VAL-MS-T1/T2 48/12.5/O
   - 
  Lightning/surge arrester type 1/2
    
      2906281
      
      
    
  
      Universal varistor-based plug-in lightning/surge arrester for 1-phase power supply networks with common N and PE (2-conductor system: L1, PEN), with remote indication contact.
Product details
| Product type | Arrester combination | 
| Product family | VALVETRAB MS | 
| IEC test classification | I / II | 
| T1 / T2 | |
| I | |
| EN type | T1 / T2 | 
| IEC power supply system | DC | 
| Type | DIN rail module, two-section, divisible | 
| Number of positions | 1 | 
| Surge protection fault message | Optical, remote indicator contact | 
| Insulation characteristics | |
| Pollution degree | 2 | 
| Nominal frequency fN | 50 Hz (60 Hz) | 
| Connection method | Screw connection | 
| Screw thread | M5 | 
| Tightening torque | 4.5 Nm | 
| 30 lbf-in. (UL) | |
| Stripping length | 16 mm | 
| Conductor cross-section flexible | 1.5 mm² ... 25 mm² | 
| Conductor cross-section rigid | 1.5 mm² ... 35 mm² | 
| Conductor cross-section AWG | 15 ... 2 | 
| 10 ... 2 (UL) | 
| Dimensional drawing | 
                 | 
            
| Width | 17.5 mm | 
| Height | 77.1 mm | 
| Depth | 89.2 mm | 
| Horizontal pitch | 1 Div. | 
| Color | black (RAL 9005) | 
| Flammability rating according to UL 94 | V0 | 
| Housing material | PBT | 
| Mechanical data | |
| Open side panel | No | 
| Mode of protection | L-PEN | 
| (L+) - (L-) | |
| (L-) - PE | |
| (L+) - PE | |
| Direction of action | L-N / L-PEN | 
| Nominal voltage UN | -48 V DC (RRH) | 
| 60 V DC | |
| Nominal frequency fN | 50 Hz (60 Hz) | 
| Maximum continuous operating voltage UC | 75 V AC | 
| 100 V DC | |
| Rated load current IL | 80 A | 
| 80 A | |
| Protective conductor current IPE | ≤ 0.6 mA | 
| ≤ 0.6 mA | |
| Standby power consumption PC | ≤ 45 mVA | 
| ≤ 45 mVA | |
| Nominal discharge current In (8/20) µs | 12.5 kA | 
| Maximum discharge current Imax (8/20) µs | 30 kA | 
| Impulse discharge current (10/350) µs, charge | 6.25 As | 
| Impulse discharge current (10/350) µs, specific energy | 39 kJ/Ω | 
| Impulse discharge current (10/350) µs, peak value limp | 12.5 kA | 
| 12.5 kA | |
| Impulse discharge current (10/350) µs (L-N), charge | 6.25 As | 
| 6.25 As | |
| Impulse discharge current (10/350) µs (L-N), specific energy | 39 kJ/Ω | 
| 39 kJ/Ω | |
| Impulse discharge current (10/350) µs (L-N), peak current value Iimp | 12.5 kA | 
| 12.5 kA | |
| Short-circuit current rating ISCCR | 25 kA | 
| Voltage protection level Up | ≤ 0.4 kV | 
| Voltage protection level Up (L-N) | ≤ 0.4 kV | 
| Voltage protection level Up (L-PEN) | ≤ 0.4 kV | 
| Residual voltage Ures | ≤ 0.4 kV (at In) | 
| ≤ 0.35 kV (at 10 kA) | |
| ≤ 0.3 kV (at 5 kA) | |
| ≤ 0.275 kV (at 4 kA) | |
| ≤ 0.25 kV (at 3 kA) | |
| TOV behavior at UT | 100 V AC (5 s / withstand mode) | 
| 130 V DC (5 s / withstand mode) | |
| Response time tA | ≤ 25 ns | 
| Response time tA (L-N) | ≤ 25 ns | 
| Response time tA (L-PEN) | ≤ 25 ns | 
| Max. backup fuse with V-type through wiring | 80 A AC (gG - 16 mm²) | 
| 80 A AC (gG - 16 mm²) | |
| Max. backup fuse with branch wiring | 160 A AC (gG) | 
| 160 A AC (gG) | |
| Additional technical data | |
| Maximum discharge current Imax (8/20) µs | 65 kA | 
| Ambient conditions | |
| Degree of protection | IP20 (only when all terminal points are used) | 
| Ambient temperature (operation) | -40 °C ... 80 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 80 °C | 
| Altitude | max. 2000 m | 
| Permissible humidity (operation) | 5 % ... 95 % | 
| Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) | 
| Vibration (operation) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) | 
| UL specifications | |
| Maximum continuous operating voltage MCOV | 75 V AC | 
| Maximum continuous operating voltage MCOV (L-N) | 75 V AC | 
| Maximum continuous operating voltage MCOV (L-G) | 75 V AC | 
| Maximum continuous operating voltage MCOV (L+) - (L-) | 100 V DC | 
| Maximum continuous operating voltage MCOV (L+/L-) - G | 100 V DC | 
| Voltage protection rating VPR | 400 V | 
| Voltage protection rating VPR (L-N) | 400 V | 
| Nominal discharge current In | 20 kA | 
| Nominal discharge current In (L-G) | 20 kA | 
| Nominal discharge current In (L+) - (L-) | 20 kA | 
| Mode of protection | L-L | 
| L-G | |
| (L+) - (L-) | |
| (L+) - G | |
| (L-) - G | |
| Nominal voltage | 60 V DC | 
| Power distribution system | Single phase | 
| Measured limiting voltage MLV | 1240 V | 
| Measured limiting voltage MLV (L-G) | 1240 V | 
| Measured limiting voltage MLV (L+) - (L-) | 1230 V | 
| SPD Type | 1CA | 
| UL connection data | |
| Tightening torque | 30 lbf-in. | 
| Conductor cross-section AWG | 10 ... 2 | 
| Air clearances and creepage distances | |
| Standards/regulations | EN 61643-11 / UL 840 | 
| Mounting type | DIN rail: 35 mm | 
| Item number | 2906281 | 
| Packing unit | 12 pc | 
| Minimum order quantity | 12 pc | 
| Sales key | 02 | 
| Product key | CL1151 | 
| GTIN | 4055626063065 | 
| Weight per piece (including packing) | 149.52 g | 
| Weight per piece (excluding packing) | 149 g | 
| Customs tariff number | 85363090 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27171201 | 
ETIM
| ETIM 9.0 | EC000381 | 
UNSPSC
| UNSPSC 21.0 | 39121600 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes (No exemptions) | 
| China RoHS | |
| Environment friendly use period (EFUP) | 
              EFUP-E
               No hazardous substances above the limits 
             | 
          
