cULus Recognized
Approval ID: E60425CSA
Approval ID: 13631| Nominal voltage UN | Nominal current IN | Cross section AWG | Cross section mm2 | |
|---|---|---|---|---|
| C | ||||
| 1000 V | 150 A | 14 - 1/0 | ||
High-current connector, nom. voltage: 1000 V, nominal current: 150 A, number of connections: 2, connection method: Bolt connection, Rated cross section: 50 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray
| General | |
| Note | The rated insulation voltage applies to insulated cable lugs acc. DIN 46237:1970-07 and for uninsulated cable lugs acc. DIN 46234:1980-03 with shrink sleeve. | 
| The rated insulation voltage applies to insulated cable lugs acc. DIN 46237:1970-07 and for uninsulated cable lugs acc. DIN 46234:1980-03 with shrink sleeve. When using uninsulated cable lugs with shrink sleeve the min. required air clearances and creepage distances have to be ensured by the enduser. | |
| The rated insulation voltage applies to insulated cable lugs acc. to DIN 46237:1970-07 and for uninsulated cable lugs acc. to DIN 46234:1980-03 with path extension. | |
| Product type | Bolt connection terminal block | 
| Product family | HV | 
| Number of connections | 2 | 
| Number of rows | 1 | 
| Potentials | 1 | 
| Insulation characteristics | |
| Overvoltage category | III | 
| Degree of pollution | 3 | 
| Rated surge voltage | 8 kV | 
| Maximum power dissipation for nominal condition | 4.06 W | 
| Number of connections per level | 2 | 
| Nominal cross section | 50 mm² | 
| Connection method | Bolt connection | 
| Stripping length | The stripping length depends on the specification provided by the cable lug manufacturer. | 
| Connection in acc. with standard | IEC 60947-7-1 | 
| Nominal current | 150 A | 
| Maximum load current | 150 A | 
| Nominal voltage | 1000 V | 
| Nominal cross section | 50 mm² | 
| Connection in acc. with standard | NF F61-017 | 
| Maximum total current | 101 A | 
| Nominal voltage | 1000 V | 
| Nominal cross section | 25 mm² | 
| Cable lug connection DIN 46234:1980-03 | |
| Connection in acc. with standard | DIN 46234:1980-03 | 
| Cross section | 2.5 mm² ... 50 mm² | 
| Cross section range AWG | 12 ... 2 (converted acc. to IEC) | 
| Hole diameter | 8.4 mm | 
| Width | 18 mm | 
| Bolt diameter | 8 mm | 
| Screw thread | M8 | 
| Tightening torque | 14.40 Nm | 
| Connection in acc. with standard | DIN 46235:1983-07 | 
| Cross section | 16 mm² ... 35 mm² | 
| Cross section range AWG | 6 ... 2 (converted acc. to IEC) | 
| Hole diameter | 8.4 mm | 
| Width | 20 mm | 
| Bolt diameter | 8 mm | 
| Screw thread | M8 | 
| Tightening torque | 14.40 Nm | 
| Connection in acc. with standard | DIN 46237:1970-07 | 
| Cross section | 2.5 mm² ... 6 mm² | 
| Cross section range AWG | 12 ... 8 (converted acc. to IEC) | 
| Hole diameter | 8.4 mm | 
| Width | 14 mm | 
| Bolt diameter | 8 mm | 
| Screw thread | M8 | 
| Tightening torque | 14.40 Nm | 
| Connection in acc. with standard | NF F00-363:1995-12-01 | 
| Cross section | ... 50 mm² | 
| Additional text | The stripping length is based on the specifications of the cable lug manufacturer. | 
| Cross section range AWG | (converted acc. to IEC) | 
| Bolt diameter | 6 mm | 
| Screw thread | M8 | 
| Tightening torque | 14.40 Nm | 
| Connection in acc. with standard | NF F00-363 | 
| Cross section | 0.5 mm² ... 25 mm² | 
| Additional text | Release list on request | 
| Cross section range AWG | (converted acc. to IEC) | 
| Width | 21 mm | 
| Height | 68 mm | 
| Depth | 65.1 mm | 
| Depth on NS 35/7,5 | 65.8 mm | 
| Depth on NS 35/15 | 73.3 mm | 
| Bolt length | 32.5 mm | 
| Color | gray (RAL 7042) | 
| Flammability rating according to UL 94 | V0 | 
| Insulating material group | I | 
| Insulating material | PA | 
| Static insulating material application in cold | -60 °C | 
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C | 
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 | 
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 | 
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 | 
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 | 
| Surface flammability NFPA 130 (ASTM E 162) | passed | 
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed | 
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed | 
| Surge voltage test | |
| Result | Test passed | 
| Temperature-rise test | |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K | 
| Result | Test passed | 
| Short-time withstand current 50 mm² | 6 kA | 
| Result | Test passed | 
| Power-frequency withstand voltage | |
| Test voltage setpoint | 2.2 kV | 
| Result | Test passed | 
| Mechanical data | |
| Open side panel | No | 
| Mechanical strength | |
| Result | Test passed | 
| Attachment on the carrier | |
| Result | Test passed | 
| Test for conductor damage and slackening | |
| Rotation speed | 10 (+/- 2) rpm | 
| Revolutions | 135 | 
| Conductor cross-section/weight | 50 mm² / 9.5 kg | 
| Result | Test passed | 
| Needle-flame test | |
| Time of exposure | 30 s | 
| Result | Test passed | 
| Oscillation/broadband noise | |
| Specification | DIN EN 50155 (VDE 0115-200):2022-06 | 
| Spectrum | Long life test category 2, bogie-mounted | 
| Frequency | f1 = 5 Hz to f2 = 250 Hz | 
| ASD level | 6.12 (m/s²)²/Hz | 
| Acceleration | 3.12g | 
| Test duration per axis | 5 h | 
| Test directions | X-, Y- and Z-axis | 
| Result | Test passed | 
| Shocks | |
| Pulse shape | Half-sine | 
| Acceleration | 30g | 
| Shock duration | 18 ms | 
| Number of shocks per direction | 3 | 
| Test directions | X-, Y- and Z-axis (pos. and neg.) | 
| Result | Test passed | 
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) | 
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) | 
| Ambient temperature (assembly) | -5 °C ... 70 °C | 
| Ambient temperature (actuation) | -5 °C ... 70 °C | 
| Permissible humidity (operation) | 20 % ... 90 % | 
| Permissible humidity (storage/transport) | 30 % ... 70 % | 
| Connection in acc. with standard | IEC 60947-7-1 | 
| NF F61-017 | 
| Mounting type | NS 35/7,5 | 
| NS 35/15 | 
| Item number | 1055644 | 
| Packing unit | 25 pc | 
| Minimum order quantity | 25 pc | 
| Note | Made to order (non-returnable) | 
| Sales key | ***** | 
| Product key | BE4212 | 
| GTIN | 4055626692753 | 
| Weight per piece (including packing) | 142.552 g | 
| Weight per piece (excluding packing) | 142.552 g | 
| Customs tariff number | 85369010 | 
| Country of origin | CN | 
| ECLASS-13.0 | 27250101 | 
| ECLASS-15.0 | 27250101 | 
| ETIM 9.0 | EC000897 | 
| UNSPSC 21.0 | 39121400 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes (No exemptions) | 
| China RoHS | |
| Environment friendly use period (EFUP) | 
              EFUP-E
               No hazardous substances above the limits 
             | 
          
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | No substance above 0.1 wt% |