The PLCnext Control AXC F 3152 for the Axioline I/O system is fast, robust, and easy to use. This means it is consistently designed for maximum performance, easy handling, and use in harsh industrial environments.
    
  
  AXC F 3152
   - 
  Controller
    
      1069208
      
      
    
  
      
      Free download available.
      Downloads
    
  Product details
| Note on application | |
| Note on application | Only for industrial use | 
| Product type | Controller | 
| Product family | PLCnext Control | 
| Type | modular | 
| Special properties | Development process certified in accordance with IEC 62443-4-1 | 
| Product certified in accordance with IEC 62443-4-2 Certification conditions see user documentation | |
| Insulation characteristics | |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) | 
| Overvoltage category | II | 
| Pollution degree | 2 | 
| Display | |
| Diagnostics display | no | 
| Trusted Platform Module | TPM 1.2 (to hardware version 03) | 
| TPM 2.0 (from hardware version 04) | |
| Flash memory | 1 GByte (internal flash memory) | 
| SD card from Phoenix Contact (for external flash memory, see accessories) | |
| Retentive data storage | 1 Mbyte | 
| RAM | 2048 Mbyte | 
| IoT capability: PROFICLOUDIoT capability: PROFICLOUD | |
| IoT platform | PROFICLOUD | 
| Supports cloud computing | yes | 
| IoT capability: PROFICLOUDIoT capability: PROFICLOUD | |
| IoT platform | PROFICLOUD | 
| Supports cloud computing | yes | 
| IEC 61131 runtime system | |
| Program memory | 12 Mbyte | 
| Data storage system | 32 Mbyte | 
| Axioline | |
| Amount of process data | max. 1482 Byte (per station (total input and output data)) | 
| max. 1024 Byte (Axioline F local bus (input)) | |
| max. 1024 Byte (Axioline F local bus (output)) | |
| Number of supported devices | max. 63 (per station) | 
| Number of local bus devices that can be connected | max. 63 (observe current consumption) | 
| PROFINET | |
| Device function | PROFINET controller, PROFINET device | 
| Update rate | min. 1 ms (32 participants) | 
| min. 2 ms (64 devices) | |
| min. 4 ms (128 participants) | |
| Conformance Class | B | 
| Number of supported devices | max. 128 (at PROFINET controller) | 
| Supported functions | FSU PROFINET controller | 
| Device ID | 0158hex | 
| Vendor ID | 00B0hex | 
| Function | |
| Diagnostics display | no | 
| Redundancy function | yes | 
| Note on redundancy function | Applicative system redundancy | 
| Safety function | no | 
| Note on the safety function | Functional safety is provided with the left-alignable AXC F XT SPLC 1000 or AXC F XT SPLC 3000 extension modules. | 
| Industrial cybersecurity | yes | 
| Functionality | |
| Programming languages supported | Symbolic flowchart (SFC) | 
| Ladder diagram (LD) | |
| Function block diagram (FBD) | |
| Structured text (ST) | |
| C++ | |
| C# | |
| Java | |
| Python® | |
| Simulink® | |
| System requirements | |
| Engineering tool | PLCnext Engineer | 
| Eclipse® | |
| Visual Studio® | |
| MATLAB®/ Simulink® | |
| Application interface | OPC UA® | 
| Maximum power dissipation for nominal condition | 10 W (10 W = 15 W - 5 W) | 
| Real-time clock | |
| Realtime clock | yes | 
| Description realtime clock | 0.7 s/day = 8 ppm at 25 °C | 
| Potentials: Communications power UL feed-in (the supply of the Axioline F local bus UBus is generated from UL) | |
| Supply voltage | 24 V DC | 
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple (± 5 %)) | 
| Current draw | max. 650 mA (with 1 A at UBus for the I/Os and UL = 24 V) | 
| Power consumption | typ. 15 W (with 1 A at UBus for the I/Os) | 
| Protective circuit | Surge protection; electronic | 
| Reverse polarity protection; electronic | |
| Potentials: Axioline F local bus supply (UBus) | |
| Supply voltage | 5 V DC (via bus base module) | 
| Power supply unit | 1 A | 
| Connection method | Push-in connection | 
| Axioline F connector | |
| Connection method | Push-in connection | 
| Conductor cross-section, rigid | 0.2 mm² ... 1.5 mm² | 
| Conductor cross-section, flexible | 0.2 mm² ... 1.5 mm² | 
| Conductor cross-section AWG | 24 ... 16 | 
| Stripping length | 8 mm | 
| Supported protocols | HTTP | 
| HTTPS | |
| PROFINET | |
| INTERBUS | |
| Modbus/TCP (via corresponding library) | |
| Modbus/RTU (via corresponding library) | |
| EtherNet/IP (Adapter) | |
| CANopen® (via corresponding library) | |
| DALI (via corresponding library) | |
| DALI-2 (via corresponding app) | |
| HART (via corresponding app) | |
| IO-Link® (via corresponding app) | |
| PROFIBUS | |
| MQTT (via corresponding app) | |
| OPC UA® Server | |
| OPC UA® Client (via corresponding app) | |
| DHCP (via corresponding app) | |
| SFTP | |
| SMTP (via corresponding app) | |
| SNTP (via corresponding app) | |
| SNMP (via corresponding app) | |
| DNS (via corresponding app) | |
| DNP3 (via corresponding app) | |
| IEC 60870-5-1 (via corresponding library) | |
| IEC 60870-5-104 (via corresponding library) | |
| IPsec | |
| syslog | |
| Web server | yes | 
| Axioline F local bus | |
| Number of interfaces | 1 | 
| Connection method | Bus base module | 
| Transmission speed | 100 Mbps | 
| Ethernet | |
| Bus system | RJ45 | 
| Number of interfaces | 3 | 
| Connection method | RJ45 jack | 
| Note on the connection method | Auto negotiation and autocrossing | 
| Transmission speed | 10/100/1000 Mbps | 
| Transmission physics | Ethernet in RJ45 twisted pair | 
| Transmission length | max. 100 m | 
| Service | |
| Bus system | USB | 
| Number of interfaces | 1 | 
| Connection method | USB type C | 
| Note on the connection method | Only device interface | 
| Dimensional drawing | 
                 | 
            
