The CATAN C1 EN controller is the central component of the Catan product family for building and room automation. The compact REG housing with an overall width of just 6 HP fits in all electrical distributors. The highly flexible mix of inputs and outputs leads to further space and cost savings. Each channel can be configured individually: universal inputs are suitable for temperature sensors, 0 V ... 10 V interfaces, or as meters, among other things. Alternatively, outputs can be configured as digital inputs. The controller is equipped with a managed switch (3 x 1 Gbps). Emalytics and the Niagara Framework are a powerful tool available as the programming environment. This makes it possible to integrate protocols such as BACnet, KNX, Modbus, and much more, and provides functions from room automation to HVAC and visualization. Easy cloud integration is possible as a building IoT controller.
CATAN C1 EN
-
Controller
1371432
Controller for building automation. 14 configurable inputs and outputs. Interfaces: 3 x Ethernet, 2 x RS-485, 2 x USB-C, TP for room automation, 2 x SPE for Catan extension modules. Local override operation via Catan Control Panel.
Free download available.
Downloads
Product details
Note on application | |
Note on application | Only for industrial use |
Product type | Controller |
Product family | Catan |
Installation location | indoor use |
Insulation characteristics | |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Trusted Platform Module | TPM 2.0 |
Processor | Arm®Cortex®-A53, 4x 1600 MHz |
Retentive data storage | 5 GByte (eMMC) |
512 kByte (MRAM, additional memory) | |
RAM | 1024 Mbyte (LPDDR4-RAM) |
Functionality | |
Programming languages supported | Niagara Framework® |
System requirements | |
Engineering tool | Emalytics |
Test voltage: Extension bus/communications | 500 V AC, 50 Hz, 1 min |
Test voltage: Logic/functional ground | 500 V AC, 50 Hz, 1 min |
Test voltage: LAN / logic | 500 V AC, 50 Hz, 1 min |
Test voltage: TP / logic | 500 V AC, 50 Hz, 1 min |
Test voltage: RS-485 / logic | 500 V AC, 50 Hz, 1 min |
Supply | |
Supply voltage (DC) | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Max. current consumption | max. 3.6 A |
Typical current consumption | 350 mA (without external load) |
400 mA (with display) | |
Current carrying capacity (Terminal points) | 13.5 A |
Current carrying capacity (Pass-through between the terminal points) | 4 A |
Real-time clock | |
Realtime clock | integrated (capacitive buffering) |
Analog: Universal input | |
Input name | Analog current inputs |
Current input signal | 0 mA ... 20 mA |
4 mA ... 20 mA | |
Protective circuit | Surge protection |
Analog: Universal input | |
Input name | Analog voltage inputs |
Voltage input signal | 0 V ... 10 V |
Input resistance of voltage input | > 5 MΩ |
Protective circuit | Surge protection |
Digital: Universal input | |
Input name | Digital inputs |
Description of the input | EN 61131-2 type 2 and 3 |
Input voltage range "0" signal | -3 V DC ... 5 V DC (An open input always provides a 0 signal.) |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Nominal input voltage UIN | 24 V DC |
Digital: Universal input | |
Input name | Floating contacts |
Input information | Connect the contact to ground. |
Description of the input | Open/closed contact |
Digital: Digital input (DOI) | |
Input name | “Digital input” function |
Input information | Connect the contact to ground. |
Recommendation: If you use sensitive contacts such as reed contacts, connect a series resistor of at least 100 Ω in series. | |
Connection method | Push-in connection |
Connection technology | 2-conductor |
Digital: Universal output | |
Input name | Digital inputs |
Input information | You can parameterize each universal output as a digital input. See ““Digital input” function” table. |
Analog | |
Input name | Analog temperature inputs |
Sensor types (RTD) that can be used | Pt 1000 |
Analog | |
Input name | Analog temperature inputs |
Sensor types (RTD) that can be used | Ni 1000, LG-Ni 1000 |
Analog | |
Input name | Analog temperature inputs |
Sensor types that can be used (TC) | NTC 10k, NTC 20k, NTC 10 k Pre |
Analog | |
Input name | Analog resistance inputs |
Analog | |
Input name | Analog resistance inputs |
Counter: Universal input | |
Input name | Counter inputs |
Input frequency | max. 20 Hz (Signal is debounced) |
Resolution | 1 Impulse |
Counter: Digital input (DOI) | |
Input name | Counter inputs |
Input frequency | max. 20 Hz (Signal is debounced) |
Resolution | 1 Impulse |
Analog: Universal output | |
Output name | Analog voltage outputs |
Voltage output signal | 0 V ... 10 V |
Digital: Digital output (DOI) | |
Output name | Digital outputs with “Digital input” function (DOI) |
