Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.
Signal conditioners and measuring transducers for standard applications
Signal conditioners and measuring transducers isolate, convert, filter, and amplify signals as an interface between field and controller. MACX Analog und MINI Analog Pro offer flexible solutions for AI, AO, DI, temperature, frequency, and limit values. MINI Analog Pro is a user-friendly and space-saving product family. MACX Analog guarantees the safety of people, the environment, and the system with functional safety.
Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.
Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, order configuration
Analog frequency transducer with limit value functionality and plug-in connection technology for converting standard signals into frequency or PWM signals. Configurable via DIP switch or software. Screw connection technology, standard configuration.
Output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, screw connection.
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, screw connection, SIL 2.
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, screw connection.
Universally configurable temperature limit value switch with two transistor outputs for the connection of 2, 3, and 4-conductor resistance thermometers and thermocouples. Configurable via DIP switch or software, screw connection technology
Universally configurable frequency transducer for converting frequency (Hz/rpm) and PWM signals into standard signals. Sensor voltages greater than 8.2 V DC are possible in combination with MINI MCR-2-SPS-PT 1033201. Push-in connection technology, order configuration.
Your advantages with our highly compact MINI Analog Pro signal conditioners
- Easy installation with easily accessible terminal points, power bridging, and plug-in connection terminal blocks; also with Push-in connection technology
- Easy startup and servicing: measure signals without disconnecting current loops, plus optional disconnect function
- Wide range of parameterization options: easy configuration via DIP switches as well as advanced configuration via software or smartphone app without additional accessories
- Service-friendly with large-surface marking areas, status LEDs in every signal conditioner, and group error indication
- The highly compact MINI Analog Pro signal conditioners with plug-in connection technology are part of the COMPLETE line system
Easy installation and startup
1. Easy installation:
Clearly visible and easily accessible terminal points and FASTCON Pro plug-in connection terminal blocks.
2. Easy startup and servicing:
Interrupt signal and supply circuits in no time at all with the integrated disconnect function.
3. Measure current signals easily:
Measure current signals during operation, without disconnecting the current loop.
4. Wide range of parameterization options:
Easy configuration via DIP switches as well as advanced configuration via software or smartphone app without additional accessories.
MINI Analog Pro signal conditioners feature easy installation and startup
Highly compact MINI Analog Pro signal conditioners: Safely isolated from the field to the network
Modular signal conditioner combination with plug-in gateways
Safely isolated from field to network
The easy-to-attach gateways allow you to integrate any MINI Analog Pro signal conditioner with current or digital output into your network in a space-saving way. Signal-specific input cards are no longer required. MINI Analog Pro gateways for bus and network connection are available for the following protocols:
- PROFINET
- Modbus/RTU
- Modbus/TCP
- PROFIBUS DP
Your advantages with the gateways for bus and network communication
- Space-saving network integration of freely combinable signal conditioners with compact plug-in gateways
- Interference-free signal transmission to the CPU with safe electrical isolation, even between the individual channels
- Cost and space savings at control level, because signal-specific input cards are no longer required
- Easy startup and servicing: measure current signals during operation or read them off on your smartphone via NFC
- Quick parameterization via rotary coding switch, software, or the MINI Analog Pro app