MACX MCR-EX-AP-RTD-RTD
-
Temperature measuring transducer
1291894
Ex i-Resistance isolator for intrinsically safe operation of Pt 100 resistance thermometers in 2, 3, or 4-conductor technology and resistance-type sensors. The values measured at the Ex i input are transmitted 1:1 to the non Ex i output. number of channels: 1, Standard configuration, 3-way isolation, Screw connection
Product details
Note on application | Accuracy, typically specified as a percentage of the basic measuring range at UN, 23°C |
Notes on operation | Installation conditions influence the ambient temperature. Please refer to the “Control cabinet installation instructions”. |
Notes on operation | Sensor set via DIP switches |
Notes on operation | 2-conductor comparison set via DIP switch ADJ |
Product type | Temperature transmitter |
Product family | MACX Analog |
No. of channels | 1 |
Electrical isolation | 3-way isolation |
Signal transmission behavior | In = Out |
Temperature coefficient, typical | ≤ 0.1 % (10 K) |
Reverse polarity protection | yes |
Electrical isolation Input/output IEC/EN 60079-11 | |
Standards/regulations | IEC/EN 60079-11 |
Rated insulation voltage | 375 VPP |
Electrical isolation Input/power supply IEC/EN 60079-11 | |
Standards/regulations | IEC/EN 60079-11 |
Rated insulation voltage | 375 VPP |
Electrical isolation Input/error message output IEC/EN 60079-11 | |
Standards/regulations | IEC/EN 60079-11 |
Rated insulation voltage | 375 VPP |
Electrical isolation Input/configuration interface IEC/EN 60079-11 | |
Standards/regulations | IEC/EN 60079-11 |
Rated insulation voltage | 375 VPP |
Electrical isolation Output 1/output 2 | |
Test voltage | 350 V (50 Hz, 60 s) |
Electrical isolation Output/supply | |
Test voltage | 350 V (50 Hz, 60 s) |
Electrical isolation Output/configuration interface | |
Test voltage | 350 V (50 Hz, 60 s) |
Electrical isolation Output/supply/error message output | |
Test voltage | 350 V (50 Hz, 60 s) |
Supply | |
Nominal supply voltage | 24 V DC |
Supply voltage range | 18 V ... 31.2 V |
Power dissipation | ≤ 600 mW |
Power consumption | ≤ 650 mW |
Measurement | |
Description of the input | intrinsically safe |
Sensor types (RTD) that can be used | Pt 100 |
Connection technology | 2-, 3-, 4-conductor |
Linear resistance measuring range | 18 Ω ... 391 Ω (Pt 100) |
Max. permissible overall conductor resistance | ≤ 50 Ω (per wire, 2-conductor circuit) |
≤ 100 Ω (per wire, 3-, 4-conductor circuit) |
Analog: Resistance thermometer | |
Output signal Voltage | 2 V DC (Nominal voltage) |
Output signal Current | 5 mA (Nominal current) |
Output signal Resistance | 400 Ω |
Output signal Resistance range | 18 Ω ... 391 Ω (Pt 100) |
Settling time | < 10 ms (10% ... 90%, multiplexer mode) |
Setting range | < 1 s (Input/output) |
Sensor input current | 200 µA ... 5 mA |
Connection technology | 2-, 3-, 4-conductor |
Signal: Error message output | |
Maximum switching voltage | 30 V |
Max. switching current | 100 mA |
Connection method | Screw connection |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Ex installation (EPL) | Gc |
Ex i circuits (EPL) | Ga |
Da | |
Ma | |
Safety data | |
Max. internal inductance Li | negligible |
Max. internal capacitance Ci | negligible |
Max. output voltage Uo | 6.5 V |
Max. output current Io | 16.5 mA |
Max. output power Po | 27 mW |
Safety-related maximum voltage Um | 253 V AC |
IIA (simple circuit): Max. external inductivity Lo / Max. external capacitance Co | 900 mH / 1000 µF |
IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co | 450 mH / 570 µF |
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co | 120 mH / 25 µF |