Note on output | To obtain a valid voltage level for a logical "0" signal at the output, use a load resistor <1 kΩ. |
You can parameterize each digital output for the “Digital input” function. | |
Connection method | Push-in connection |
Connection technology | 2-conductor |
Number of outputs | 4 |
Protective circuit | Short-circuit protection |
Overload protection | |
Protection against incorrect DC connection (max. 30 V) | |
Output current | max. 500 mA (per channel) |
Nominal output voltage | 24 V DC |
Output current when switched off | max. 1.4 mA |
Nominal load, ohmic | 12 W (48 Ω) |
Permissible cable length | max. 30 m (For compliance with the requirements in accordance with CE and to ensure compliance with the EMC Directive) |
Reverse voltage resistance to short pulses | Reverse voltage proof |
Behavior with overload | Auto restart |
Behavior at voltage switch-off | The output follows the power supply without delay |
Digital: Universal output | |
Output name | Digital outputs |
Note on output | The technical data is identical to the data of the digital outputs with “Digital input” function (DOI). |
Connections 1 ... 2 (TP bus connection) | |
Connection method | Bus connection terminal |
Note on the connection method | 4-conductor, 2-position |
Conductor cross section, rigid | 0.34 mm² ... 0.75 mm² |
Conductor cross section AWG | 22 ... 18 |
Connections 3 ... 62 (power supply, link bus, I/O) | |
Connection method | Push-in connection |
Conductor cross section, flexible | 0.5 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Stripping length | 10 mm |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² (Conductor connection with open terminal point) |
0.34 mm² ... 1.5 mm² (Push-in connection) | |
Nominal cross section | 1.5 mm² |
Bus for room automation | |
Number of interfaces | 1 |
Connection method | Bus connection terminal |
Transmission speed | 9600 bps |
Ethernet | |
Number of interfaces | 3 |
Connection method | RJ45 jack, shielded |
Transmission speed | 10/100/1000 Mbps |
RS-485 | |
Number of interfaces | 2 |
Connection method | Push-in connection |
Extension bus (link bus) | |
Number of interfaces | 2 (for extension modules) |
Connection method | Push-in connection |
Note on the connection method | Single Pair Ethernet (SPE) 10BASE-T1L, shielded |
Transmission speed | 10 Mbps |
Transmission length | max. 350 m (between two devices) |
USB | |
Number of interfaces | 2 (Use as connection for Catan control panel and I/O devices, USB1 can also be used as a USB Ethernet gadget) |
Connection method | USB 2.0 full speed, socket type C |
Transmission speed | max. 12 Mbps |
Dimensions without display connected | |
Width | 89.7 mm |
Height | 60.7 mm |
Length | 107.6 mm |
Dimensions with display connected | |
Width | 89.7 mm |
Height | 68 mm |
Length | 107.6 mm |
Dimensional drawing |
|
Width | 89.7 mm |
Height | 60.7 mm |
Length | 107.6 mm |
Color (Lower housing part) | gray (RAL 7042) |
Color (Upper housing part) | light gray (RAL 7035) |
Material () | Polycarbonate (Housing) |
Flammability rating according to UL 94 | V0 |
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6 | : 5g |
Shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 30g |
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 10g |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -5 °C ... 50 °C (up to 3000 m above mean sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above mean sea level) |
Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
Electromagnetic compatibility | Conformance with EMC directive |
Conformance with EMC directives | Immunity test in accordance with EN IEC 63044-5-2 Transient overvoltage (surge) Criterion B |
Immunity test in accordance with EN IEC 63044-5-2 Fast transients (burst) Criterion A, ±500 V,Criterion B, ±1000 V | |
Immunity test in accordance with EN IEC 63044-5-2 Electromagnetic fields Criterion A, Field intensity: 10 V/m | |
Immunity test in accordance with EN IEC 63044-5-2 Electrostatic discharge (ESD) Criterion A, ±4 kV contact discharge, ±8 kV air discharge | |
Immunity test in accordance with EN IEC 63044-5-2 Conducted disturbance Criterion A, Test voltage 10 V | |
Noise emission test in accordance with EN IEC 63044-5-2 Class B |
Mounting type | DIN rail mounting (in accordance with DIN EN 60715) |
Mounting position | horizontal |
Alternative mounting positions are possible, but can lead to a reduction in thermal performance. |
Item number | 1371432 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DRHAFA |
Product key | DRHAFA |
GTIN | 4063151729899 |
Weight per piece (including packing) | 264,3 g |
Weight per piece (excluding packing) | 264,3 g |
Customs tariff number | 85371091 |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 27242207 |
ETIM
