The PSK RTU 50 is a data logger with integrated GSM/GPRS modem, 2 analog and 4 digital inputs, 2 digital outputs, 1 serial interface, and 1 Ethernet interface. Thanks to the innovative power management, the data logger can also be operated with batteries or solar cells.
PSK RTU 50
-
Data logger
2400018
Data logger with integrated GSM/GPRS modem, 2 analog and 4 digital inputs, 4 digital outputs, 1 serial interface, and 1 Ethernet interface
Free download available.
Downloads
Product details
Product type | Data logger |
Type | Stand-Alone |
Insulation characteristics | |
Protection class | II (plastic housing) |
Retentive data storage | 1 Mbyte |
IEC 61131 runtime system | |
Program memory | 832 kByte |
Power consumption | typ. 70 mW (min. 2.45 mW, max. 1.4 W) |
Maximum power dissipation for nominal condition | max. 0.12 W |
Supply | |
Supply voltage | 24 V DC |
Supply voltage range | 10 V DC ... 30 V DC |
Max. current consumption | 100 mA |
Typical current consumption | 5 mA |
Real-time clock | |
Realtime clock | Yes (battery-backed) |
Description realtime clock | ±9 s/m internal accumulator |
Analog: | |
Number of inputs | 2 |
A/D converter resolution | 12 bit |
Connection method | COMBICON connectors |
Connection technology | Screw connection |
Current input signal | 4 mA ... 20 mA |
Input resistance current input | 50 Ω (To ground) |
Digital: | |
Number of inputs | 4 |
Connection technology | COMBICON |
Digital: | |
Output name | Digital outputs |
Number of outputs | 2 (Relay output) |
Output voltage | max. 60 V DC |
Output current | max. 1 A |
Battery voltage | 3 V DC |
Battery capacity | 235 mAh |
Connection method | COMBICON |
Input/output, power supply | |
Connection method | Screw connection |
Conductor cross section, rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section, flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 14 |
Wireless | |
Interface description | GSM / GPRS |
Frequency range | 850 MHz ... 1900 MHz |
Number | 1 |
Connection method | SMA (female) |
Impedance | 50 Ω |
SIM Interface | 1.8 volt and 3 volt SIM card |
RS-232 | |
Transmission physics | TTL level |
No. of channels | 1 (IDE) |
RS-232/-485 | |
No. of channels | 1 |
Protocols supported | IEC 60870-5-101, Modbus/RTU, IEC 62056-21 |
Serial | |
Bus system | Others |
Note on the connection method | Special interface for VEGABAR 66 |
No. of channels | 1 |
Ethernet | |
Connection method | RJ45 |
No. of channels | 1 (Datawatt Network Application Protocol) |
Protocols supported | IEC 60870-5-104, Modbus TCP/IP, FTP |
File format/coding | Configuration protocol |
Width | 210 mm |
Height | 110 mm |
Depth | 45 mm |
Color | silver/black |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -20 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
Vibration (operation) | 5g |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN 61000-4-2/IEC 61000-4-2 EN 61000-4-2 (ESD) Criterion B, ±6 kV contact discharge, ±8 kV air discharge |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN 61000-4-3/IEC 61000-4-3 EN 61000-4-3 (radiated noise immunity) Criterion A, 10 V/m | |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst)EN 61000-4-4/IEC 61000-4-4 EN 61000-4-4 (EFT burst) Criterion B, Supply lines: ±2 kV, Signal/data lines: ±2 kV | |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN 61000-4-5/IEC 61000-4-5 EN 61000-4-5 (surge) Criterion B | |
Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interferenceEN 61000-4-6/IEC 61000-4-6 EN 61000-4-6 (line noise immunity) Criterion A, Test voltage 10 V | |
Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 EN 55011 (emitted interference) Class A | |
Noise emission | |
Standards/regulations | EN 61000-6-4 |
Mounting type | DIN rail mounting |
Item number | 2400018 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DREDZX |
Product key | DREDZX |
Catalog page | Page 207 (C-5-2019) |
GTIN | 4055626016429 |
Weight per piece (including packing) | 980 g |
Weight per piece (excluding packing) | 475 g |
Customs tariff number | 84715000 |
Country of origin | NL |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes (No exemptions) |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | No substance above 0.1 wt% |
Compatible products
Your advantages
Alarm inputs and switching outputs
Integrated GSM-/GPRS modem
LED diagnostic indicators
Low power consumption
Data logger, gateway, and alarm manager