FL SWITCH 2406-2SFX PN
   - 
  Industrial Ethernet Switch
    
      1089126
      
      
    
  
      Managed Switch 2000 series, 6 RJ45 ports 10/100 Mbps, 2 SFP ports 100 Mbps, degree of protection: IP20, Ambient temperature (operation): -40 °C ... 70 °C, Supply voltage range: 19 V DC ... 32 V DC, PROFINET Conformance Class B, Extended temperature range, PROFINET mode preset, PROFINET status LEDs, Development process certified in accordance with IEC 62443-4-1, Compatible with IEC 62443-4-2
      Free download available.
      Downloads
    
  Product details
| Dimensional drawing | 
                 | 
            
| Width | 128 mm | 
| Height | 113 mm | 
| Depth | 67 mm | 
| General | Support by phone or on-site (fee is charged) | 
| Note on application | |
| Note on application | Only for industrial use | 
| Material base plate | Die-cast aluminum, corrosion-resistant | 
| Housing material | Stainless steel 1.4301 | 
| Mounting type | DIN rail mounting | 
| Ethernet (RJ45) | |
| Connection method | RJ45 | 
| Note on the connection method | Auto negotiation and autocrossing | 
| Transmission speed | 10/100 Mbps | 
| Transmission physics | Copper | 
| Transmission length | 100 m (per segment) | 
| Signal LEDs | Data receive, link status | 
| No. of channels | 6 (RJ45 ports) | 
| Ethernet (SFP) | |
| Number of interfaces | 2 | 
| Connection method | SFP | 
| Transmission speed | 100 Mbps (full duplex) | 
| Transmission physics | Depending on the SFP module | 
| Transmission length | up to 40 km (depending on the SFP module used) | 
| Signal LEDs | Data receive, link status | 
| No. of channels | 2 (SFP ports) | 
| Product type | Switch | 
| Product family | Managed Switch 2000 | 
| Type | Block design | 
| MTTF | 357.82 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) | 
| 191.24 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| 25.65 Years (SN 29500 standard, temperature 70°C, operating cycle 100%) | |
| Special properties | Extended temperature range | 
| PROFINET mode preset, PROFINET status LEDs | |
| Development process certified in accordance with IEC 62443-4-1 | |
| Compatible with IEC 62443-4-2 | |
| Signal delay | ≥ 6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) | 
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 | 
| Insulation characteristics | |
| Protection class | III (VDE 0106) | 
| Degree of pollution | 2 | 
| Switch functions | |
| Diagnostic functions | RMON History | 
| LLDP (Link Layer Discovery Protocol) | |
| SNMP-Traps | |
| N:1-Portmirroring | |
| ACD (Address Conflict Detection) | |
| SysLog | |
| CRC-Surveillance | |
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 | 
| Signal contact control voltage | typ. 24 V DC | 
| PROFINET conformance class | Conformance Class B | 
| PROFINET device function | PROFINET device | 
| Fast Startup | |
| Filter functions | Quality of Service (8 priority classes) | 
| Class of Service | |
| DiffServ/DSCP | |
| Port-Priorisierung | |
| VLAN (up to 32 VLANs) | |
| IGMP Snooping/Querier (v1/v2) | |
| Auto-Query-Port | |
| Extended Multicast Filtering | |
| IP parameterization | DHCP client | 
| DHCP Option 82 (Relay Agent) | |
| DHCP server (pool-based, port-based) | |
| BootP | |
| DCP (Discovery and Configuration Protocol) | |
| MAC address table | 8k | 
| Management | Web-based management (HTTP/HTTPS) | 
| Role-based user management (LDAP, RADIUS) | |
| SNMPv1/v2/v3 | |
| Command Line Interface (Telnet, SSH) | |
| Redundancy | MRP (Media Redundancy Protocol) | 
| RSTP (Rapid Spanning Tree Protocol) | |
| FRD (Fast Ring Detection) | |
| Large Tree Support | |
| LACP (Link Aggregation Control Protocol) | |
| PROFINET S2 system redundancy | |
| Status and diagnostic indicators | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF) | 
| Additional functions | Transmission of MMS and GOOSE (IEC 61850-8-1) | 
| Transmission of Modbus/TCP | |
| Time synchronization | SNTP (Simple Network Time Protocol) | 
| Security functions | |
| Port security | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass | 
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 | 
| Local diagnostics | US1/2 Supply voltage US1, US2 Green LED | 
| FAIL Div. LED red | |
| LNK/ACT Link status Green LED | |
| SPD Data transmission speed Green LED | |
| BF Bus errors LED red | |
| SF Group error LED red | |
| Maximum power dissipation for nominal condition | 4.7 W (US = max, Tamb = max) | 
| Test section | 24 V supply / functional ground 500 V DC 1 min | 
| Ethernet interface/all other potentials 2.25 kV DC 1 min | |
| Transmission medium | Copper | 
| FO | |
| Supply | |
| Supply voltage (DC) | 24 V DC (redundant) | 
| Supply voltage range | 19.2 V DC ... 32 V DC | 
| Power supply connection | Via COMBICON, max. conductor cross-section 2.5 mm² | 
| Residual ripple | 3.6 VPP (within the permitted voltage range) | 
| Max. current consumption | 250 mA (US = min, Tamb = max) | 
| Typical current consumption | 180 mA (at US = 24 V DC and 25 °C ambient temperature) | 
| Function | |
| Signal contact control voltage | typ. 24 V DC | 
| Connection method | Push-in spring connection | 
| Note on the connection method | Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C) | 
| Conductor cross-section, rigid | 0.2 mm² ... 1.5 mm² | 
| Conductor cross-section, flexible | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 24 ... 16 | 
| Stripping length | 10 mm | 
| Ambient conditions | |
| Degree of protection | IP20 | 
| Ambient temperature (operation) | -40 °C ... 70 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) | 
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | 
| Shock (operation) | 30g (EN 60068-2-27) | 
| Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz | 
| Air pressure (operation) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) | 
| Air pressure (storage/transport) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) | 
| Free from substances that could impair the application of coating | Yes | 
| UL, USA/Canada | |
| Identification | cULus | 
| Corrosive gas test | |
| Identification | ISA S71.04.2013 G3 Harsh Group A | 
| Shipbuilding data | |
| Temperature | B | 
| Humidity | B | 
| Vibration | A | 
| EMC | B | 
| Enclosure | Required protection according to the Rules shall be provided upon installation on board | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B | 
| EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A | |
| EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A | |
| EN 61000-6-2 EN 61000-4-5 (surge) Criterion A | |
| EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A | |
| EN 61000-6-2 EN 61000-6-4 (interference) Class A | |
| EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A | |
| Noise immunity | EN 61000-6-2 | 
| Noise emission | |
| Standards/regulations | EN 61000-6-4 | 
| Functionality | |
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 | 
| Status display | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF) | 
| Item number | 1089126 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Sales key | ***** | 
| Product key | DNN122 | 
| GTIN | 4055626892368 | 
| Weight per piece (including packing) | 786.1 g | 
| Weight per piece (excluding packing) | 650 g | 
| Customs tariff number | 85176200 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 19170401 | 
| ECLASS-15.0 | 19170401 | 
ETIM
| ETIM 9.0 | EC000734 | 
UNSPSC
| UNSPSC 21.0 | 43222600 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | 
              EFUP-50
               An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. 
             | 
          