| Width | 100 mm | 
| Height | 126.93 mm | 
| Depth | 75 mm | 
| Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). | 
| Color (Housing) | gray (RAL 7042) | 
| Ambient conditions | |
| Degree of protection | IP20 (Manufacturers declaration, not evaluated by UL) | 
| Ambient temperature (operation) | -25 °C ... 60 °C up to 2000 m above mean sea level (observe derating) | 
| -25 °C ... 55 °C up to 3000 m above mean sea level (observe derating) | |
| 55 °C (with max. 1 A on UBus) | |
| 55 °C ... 60 °C (only in conjunction with an Axioline F power module AXL F PWR 1H (Item no. 2688297)) | |
| -40 °C ... 70 °C (Extended, see Section “Tested successfully: use under extreme ambient conditions” in the user manual) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Permissible humidity (operation) | 5 % ... 95 % (according to DIN EN 61131-2) | 
| Permissible humidity (storage/transport) | 5 % ... 95 % (according to DIN EN 61131-2) | 
| Shock (operation) | 30g (in accordance with EN 60068-2-27/IEC 60068-2-27) | 
| Vibration (operation) | 5g (in accordance with EN 60068-2-6/IEC 60068-2-6) | 
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | 
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) | 
| ATEX | |
| Identification |  II 3 G Ex ec IIC T4 Gc | 
| Certificate | UL 25 ATEX 3349X | 
| IECEx | |
| Identification | Ex ec IIC T4 Gc | 
| Certificate | IECEx ULD 25.0004X | 
| UL Ex, USA / Canada | |
| Identification | Class I, Zone 2, AEx ec IIC T4 Gc | 
| Ex ec IIC T4 Gc X | |
| Certificate | E366272 | 
| UL, USA/Canada | |
| Identification | cULus | 
| Certificate | E238705 | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Electrostatic discharge (ESD)IEC 61000-4-2 Criterion B, ±6 kV contact discharge, ±8 kV air discharge | 
| Immunity test in accordance with EN IEC 61000-6-2 Electromagnetic fieldsIEC 61000-4-3 Criterion A, Field intensity: 10 V/m | |
| Immunity test in accordance with EN IEC 61000-6-2 Fast transients (burst)IEC 61000-4-4 Criterion B, ±2 kV | |
| Immunity test in accordance with EN IEC 61000-6-2 Transient overvoltage (surge)IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1.0 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1.0 kV | |
| Immunity test in accordance with EN IEC 61000-6-2 Conducted interferenceIEC 61000-4-6 Criterion A, Test voltage 10 V | |
| Noise emission test in accordance with EN IEC 61000-6-3 Class B | 
| Mounting type | DIN rail mounting | 
| Item number | 1069208 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Sales key | DRADAD | 
| Product key | DRADAD | 
| GTIN | 4055626741192 | 
| Weight per piece (including packing) | 536.25 g | 
| Weight per piece (excluding packing) | 476.15 g | 
| Customs tariff number | 85371091 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27242207 | 
| ECLASS-15.0 | 27242207 | 
ETIM
| ETIM 9.0 | EC000236 | 
UNSPSC
| UNSPSC 21.0 | 32151700 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 6(a), 6(a)-I, 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | 
              EFUP-50
               An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. 
             | 
          
