PLC-RSP- 12DC/21HC
   - 
  Relay module
    
      2912264
      
      
    
  
      PLC-INTERFACE for high continuous currents, consisting of PLC-BSP.../21 HC basic terminal block with spring-cage connection and plug-in miniature relay, for mounting on DIN rail NS 35/7,5, limiting continuous current up to 10 A, 1 changeover contact, input voltage 12 V DC
Product details
| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area | 
| Product type | Relay Module | 
| Product family | PLC-INTERFACE | 
| Application | High continuous currents | 
| Operating mode | 100% operating factor | 
| Mechanical service life | 3x 107 cycles | 
| Insulation characteristics: Standards/regulations | |
| Insulation | Safe isolation, reinforced insulation | 
| Overvoltage category | III | 
| Pollution degree | 2 | 
| Data management status | |
| Date of last data management | 12.09.2025 | 
| Maximum power dissipation for nominal condition | 0.4 W | 
| Standards/regulations | |
| Rated insulation voltage | 250 V AC | 
| Rated surge voltage | 6 kV | 
| Coil side | |
| Nominal input voltage UN | 12 V DC | 
| Input voltage range | 10.3 V DC ... 16.8 V DC | 
| Typical input current at UN | 33 mA | 
| Typical response time | 8 ms | 
| Typical release time | 10 ms | 
| Protective circuit | Reverse polarity protection; Polarity protection diode | 
| Freewheeling diode; Freewheeling diode | |
| Operating voltage display | Yellow LED | 
| Switching | |
| Contact switching type | 1 changeover contact | 
| Type of switch contact | Single contact | 
| Contact material | AgNi | 
| Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) | 
| Minimum switching voltage | 12 V AC/DC | 
| Limiting continuous current | 10 A | 
| 6 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.) | |
| Maximum inrush current | 30 A (300 ms) | 
| Min. switching current | 100 mA | 
| Interrupting rating (ohmic load) max. | 240 W (at 24 V DC) | 
| 58 W (at 48 V DC) | |
| 48 W (at 60 V DC) | |
| 50 W (at 110 V DC) | |
| 80 W (at 220 V DC) | |
| 2500 VA (for 250 V AC) | |
| Interrupting rating (ohmic load) max. bridged | 144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.) | 
| 1500 VA (for 250 V AC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.) | |
| Switching capacity | 2 A (at 24 V, DC13) | 
| 0.2 A (at 110 V, DC13) | |
| 6 A (at 24 V, AC15) | |
| Coil side | |
| Connection method | Spring-cage connection | 
| Stripping length | 8 mm | 
| Conductor cross-section rigid | 0.14 mm² ... 2.5 mm² | 
| Conductor cross-section flexible | 0.14 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 26 ... 14 | 
| Contact side | |
| Connection method | Spring-cage connection | 
| Stripping length | 8 mm | 
| Conductor cross-section rigid | 0.14 mm² ... 2.5 mm² | 
| Conductor cross-section flexible | 0.14 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 26 ... 14 | 
| Width | 14 mm | 
| Height | 80 mm | 
| Depth | 94 mm | 
| Color | green (RAL 6021) | 
| Flammability rating according to UL 94 (Housing) | V0 (Housing) | 
| Ambient conditions | |
| Degree of protection (Relay) | RT II (Relay) | 
| Degree of protection (Relay base) | IP20 (Relay base) | 
| Ambient temperature (operation) | -40 °C ... 60 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Standards/regulations | |
| Standards/regulations | IEC 60664 | 
| EN 50178 | |
| Mounting type | DIN rail mounting | 
| Assembly note | in rows with zero spacing | 
| Mounting position | any | 
| Item number | 2912264 | 
| Packing unit | 10 pc | 
| Minimum order quantity | 1 pc | 
| Note | Made to order (non-returnable) | 
| Product key | DK622A | 
| GTIN | 4046356050678 | 
| Weight per piece (including packing) | 64,16 g | 
| Weight per piece (excluding packing) | 64,16 g | 
| Country of origin | DE | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) | 
Compatible products
            Note: Applying some accessories below might limit this product.
          
          
        - 
    
      FBST 500-PLC RD - Continuous plug-in bridge 2966786
- 
    
      FBST 500-PLC BU - Continuous plug-in bridge 2966692
- 
    
      FBST 500-PLC GY - Continuous plug-in bridge 2966838
- 
    
      FBST 6-PLC RD - Single plug-in bridge 2966236
- 
    
      FBST 6-PLC BU - Single plug-in bridge 2966812
- 
    
      FBST 6-PLC GY - Single plug-in bridge 2966825
- 
    
      FBST 8-PLC GY - Single plug-in bridge 2967688
- 
    
      FBST 14-PLC BK - Single plug-in bridge 2967691
- 
    
      NS 35/ 7,5 PERF 2000MM - DIN rail perforated 0801733
- 
    
      NS 35/ 7,5 CU UNPERF 2000MM-VPE 10 - DIN rail, unperforated 0801762
- 
    
      NS 35/15 CU UNPERF 2000MM-VPE 10 - DIN rail, unperforated 1201895
- 
    
      NS 35/15-2,3 UNPERF 2000MM-VPE 10 - DIN rail, unperforated 1201798
- 
    
      NS 35/15 AL UNPERF 2000MM - DIN rail, unperforated 1201756
- 
    
      ZB10/WH-100:UNBEDRUCKT - Zack marker strip 5060883
- 
    
      ZB 10:UNBEDRUCKT - Zack marker strip 1053001
- 
    
      PLC-ATP BK - Separating plate 2966841
- 
    
      PLC-ESK GY - Power terminal block 2966508
- 
    
      SZF 1-0,6X3,5 - Screwdriver 1204517
- 
    
      REL-MR- 12DC/21HC - Single relay 2961309
- 
    
      REL-MR- 12DC/21HC - Single relay 2961309
Your advantages
Efficient connection to system cabling using V8 adapter
        Long electrical service life thanks to 16 A relay
        All common input voltages of 12 V DC ... 230 V AC
        Safe isolation between coil and contact side
        Functional plug-in bridges
        Max. continuous current of 10 A
        PHOENIX CONTACT B.V.
        
        Hengelder 56, 6902 PA Zevenaar, Postbus 246, 6900 AE Zevenaar