The controllers of the PLCnext Control AXC F 1152 family for the Axioline I/O system are fast, robust, and easy to use. They were consistently designed for maximum performance, easy handling and use in harsh industrial environments.
AXC F 1152
-
Controller
1151412
Controller (SPS), PLCnext Control; Programming: High-level language and IEC 61131-3; Operating system: Yocto/Linux® (real-time); Programming tool: PLCnext Engineer, Eclipse®, Visual Studio®, MATLAB®/ Simulink®; Processor: Arm® Cortex®-A9, 1x 800 MHz; IoT connection: PROFICLOUD and every cloud via cloud connectors; Development process certified in accordance with IEC 62443-4-1, Product certified in accordance with IEC 62443-4-2 (Certification conditions see user documentation);.
Free download available.
Downloads
Product details
| Note on application | |
| Note on application | Only for industrial use |
| Product type | Controller |
| Product family | PLCnext Control |
| Type | modular |
| Special properties | Development process certified in accordance with IEC 62443-4-1 |
| Product certified in accordance with IEC 62443-4-2 Certification conditions see user documentation | |
| Insulation characteristics | |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Overvoltage category | II |
| Display | |
| Diagnostics display | no |
| Trusted Platform Module | TPM 1.2 |
| Flash memory | 512 Mbyte (internal flash memory) |
| SD card from Phoenix Contact (for external flash memory, see accessories) | |
| Retentive data storage | 48 kByte (NVRAM) |
| RAM | 512 Mbyte DDR3 SDRAM |
| IoT capability: PROFICLOUDIoT capability: PROFICLOUD | |
| IoT platform | PROFICLOUD |
| Supports cloud computing | yes |
| IoT capability: PROFICLOUDIoT capability: PROFICLOUD | |
| IoT platform | PROFICLOUD |
| Supports cloud computing | yes |
| IEC 61131 runtime system | |
| Program memory | 8 Mbyte |
| Data storage system | 12 Mbyte |
| Axioline | |
| Amount of process data | max. 1482 Byte (per station (total input and output data)) |
| max. 1024 Byte (Axioline F local bus (input)) | |
| max. 1024 Byte (Axioline F local bus (output)) | |
| Number of supported devices | max. 63 (per station) |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) |
| INTERBUS-Master | |
| Amount of process data (Axioline input/output data max.) | max. 1482 Byte (per station (total input and output data)) |
| Amount of process data (Axioline input data max.) | max. 1024 Byte (Axioline F local bus (input)) |
| Amount of process data (Axioline output data max.) | max. 1024 Byte (Axioline F local bus (output)) |
| PROFINET | |
| Device function | PROFINET controller, PROFINET device |
| Update rate | min. 1 ms (4 devices) |
| min. 4 ms (16 devices) | |
| Process data width | 64 Byte ... 512 Byte (PROFINET device) |
| Conformance Class | A |
| Number of supported devices | max. 16 (at PROFINET controller) |
| Supported functions | MRP FSU PROFINET controller |
| MRP PROFINET device | |
| Device ID | 0169hex |
| Vendor ID | 00B0hex |
| Function | |
| Diagnostics display | no |
| Redundancy function | yes |
| Note on redundancy function | applicative system redundancy, PN S2 (IO controller and IO device) |
| Safety function | no |
| Industrial cybersecurity | yes |
| Programming data | |
| Register length (master) | 1482 Byte |
| Functionality | |
| Programming languages supported | Symbolic flowchart (SFC) |
| Ladder diagram (LD) | |
| Function block diagram (FBD) | |
| Structured text (ST) | |
| C++ | |
| C# | |
| Java | |
| Python® | |
| Simulink® | |
| System requirements | |
| Application interface | OPC UA® |
| Maximum power dissipation for nominal condition | 5.6 W (5.6 W = 10.6 W - 5.0 W) |
| Real-time clock | |
| Realtime clock | yes |
| Description realtime clock | typ. 10 ppm, max. 20 ppm at 25°C |
| Potentials: Communications power UL feed-in (the supply of the Axioline F local bus UBus is generated from UL) | |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple (± 5 %)) |
| Current draw | max. 442 mA (with 1 A at UBus for the I/Os) |
| Current consumption | typ. 200 mA (without I/Os and UL = 24 V) |
| Power consumption | max. 10.6 W (with 1 A at UBus for the I/Os) |
| Protective circuit | Surge protection; electronic |
| Reverse polarity protection; electronic | |
| Potentials: Axioline F local bus supply (UBus) | |
| Supply voltage | 5 V DC (via bus base module) |
| Power supply unit | 1 A |
| Connection method | Push-in connection |
| Axioline F connector | |
| Connection method | Push-in connection |
| Conductor cross-section, rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross-section, flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross-section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Supported protocols | HTTP |
| HTTPS | |
| PROFINET | |
| Modbus/TCP (via corresponding library) | |
| Modbus/RTU (via corresponding library) | |
| EtherNet/IP (Adapter) | |
| CANopen® (via corresponding library) | |
| DALI (via corresponding library) | |
| DALI-2 (via corresponding app) | |
| HART (via corresponding library) | |