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) | 
| SCIP | af0e0fbc-0c65-4147-b7b5-a67bef6bf16c | 
Compatible products
- 
    
      
PLCNEXT ENGINEER - Programming software 1046008
 - 
    
      
SD FLASH 2GB PLCNEXT MEMORY - Program/configuration memory 1043501
 - 
    
      
SD FLASH 8GB PLCNEXT MEMORY - Program/configuration memory 1061701
 - 
    
      
SD FLASH 8GB PLCNEXT MEMORY LIC - Program/configuration memory 1151112
 - 
    
      
SD FLASH 32GB PLCNEXT MEMORY LIC - Program/configuration memory 1151111
 - 
    
      
SD FLASH PLCNEXT MEMORY LIC CFG - Program/configuration memory 1308064
 - 
    
      
AXC F IL ADAPT - PLC extension module 1020304
 - 
    
      
AXC F XT ETH 1TX - PLC extension module 2403115
 - 
    
      
AXC F XT IB - PLC extension module 2403018
 - 
    
      
AXC F XT PB - PLC extension module 1091657
 - 
    
      
AXC F XT KIT - PLC extension module 1383116
 - 
    
      
AXC F XT EXP - PLC extension module 1139999
 - 
    
      
AXC F XT ML 1000 - PLC extension module 1259849
 - 
    
      
AXC F XT SPLC 1000 - PLC extension module 1159811
 - 
    
      
AXC F XT SPLC 3000 - PLC extension module 1160157
 - 
    
      
AXL F PWR 1H - Feed-in module 2688297
 - 
    
      
CAB-USB A/ USB C/1,8M - Connecting cable 2404677
 - 
    
      
CAB-USB C/ USB C/1,8M - Connecting cable 1021809
 - 
    
      
PLCNEXT TECHNOLOGY TOOLCHAIN - Programming software 1639782
 - 
    
      
AXL BS 31 SPARE PART - Replacement part 1672303
 
Your advantages
Real-time-capable Linux operating system for deterministic and reliable execution of time-critical processes
        Supports numerous protocols such as: HTTP, HTTPS, FTP, OPC UA, SNTP, SNMP, SMTP, SQL, MySQL, DCP, etc. – for smooth communication with IT systems
        Direct connection to the Proficloud, the PLCnext Store and any cloud platforms – for seamless IoT integration of your applications
        Support for numerous fieldbus protocols (PROFINET, Modbus TCP/RTU, Ethernet/IP, etc.) for easy integration into existing automation technology systems and installations
        Maximum design freedom thanks to the combination of classic PLC programming with modern high-level languages such as C++, C#, or Python
        Meets the highest security requirements of industrial automation – for the protection of your applications and data
        PHOENIX CONTACT PTY Ltd.
        
        Level 12 1PSQ, 169 Macquarie Street, Parramatta NSW 2150