EC-PC 6/ 3-ST-BUS
   - 
  Insulating part
    
      1044820
      
      
    
  
      Insulator cap, color: green, product range: EC-PC 6/..-ST-BUS, width: 36.4 mm
Product details
| Notes on operation | In accordance with IEC 61984, COMBICON connectors have no switching power (COC). During designated use, they must not be plugged in or disconnected when carrying voltage or under load. | 
| Product type | Insulator cap | 
| Product family | EC-PC 6/..-ST-BUS | 
| Product line | COMBICON Connectors L | 
| Number of positions | 3 | 
| Pitch | 0 mm | 
| Number of rows | 1 | 
| Properties | |
| Nominal current IN | 32 A | 
| Nominal voltage UN | 1000 V | 
| Contact resistance | 0.7 mΩ | 
| Rated voltage (III/3) | 1000 V | 
| Rated surge voltage (III/3) | 8 kV | 
| Rated voltage (III/2) | 1000 V | 
| Rated surge voltage (III/2) | 8 kV | 
| Rated voltage (II/2) | 1000 V | 
| Rated surge voltage (II/2) | 6 kV | 
| Dimensional drawing |  | 
| Pitch | 7.62 mm | 
| Width [w] | 36.4 mm | 
| Height [h] | 27.07 mm | 
| Length [l] | 13 mm | 
| Installed height | 27.07 mm | 
| Material data - contact | |
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 | 
| Contact material | Cu alloy | 
| Surface characteristics | hot-dip tin-plated | 
| Metal surface terminal point (top layer) | Tin (4 - 8 µm Sn) | 
| Metal surface contact area (top layer) | Tin (4 - 8 µm Sn) | 
| Material data - housing | |
| Color (Housing) | green (6021) | 
| Insulating material | PA | 
| Insulating material group | I | 
| CTI according to IEC 60112 | 600 | 
| Flammability rating according to UL 94 | V0 | 
| Glow wire flammability index GWFI according to EN 60695-2-12 | 850 | 
| Glow wire ignition temperature GWIT according to EN 60695-2-13 | 775 | 
| Temperature for the ball pressure test according to EN 60695-10-2 | 125 °C | 
| Connection 1 | |
| Insulating material | PA | 
| CTI according to IEC 60112 | 600 | 
| Thermal test | Test group C | |
| Specification | IEC 60512-5-1:2002-02 | 
| Tested number of positions | 3 | 
| Short-time withstand current | |
| Specification | IEC 60998-2-3:2002-12 | 
| Insulation resistance | |
| Specification | IEC 60512-3-1:2002-02 | 
| Insulation resistance, neighboring positions | > 5 MΩ | 
| Temperature cycles | |
| Specification | IEC 60998-2-3:2002-12 | 
| Result | Test passed | 
| Air clearances and creepage distances | | |
| Specification | IEC 60664-1:2007-04 | 
| Insulating material group | I | 
| Comparative tracking index (IEC 60112) | CTI 600 | 
| Rated insulation voltage (III/3) | 1000 V | 
| Rated surge voltage (III/3) | 8 kV | 
| minimum clearance value - non-homogenous field (III/3) | 8 mm | 
| minimum creepage distance (III/3) | 12.5 mm | 
| Rated insulation voltage (III/2) | 1000 V | 
| Rated surge voltage (III/2) | 8 kV | 
| minimum clearance value - non-homogenous field (III/2) | 8 mm | 
| minimum creepage distance (III/2) | 8 mm | 
| Rated insulation voltage (II/2) | 1000 V | 
| Rated surge voltage (II/2) | 6 kV | 
| minimum clearance value - non-homogenous field (II/2) | 5.5 mm | 
| minimum creepage distance (II/2) | 5.5 mm | 
| Conductor connection | |
| Specification | IEC 60998-2-3:2002-12 | 
| Result | Test passed | 
| Test for conductor damage and slackening | |
| Specification | IEC 60998-2-3:2002-12 | 
| Result | Test passed | 
| Repeated connection and disconnection | |
| Specification | IEC 60998-2-3:2002-12 | 
| Result | Test passed | 
| Pull-out test | |
| Specification | IEC 60998-2-3:2002-12 | 
| Conductor cross-section/conductor type/tractive force setpoint/actual value | 16 mm² / flexible / > 100 N | 
| Insertion and withdrawal forces | |
| Result | Test passed | 
| No. of cycles | 25 | 
| Insertion strength per pos. approx. | 13 N | 
| Withdraw strength per pos. approx. | 16 N | 
| Torque test | |
| Specification | IEC 60998-2-3:2002-12 | 
| Contact holder in insert | |
| Specification | IEC 60512-15-1:2008-05 | 
| Contact holder in insert Requirements >20 N | Test passed | 
| Resistance of inscriptions | |
| Specification | IEC 60068-2-70:1995-12 | 
| Result | Test passed | 
| Polarization and coding | |
| Specification | IEC 60512-13-5:2006-02 | 
| Result | Test passed | 
| Visual inspection | |
| Specification | IEC 60512-1-1:2002-02 | 
| Result | Test passed | 
| Dimension check | |
| Specification | IEC 60512-1-2:2002-02 | 
| Result | Test passed | 
| Vibration test | |
| Specification | IEC 60068-2-6:2007-12 | 
| Frequency | 10 - 150 - 10 Hz | 
| Sweep speed | 1 octave/min | 
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) | 
| Acceleration | 50 m/s² (60.1 Hz ... 150 Hz) | 
| Test duration per axis | 2.5 h | 
| Test directions | X-, Y- and Z-axis | 
| Durability test | |
| Specification | IEC 60512-9-1:2010-03 | 
| Impulse withstand voltage at sea level | 9.8 kV | 
| Contact resistance R1 | 0.7 mΩ | 
| Contact resistance R2 | 0.7 mΩ | 
| Insertion/withdrawal cycles | 25 | 
| Insulation resistance, neighboring positions | > 5 MΩ | 
| Climatic test | |
| Specification | ISO 6988:1985-02 | 
| Corrosive stress | 0.2 dm3 SO2 on 300 dm3/40 °C/1 cycle | 
| Thermal stress | 100 °C/168 h | 
| Power-frequency withstand voltage | 4.26 kV | 
| Glow-wire test | |
| Specification | IEC 60998-1:2002-12 | 
| Temperature | 850 °C | 
| Time of exposure | 5 s | 
| Glow-wire test | |
| Specification | IEC 60998-1:2002-12 | 
| Temperature | 650 °C | 
| Time of exposure | 5 s | 
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 100 °C (dependent on the derating curve) | 
| Ambient temperature (storage/transport) | -40 °C ... 70 °C | 
| Relative humidity (storage/transport) | 30 % ... 70 % | 
| Ambient temperature (assembly) | -5 °C ... 40 °C (Depending on the conductor insulation) | 
| Item number | 1044820 | 
| Packing unit | 25 pc | 
| Minimum order quantity | 25 pc | 
| Sales key | AAHZBK | 
| Product key | AAHZBK | 
| GTIN | 4055626633947 | 
| Weight per piece (including packing) | 2,798 g | 
| Weight per piece (excluding packing) | 2,758 g | 
| Customs tariff number | 85389099 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27460405 | 
| ECLASS-15.0 | 27460405 | 
ETIM
| ETIM 9.0 | EC002943 | 
UNSPSC
| UNSPSC 21.0 | 39121400 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes (No exemptions) | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-E No hazardous substances above the limits | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | No substance above 0.1 wt% | 
| EF3.0 Climate Change | |
| CO2e kg | 0,06 kg CO2e | 