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) | 
| SCIP | 637b635d-f0b8-4295-9fa7-2fc277b24ced | 
Compatible products
- 
    
      
SD FLASH 2GB - Program/configuration memory 2988162
 - 
    
      
FL NETWORK MANAGER BASIC - Network management software 2702889
 - 
    
      
FL DIN RA - DIN rail adapter 2891053
 - 
    
      
FL RJ45 PROTECT CAP - Dust protection 2832991
 - 
    
      
E/NS 35 N - End bracket 0800886
 - 
    
      
FL CAT5 PATCH 0,5 - Patch cable 2832263
 - 
    
      
FL CAT5 PATCH 1,0 - Patch cable 2832276
 - 
    
      
FL CAT5 PATCH 2,0 - Patch cable 2832289
 - 
    
      
NBC-R4AC-R4AC-IE8A/.../... - Patch cable 1411854
 - 
    
      
NBC-R4AC/10G-R4AC/10G-94F/2,0 - Patch cable 1408360
 - 
    
      
NBC-R4AC/10G-R4AC/10G-94F/3,0 - Patch cable 1408365
 - 
    
      
NBC-R4AC/1,0-93B/R4AC - Patch cable 1408968
 - 
    
      
NBC-R4AC/2,0-93B/R4AC - Patch cable 1408969
 - 
    
      
NBC-R4AC/5,0-93B/R4AC - Patch cable 1408970
 - 
    
      
FKCN 2,5/ 2-ST GY7035 BD:1-2 - PCB connector 1082048
 - 
    
      
FKCN 2,5/ 4-ST GY7035 BD:1-4 - PCB connector 1082059
 - 
    
      
FL SFP FX - Media module 2891081
 - 
    
      
FL SFP FX SM - Media module 2891082
 - 
    
      
FOC-LC:PA-SC:PA-OM2:D01/1 - FO patch cable 1115607
 - 
    
      
FOC-LC:PA-SC:PA-OM2:D01/2 - FO patch cable 1115605
 - 
    
      
FOC-LC:PA-LC:PA-OM2:D01/1 - FO patch cable 1115633
 - 
    
      
FOC-LC:PA-LC:PA-OM2:D01/2 - FO patch cable 1115634
 - 
    
      
FOC-LC:PA-ST:PA-OM2:D01/1 - Fiber optic cable 1115588
 - 
    
      
FOC-LC:PA-ST:PA-OM2:D01/2 - Fiber optic cable 1115587
 - 
    
      
FOC-LC:PA-SC:PA-OM4:D01/1 - FO patch cable 1115601
 - 
    
      
FOC-LC:PA-SC:PA-OM4:D01/2 - FO patch cable 1115600
 - 
    
      
FOC-LC:PA-LC:PA-OM4:D01/1 - FO patch cable 1115625
 - 
    
      
FOC-LC:PA-LC:PA-OM4:D01/2 - FO patch cable 1115624
 - 
    
      
FOC-LC:PA-LC:PA-OS2:D01/1 - FO patch cable 1115636
 - 
    
      
FOC-LC:PA-LC:PA-OS2:D01/2 - FO patch cable 1115629
 - 
    
      
FOC-LC:PA-ST:PA-OS2:D01/1 - FO patch cable 1115596
 - 
    
      
FOC-LC:PA-ST:PA-OS2:D01/2 - FO patch cable 1115595
 - 
    
      
FOC-LC:PA-SC:PA-OS2:D01/1 - FO patch cable 1115618
 - 
    
      
FOC-LC:PA-SC:PA-OS2:D01/2 - FO patch cable 1115617
 - 
    
      
VS-08-RJ45-5-Q/IP20 - RJ45 connector 1656725
 
Your advantages
MRP (client and manager)
        VLANs
        DHCP client, DHCP server (pool-based and port-based), DHCP option 82
        RSTP
        Ambient temperature -40 °C ... 70 °C
        Configuration memory
        Web-based management, SNMP
        PROFINET mode preset
        Frequently searched
PHOENIX CONTACT (Ireland) Ltd
        
        C6 The Exchange, Calmount Park, Ballymount, Dublin 12, D12 XE18, Ireland