I (simple circuit): Max. external inductivity Lo / Max. external capacitance Co | 1000 mH / 1000 µF |
IIB/IIIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 100 mH / 5.3 µF, 20 mH / 6.9 µF, 2 mH / 11 µF, 0.5 mH / 15 µF |
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 50 mH / 1.1 µF, 5 mH / 1.7 µF, 1 mH / 2.3 µF, 0.2 mH / 3.4 µF |
Status display | Green LED (supply voltage) |
Red LED (line errors) |
Dimensional drawing |
|
Width | 17.5 mm |
Height | 112.5 mm |
Depth | 113.7 mm |
Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Flammability rating according to UL 94 | V0 |
Housing material | PA 6.6 |
Ambient conditions | |
Degree of protection | IP20 (Terminal blocks) |
IP30 (Housing) | |
Ambient temperature (operation) | -20 °C ... 70 °C (Stand-alone device: any mounting position) |
-20 °C ... 60 °C (Group assembly: vertical DIN rail without circulating air) | |
-20 °C ... 65 °C (Group assembly: vertical DIN rail with circulating air) | |
-20 °C ... 65 °C (Group assembly: horizontal DIN rail without circulating air) | |
-20 °C ... 70 °C (Group assembly: horizontal DIN rail with circulating air) | |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | ≤ 95 % (non-condensing) |
ATEX | |
Identification | II (1) G [Ex ia Ga] IIC |
II (1) D [Ex ia Da] IIIC | |
II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc | |
I (M1) [Ex ia Ma] I | |
IECEx | |
Identification | [Ex ia Ga] IIC |
[Ex ia Da] IIIC | |
Ex nA nC [ia Ga] IIC T4 Gc | |
[Ex ia Ma] I |
Electromagnetic compatibility | Tested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21 |
Electrical isolation | 3-way isolation |
Mounting type | NS 35/15, NS 35/7,5 |
Mounting position | vertical, horizontal |
Item number | 1291894 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DK121W |
Product key | DK121W |
GTIN | 4063151524333 |
Weight per piece (including packing) | 202,9 g |
Weight per piece (excluding packing) | 202,9 g |
Customs tariff number | 85437090 |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 27210129 |
ETIM
ETIM 9.0 | EC002919 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 6(c), 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead titanium zirconium oxide (CAS: 12626-81-2) |
Lead (CAS: 7439-92-1) | |
SCIP | 94c59bd9-d5b5-4802-8972-47743bc10e55 |
Compatible products
-
IFS-USB-PROG-ADAPTER - Programming adapter 2811271
-
MACX MCR-PTB - Power and error message module 2865625
-
MACX MCR-PTB-SP - Power and error message module 2924184
-
QUINT4-SYS-PS/1AC/24DC/2.5/SC - Power supply 2904614
-
ME 17,5 TBUS 1,5/ 5-ST-3,81 GY - DIN rail bus connector 1090049
-
ME-TBUS-A MC 1,5-2 - DIN rail bus connector 1351974
-
ME-TBUS-A IMC1,5-2 - DIN rail bus connector 1351982
-
MCR-DP - Separating plate 1430594
-
MPS-IH WH - Insulating sleeve 0201663
-
MPS-IH RD - Insulating sleeve 0201676
-
MPS-IH BU - Insulating sleeve 0201689
-
MPS-IH YE - Insulating sleeve 0201692
-
MPS-IH GN - Insulating sleeve 0201702
-
MPS-IH GY - Insulating sleeve 0201728
-
MPS-IH BK - Insulating sleeve 0201731
-
MPS-MT - Test plug 0201744
-
UC-EMLP (11X9) - Plastic label 0819291
-
UC-EMLP (11X9) YE - Plastic label 0822602
-
UC-EMLP (11X9) CUS - Plastic label 0824547
-
UC-EMLP (11X9) YE CUS - Plastic label 0824548
-
UC-EMLP (11X9) SR - Plastic label 0828094
-
UC-EMLP (11X9) SR CUS - Plastic label 0828098
-
US-EMLP (11X9) - Plastic label 0828789
-
US-EMLP (11X9) YE - Plastic label 0828871
-
US-EMLP (11X9) SR - Plastic label 0828872
-
LS-EMLP (11X9) WH - Device marker 0831678
-
LS-EMLP (11X9) SR - Device marker 0831705
-
LS-EMLP (11X9) YE - Device marker 0831732
-
SZS 0,6X3,5 - Screwdriver 1205053
PHOENIX CONTACT B.V.
Hengelder 56, 6902 PA Zevenaar, Postbus 246, 6900 AE Zevenaar