Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
Signal conditioners and measuring transducers for standard applications
Signal conditioners and measuring transducers isolate, convert, filter, and amplify signals as an interface between field and controller. MACX Analog und MINI Analog Pro offer flexible solutions for AI, AO, DI, temperature, frequency, and limit values. MINI Analog Pro is a user-friendly and space-saving product family. MACX Analog guarantees the safety of people, the environment, and the system with functional safety.
Universally configurable temperature limit value switch with N/O relay output for the connection of 2, 3, and 4-conductor resistance thermometers and thermocouples. Configurable via DIP switch or software. Push-in connection technology
MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0 V ... 10 V, output signal: 0 mA ... 20 mA
Input loop-powered passive isolator with increased isolating voltage for electrical isolation of 0 mA/4 mA ... 20 mA signals. Input signal = output signal. number of channels: 2, Standard configuration, Loop-powered, 2-way isolation, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection
2-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
3-way output signal conditioner for transmitting 0/4 ... 20 mA signals from the controller to a load located in the field with simultaneous 3-way electrical isolation between the input, output, and supply, with screw connection
Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, screw connection.
NAMUR isolation switch amplifier for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive).. number of channels: 1, Standard configuration, 3-way isolation, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 2, Systematic Capability: 3, Push-in connection
Repeater power supply for supplying 2- and 4-conductor transmitters with Hart transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), screw connection
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.
Your advantages with our highly compact MINI Analog Pro signal conditioners
- Easy installation with easily accessible terminal points, power bridging, and plug-in connection terminal blocks; also with Push-in connection technology
- Easy startup and servicing: measure signals without disconnecting current loops, plus optional disconnect function
- Wide range of parameterization options: easy configuration via DIP switches as well as advanced configuration via software or smartphone app without additional accessories
- Service-friendly with large-surface marking areas, status LEDs in every signal conditioner, and group error indication
- The highly compact MINI Analog Pro signal conditioners with plug-in connection technology are part of the COMPLETE line system
Easy installation and startup
1. Easy installation:
Clearly visible and easily accessible terminal points and FASTCON Pro plug-in connection terminal blocks.
2. Easy startup and servicing:
Interrupt signal and supply circuits in no time at all with the integrated disconnect function.
3. Measure current signals easily:
Measure current signals during operation, without disconnecting the current loop.
4. Wide range of parameterization options:
Easy configuration via DIP switches as well as advanced configuration via software or smartphone app without additional accessories.
MINI Analog Pro signal conditioners feature easy installation and startup
Highly compact MINI Analog Pro signal conditioners: Safely isolated from the field to the network
Modular signal conditioner combination with plug-in gateways
Safely isolated from field to network
The easy-to-attach gateways allow you to integrate any MINI Analog Pro signal conditioner with current or digital output into your network in a space-saving way. Signal-specific input cards are no longer required. MINI Analog Pro gateways for bus and network connection are available for the following protocols:
- PROFINET
- Modbus/RTU
- Modbus/TCP
- PROFIBUS DP
Your advantages with the gateways for bus and network communication
- Space-saving network integration of freely combinable signal conditioners with compact plug-in gateways
- Interference-free signal transmission to the CPU with safe electrical isolation, even between the individual channels
- Cost and space savings at control level, because signal-specific input cards are no longer required
- Easy startup and servicing: measure current signals during operation or read them off on your smartphone via NFC