| IO-Link® (via corresponding library) | |
| MQTT (via corresponding app) | |
| OPC UA® Server | |
| OPC UA® Client (License required) | |
| DHCP (via corresponding library) | |
| SFTP | |
| SMTP (via corresponding library) | |
| SNTP (via corresponding library) | |
| SNMP (via corresponding library) | |
| DNS (via corresponding library) | |
| DNP3 (via corresponding library) | |
| IEC 60870-5-1 (via corresponding library) | |
| IEC 60870-5-104 (via corresponding library) | |
| IPsec | |
| syslog | |
| Web server | yes |
| Axioline F local bus | |
| Number of interfaces | 1 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Ethernet | |
| Bus system | RJ45 |
| Number of interfaces | 2 (Switched internally) |
| Connection method | RJ45 jack |
| Note on the connection method | Auto negotiation and autocrossing |
| Transmission speed | 10/100 Mbps (full duplex) |
| Transmission physics | Ethernet in RJ45 twisted pair |
| Transmission length | max. 100 m |
| Dimensional drawing |
|
| Width | 45 mm |
| Height | 126.93 mm |
| Depth | 75 mm |
| Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
| Color (Housing) | gray (RAL 7042) |
| Ambient conditions | |
| Degree of protection | IP20 (Manufacturers declaration, not evaluated by UL) |
| Ambient temperature (operation) | -25 °C ... 60 °C up to 2000 m above mean sea level (observe derating) |
| -25 °C ... 55 °C up to 3000 m above mean sea level (observe derating) | |
| 55 °C (with max. 1 A on UBus) | |
| 55 °C ... 60 °C (only in conjunction with an Axioline F power module AXL F PWR 1H (Item no. 2688297)) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (according to DIN EN 61131-2) |
| Shock (operation) | 30g (in accordance with EN 60068-2-27/IEC 60068-2-27) |
| Vibration (operation) | 5g (in accordance with EN 60068-2-6/IEC 60068-2-6) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
| UL, USA/Canada | |
| Identification | cULus |
| Certificate | E238705 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Electrostatic discharge (ESD)IEC 61000-4-2 Criterion B, ±6 kV contact discharge, ±8 kV air discharge |
| Immunity test in accordance with EN IEC 61000-6-2 Electromagnetic fieldsIEC 61000-4-3 Criterion A, Field intensity: 10 V/m | |
| Immunity test in accordance with EN IEC 61000-6-2 Fast transients (burst)IEC 61000-4-4 Criterion B, ±2 kV | |
| Immunity test in accordance with EN IEC 61000-6-2 Transient overvoltage (surge)IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1.0 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1.0 kV | |
| Immunity test in accordance with EN IEC 61000-6-2 Conducted interferenceIEC 61000-4-6 Criterion A, Test voltage 10 V | |
| Noise emission test in accordance with EN IEC 61000-6-4 Class A |
| Mounting type | DIN rail mounting |
| Item number | 1151412 |
| Packing unit | 1 pc |
| Minimum order quantity | 1 pc |
| Sales key | DRA |
| Product key | DRADAB |
| GTIN | 4063151149420 |
| Weight per piece (including packing) | 277.56 g |
| Weight per piece (excluding packing) | 223 g |
| Customs tariff number | 85371091 |
| Country of origin | DE |
ECLASS
| ECLASS-13.0 | 27242207 |
| ECLASS-15.0 | 27242207 |
ETIM
| ETIM 10.0 | EC000236 |
UNSPSC
| UNSPSC 21.0 | 32151700 |
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes |
| Exemption | 7(a), 7(c)-I |
| China RoHS | |
| Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| SCIP | 2418a98b-5b4d-41d2-9e52-7693084ccb5e |
Compatible products
-
PLCNEXT ENGINEER - Programming software 1046008
-
SD FLASH 2GB PLCNEXT MEMORY - Program/configuration memory 1043501
-
SD FLASH 8GB PLCNEXT MEMORY - Program/configuration memory 1061701
-
SD FLASH 16GB PLCNEXT MEM LIC - Program/configuration memory 1831737
-
SD FLASH 32GB PLCNEXT MEMORY LIC - Program/configuration memory 1151111
-
SD FLASH PLCNEXT MEMORY LIC CFG - Program/configuration memory 1308064
-
AXC F IL ADAPT - PLC extension module 1020304
-
AXL F PWR 1H - Feed-in module 2688297
-
PLCNEXT TECHNOLOGY TOOLCHAIN - Programming software 1639782
-
DAUM-WINDOWS-SERVICE - Software 1542953
-
AXL F BS BK - Bus connector 2701422
Your advantages
Real-time-capable Linux operating system for deterministic and reliable execution of time-critical processes
Supports numerous protocols such as: HTTP, HTTPS, FTP, OPC UA, SNTP, SNMP, SMTP, SQL, MySQL, DCP, etc. – for smooth communication with IT systems
Direct connection to the Proficloud, the PLCnext Store and any cloud platforms – for seamless IoT integration of your applications
Support for numerous fieldbus protocols (PROFINET, Modbus TCP/RTU, Ethernet/IP, etc.) for easy integration into existing automation technology systems and installations
Maximum design freedom thanks to the combination of classic PLC programming with modern high-level languages such as C++, C#, or Python
Meets the highest security requirements of industrial automation – for the protection of your applications and data
PHOENIX CONTACT Trading LLC
Twin Tower Building No. 3279, 6th Floor, King Abdullah Branch Road, Al Quds District, Riyadh 13214, Kingdom of Saudi Arabia, Short Address Code: RFQA3279