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | No substance above 0.1 wt% | 
Compatible products
- 
    
      
 - 
    
      
MPB F400X16/ 1GS - Wiring bridge 2818342
 - 
    
      
MPB F200X16/ 1GS - Wiring bridge 2818339
 - 
    
      
MPB 18/1-10/1.0.0 - Wiring bridge 2830443
 - 
    
      
MPB 18/4-12 - Wiring bridge 2809296
 - 
    
      
MPB 18/4- 8 - Wiring bridge 2809283
 - 
    
      
MPB 18/3- 6 - Wiring bridge 2809241
 - 
    
      
MPB 18/1-57 - Wiring bridge 2809238
 - 
    
      
MPB 18/1-12 - Wiring bridge 2748593
 - 
    
      
MPB 18/1- 9 - Wiring bridge 2748580
 - 
    
      
MPB 18/1- 8 - Wiring bridge 2748577
 - 
    
      
MPB 18/1- 6 - Wiring bridge 2748564
 - 
    
      
MPB 18/1- 4 - Wiring bridge 2809225
 - 
    
      
MPB 18/1- 3 - Wiring bridge 2809212
 - 
    
      
MPB 18/1- 2 - Wiring bridge 2809209
 - 
    
      
MPB 18/1- 7 BU - Wiring bridge 2856278
 - 
    
      
MPB 18/1- 8 BU - Wiring bridge 2858470
 - 
    
      
ZBN 18,LGS:ERDE - Marker for terminal blocks 2749589
 - 
    
      
ZBN 18,LGS:L1-N,ERDE - Marker for terminal blocks 2749576
 - 
    
      
ZBN 18:UNBEDRUCKT - Zack marker strip 2809128
 - 
    
      
DK-BIC-35 - Feed-through terminal block 2749880
 - 
    
      
B-STIFT - Marker pen 1051993
 - 
    
      
SZK PZ2 VDE - Screwdriver 1206463
 - 
    
      
VAL-MS-T1/T2 48/12.5 ST - Type 1/2 surge protection plug 2801242
 - 
    
      
VAL-MS-T1/T2 BE/O-FM - Type 2 surge protection base element 2905652
 
Your advantages
Rack-mount 2U panel applications
        Plug-in direction parallel to the conductor axis
        Versions with and without floating remote indication contact
        DIN rail mounting
        Accepts Type 1 and Type 2 VAL-MS plugs
        Coding when protective plug is inserted for the first time
        PHOENIX CONTACT S.A de C.V.
        
        Lago Alberto No. 319 - Piso 9, Colonia Granada, Alcaldía Miguel Hidalgo, México, Ciudad de México, C.P. 11520