ETIM 9.0 | EC000236 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 6(c), 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead titanium zirconium oxide (CAS: 12626-81-2) |
Lead (CAS: 7439-92-1) |
Compatible products
-
CATAN DOR6 UI8 - Relay module 1371364
-
CATAN CONTROL PANEL - Display 1371366
-
CATAN DISPLAY MOUNT - Mounting kit 1478438
-
NBC-CATAN-UCML/2.0-PVC/UCFL - Extension cable 1665797
-
NBC-CATAN-UCML/5.0-PVC/UCFL - Extension cable 1665801
-
STEP3-PS/1AC/KNX/640/LPT - Bus power supply 1477019
-
NC4-CATAN-DEMO - Building management system 1764415
-
NC4-CATAN-50 - Building management system 1763886
-
NC4-CATAN-100 - Building management system 1763887
-
NC4-CATAN-250 - Building management system 1763888
-
NC4-CATAN-500 - Building management system 1764405
-
NC4-CATAN-1250 - Building management system 1764414
-
NC4-50-SMA-1YR - Building management system 1698090
-
NC4-50-SMA-3YR - Building management system 1698088
-
NC4-50-SMA-5YR - Building management system 1698087
-
NC4-100-SMA-1YR - Building management system 1101277
-
NC4-100-SMA-3YR - Building management system 1101283
-
NC4-100-SMA-5YR - Building management system 1101291
-
NC4-250-SMA-1YR - Building management system 2404204
-
NC4-250-SMA-3YR - Building management system 2404205
-
NC4-250-SMA-5YR - Building management system 2404206
-
NC4-500-SMA-1YR - Building management system 2404208
-
NC4-500-SMA-3YR - Building management system 2404209
-
NC4-500-SMA-5YR - Building management system 2404210
-
NC4-1250-SMA-1YR - Building management system 2404212
-
NC4-1250-SMA-3YR - Building management system 2404213
-
NC4-1250-SMA-5YR - Building management system 2404214
-
NC4-5000-SMA-1YR - Building management system 2404216
-
NC4-5000-SMA-3YR - Building management system 2404217
-
NC4-5000-SMA-5YR - Building management system 2404218
-
NC4-10000-SMA-1YR - Building management system 2404221
-
NC4-10000-SMA-3YR - Building management system 2404222
-
NC4-10000-SMA-5YR - Building management system 2404223
-
SUP-0 - Building management system 2404065
-
SUP-1 - Building management system 2404136
-
SUP-10 - Building management system 2404156
-
SUP-100 - Building management system 2404157
-
SUP-UNL - Building management system 2404158
-
SUP-0-SMA-1YR - Building management system 2404175
-
SUP-0-SMA-3YR - Building management system 2404176
-
SUP-0-SMA-5YR - Building management system 2404177
-
SUP-1-SMA-1YR - Building management system 2404179
-
SUP-1-SMA-3YR - Building management system 2404180
-
SUP-1-SMA-5YR - Building management system 2404181
-
SUP-10-SMA-1YR - Building management system 2404183
-
SUP-10-SMA-3YR - Building management system 2404184
-
SUP-10-SMA-5YR - Building management system 2404185
-
SUP-100-SMA-1YR - Building management system 2404187
-
SUP-100-SMA-3YR - Building management system 2404188
-
SUP-100-SMA-5YR - Building management system 2404189
-
SUP-UNL-SMA-1YR - Building management system 2404191
-
SUP-UNL-SMA-3YR - Building management system 2404192
-
SUP-UNL-SMA-5YR - Building management system 2404193
-
SUP-POINTS-500 - Building management system 2404159
-
SUP-POINTS-1250 - Building management system 2404160
-
SUP-POINTS-2500 - Building management system 2404161
-
SUP-POINTS-5000 - Building management system 2404162
-
SUP-POINTS-10000 - Building management system 2404163
-
SUP-UP-1 - Building management system 2404164
-
SUP-UP-100 - Building management system 2404165
-
SUP-UP-UNL - Building management system 2404166
-
POINTS-50 - Building management system 1101297
-
POINTS-100 - Building management system 1101298
-
POINTS-500 - Building management system 2404199
-
POINTS-1250 - Building management system 2404201
-
POINTS-2500 - Building management system 2404202
-
DR-S-DB-CSV - Building management system 2404169
-
DR-S-DB-MYSQL - Building management system 2404171
-
DR-S-DB-ORCL - Building management system 2404172
-
DR-S-DB-SQL - Building management system 2404173
-
OFFICE-DEMO-PC - Building management system 2404321
-
EM-VIEW-NDA-ENGINEERING - Building management system 1139368
-
PARTNER-ACCESS - Building management system 1139362
-
DR-S-JSON - Building management system 1231645
-
DR-JSON - Building management system 1439254
-
EMT (31X12,5)R - Insert label 0800008
-
NC4-50 - Building management system 1698091
Your advantages
Space and cost savings thanks to highly flexible I/O configurability
High-performance extension bus also enables distributed installation
Startup and maintenance with plug-in display for local operation
Support for all key building automation protocols
Software security with secure boot, signed software, and TPM-protected device identity
Effective engineering and visualization with Emalytics and the Niagara Framework
Digital twin as the basis for smart buildings
PHOENIX CONTACT B.V.