The CATAN DOR6 UI8 extension module is housed in a compact REG housing with an overall width of just 6 HP. It extends a Catan controller by eight additional universal inputs and six relay outputs for 230 V AC/16 A. The universal inputs are suitable for temperature sensors, 0 V ... 10 V interfaces or as meters, among other things. The bistable relays have contacts as N/C contacts and N/O contacts. They are designed for very high inrush currents.
CATAN DOR6 UI8
-
Relay module
1371364
Extension module for Catan controller. 8 universal inputs and 6 digital outputs with bistable relays for 230 V AC/16 A. Local override operation via Catan Control Panel. Connection to the Catan controller via Single Pair Ethernet.
Product details
Dimensions without display connected | |
Width | 89.7 mm |
Height | 60.7 mm |
Length | 107.6 mm |
Dimensions with display connected | |
Width | 89.7 mm |
Height | 68 mm |
Length | 107.6 mm |
Note on application | |
Note on application | Only for industrial use |
Extension bus (link bus) | |
Number of interfaces | 2 (for extension modules) |
Connection method | Push-in connection |
Note on the connection method | Single Pair Ethernet (SPE) 10BASE-T1L, shielded |
Transmission speed | 10 Mbps |
Transmission length | max. 350 m (between two devices) |
Connection for Catan Control Panel | |
Number of interfaces | 1 |
Connection method | USB 2.0 full speed, socket type C |
Transmission speed | max. 12 Mbps |
Analog: Universal input | |
Input name | Analog current inputs |
Current input signal | 0 mA ... 20 mA |
4 mA ... 20 mA | |
Protective circuit | Surge protection |
Analog: Universal input | |
Input name | Analog voltage inputs |
Voltage input signal | 0 V ... 10 V |
Input resistance of voltage input | > 5 MΩ |
Protective circuit | Surge protection |
Digital: Universal input | |
Input name | Digital inputs |
Description of the input | EN 61131-2 type 2 and 3 |
Input voltage range "0" signal | -3 V DC ... 5 V DC (An open input always provides a 0 signal.) |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Nominal input voltage UIN | 24 V DC |
Digital: Universal input | |
Input name | Floating contacts |
Input information | Connect the contact to ground. |
Description of the input | Open/closed contact |
Analog | |
Input name | Analog temperature inputs |
Sensor types (RTD) that can be used | Pt 1000 |
Analog | |
Input name | Analog temperature inputs |
Sensor types (RTD) that can be used | Ni 1000, LG-Ni 1000 |
Analog | |
Input name | Analog temperature inputs |
Sensor types that can be used (TC) | NTC 10k, NTC 20k, NTC 10 k Pre |
Analog | |
Input name | Analog resistance inputs |
Analog | |
Input name | Analog resistance inputs |
Counter: Universal input | |
Input name | Counter inputs |
Input frequency | max. 20 Hz (Signal is debounced) |
Resolution | 1 Impulse |
Relay | |
Number of outputs | 6 (Changeover contact) |
Connection method | Push-in connection |
Switching voltage | max. 250 V |
Switching capacity | max. 4000 VA |
Limiting continuous current | 16 A (Resistive load) |
Mechanical service life | 106 cycles |
Product type | I/O component |
Product family | Catan |
Mounting position | horizontal |
Alternative mounting positions are possible, but can lead to a reduction in thermal performance. | |
Installation location | indoor use |
Insulation characteristics | |
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Supply: | |
Designation | Supply |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current consumption | max. 250 mA |
100 mA (without external load) | |
150 mA (with display) | |
Electrical isolation/isolation of the voltage ranges | |
Test voltage: Extension bus/communications | 500 V AC, 50 Hz, 1 min |
Test voltage: Logic/functional ground | 500 V AC, 50 Hz, 1 min |
Test voltage: Relay contact / logic | 4 kV AC, 50 Hz, 1 min |
Test voltage: Relay contact / functional ground | 4 kV AC, 50 Hz, 1 min |
Test voltage: Relay contact/relay contact (open contact) | 1 kV, 50 Hz, 1 min |
Connection technology | |
Connection name | Connections 1 ... 19 (relay) |
Connections 1 ... 19 (relay) | |
Connection method | Push-in connection |
Conductor cross section, flexible | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Stripping length | 10 mm |
Conductor cross section, rigid | 0.2 mm² ... 4 mm² (Conductor connection with open terminal point) |
0.5 mm² ... 4 mm² (Push-in connection) | |
Nominal cross section | 4 mm² |
Connections 31 ... 62 (power supply, link bus, universal inputs) | |
Connection method | Push-in connection |
Conductor cross section, flexible | 0.5 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Stripping length | 10 mm |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² (Conductor connection with open terminal point) |
0.34 mm² ... 1.5 mm² (Push-in connection) | |
Nominal cross section | 1.5 mm² |
Ambient conditions | |
Ambient temperature (operation) | -5 °C ... 50 °C (up to 3000 m above mean sea level) |
Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Mounting type | DIN rail mounting (in accordance with DIN EN 60715) |
Mounting position | horizontal |
Item number | 1371364 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | O1 - Automatation Systems |
Product key | DRHABA |
GTIN | 4063151729950 |
Weight per piece (including packing) | 292 g |
Weight per piece (excluding packing) | 270 g |
Customs tariff number | 85371098 |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 27242604 |
ETIM
ETIM 9.0 | EC001599 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead titanium zirconium oxide (CAS: 12626-81-2) |
Lead (CAS: 7439-92-1) |
Compatible products
Your advantages
Space and cost savings thanks to highly flexible I/O configurability
High-performance extension bus also enables distributed installation
Startup and maintenance with plug-in display for local operation
Power-saving bistable relays for high inrush currents
Digital twin as the basis for smart buildings
Phoenix Contact GmbH & Co. KG
Flachsmarktstraße 8, D-32825 Blomberg