.6 kV DC (routine test) |
Product type | DC/DC converters |
Product family | TRIO POWER |
MTBF (IEC 61709, SN 29500) | > 3300000 h (25 °C) |
> 1760000 h (40 °C) | |
> 740000 h (60 °C) | |
Insulation characteristics | |
Protection class | II |
Degree of pollution | 2 |
Dimensional drawing |
|
Width | 48 mm |
Height | 130 mm |
Depth Device depth (DIN rail mounting) | 115 mm (Device depth (DIN rail mounting)) |
Installation dimensions | |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting type | DIN rail mounting |
Assembly note | alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | no |
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing material | Plastic |
Type of housing | Polycarbonate |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 11 ms, 15 g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz ... 150 Hz, 2.3g, 90 min. |
Standard - Electrical safety | EN 62109-1:2011 |
Standard – Safety extra-low voltage | IEC 62109-1:2011 (SELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Overvoltage category | |
IEC 62109-1 | II |
UL approvals | UL 62109-1:2014 |
UL 1741 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Noise immunity | EN 61000-6-2:2005 |
Conducted noise emission | |
Standards/regulations | EN 55016 |
EN 61000-6-4 (Class A) | |
Noise emission | |
Standards/regulations | EN 55016 |
EN 61000-6-4 (Class A) | |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Contact discharge | 4 kV (Test Level 2) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion A |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m (> Test intensity 3) |
Frequency range | 1 GHz ... 2.7 GHz |
Test field strength | 10 V/m (Test Level 2) |
Frequency range | 2.7 GHz ... 6 GHz |
Test field strength | 3 V/m (Test Level 1) |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | 4 kV (Test Level 4 - asymmetrical) |
Output | 4 kV (Test Level 4 - asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge) | |
Standards/regulations | EN 61000-4-5 |
Surge voltage load (surge) | |
Input | 3 kV (Test intensity >4 - symmetrical) |
4 kV (Test Level 4 - asymmetrical) | |
Output | 0.5 kV (Test Level 2 - symmetrical) |
1 kV (Test Level 2 - asymmetrical) | |
Comments | Criterion A |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
Input/Output | asymmetrical |
Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Voltage dips | |
Standards/regulations | EN 61000-4-11 |
Emitted interference | |
Standards/regulations | EN 61000-6-4 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class A industrial area of application |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class A industrial area of application |
Criteria | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Item number | 1107892 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | CMD |
Product key | CMDO43 |
GTIN | 4063151010546 |
Weight per piece (including packing) | 567.3 g |
Weight per piece (excluding packing) | 350 g |
Customs tariff number | 85044095 |
Country of origin | CN |
ECLASS
ECLASS-13.0 | 27040701 |
ETIM
ETIM 9.0 | EC002540 |
UNSPSC
UNSPSC 21.0 | 39121000 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-25
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
EF3.0 Climate Change | |
CO2e kg | 17.25 kg CO2e |
Compatible products
-
CBM E4 24DC/0.5-10A NO-R - Electronic circuit breaker 2905743
-
CBM E8 24DC/0.5-10A NO-R - Electronic circuit breaker 2905744
-
VIP-2/SC/PDM-2/24 - Potential distributors 2315269
-
VIP-3/PT/PDM-2/24 - Potential distributors 2903798
-
VAL-MS 1500DC-PV/2+V - Type 2 surge arrester 1033708
-
VAL-MB-T1/T2 1500DC-PV/2+V - Lightning/surge arrester type 1/2 2905641
Your advantages
Suitable for use in all photovoltaic systems with high input voltage due to conformity with standards UL 62109 and UL 1741
High system availability with a robust design that ensures partial discharge resistance
Direct, immediate supply from the solar field to supply the string monitoring function within string combiner boxes
Quick and easy installation with Push-in connection
PHOENIX CONTACT Middle East FZ LLC
1201N-1206N, Dubai Science Park Towers - North, P.O. Box 345002, Dubai, United Arab Emirates