MACX MCR-SL-IDSI-I
   - 
  Output signal conditioner
    
      2865971
      
      
    
  
      Output signal conditioner, HART. Isolates and transmits 0/4 - 20 mA signals to a load (I/P converters, regulating valves, displays). Open-circuit detection, SIL 2 in accordance with IEC 61508, screw connection. Replacement item: 2908063 MACX MCR-IDS-I-I.
Product details
| Product type | Output signal conditioner | 
| Application | Analog OUT | 
| No. of channels | 1 | 
| Insulation characteristics | |
| Overvoltage category | II | 
| Pollution degree | 2 | 
| Electrical isolation between input and output | yes | 
| Signal transmission behavior | In = Out | 
| Step response (10-90%) | < 140 µs (for 4 mA ... 20 mA step) | 
| Maximum temperature coefficient | < 0.01 %/K | 
| Maximum transmission error | < 0.1 % (of final value) | 
| Transmission error, typical | < 0.05 % (of final value) | 
| Electrical isolation Input/output/power supply | |
| Rated insulation voltage | 300 Vrms | 
| Test voltage | 1.5 kV AC (50 Hz, 60 s) | 
| Supply | |
| Nominal supply voltage | 24 V DC | 
| Supply voltage range | 19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %) | 
| Max. current consumption | < 46 mA (24 V DC / 20 mA) | 
| Power dissipation | < 1.1 W (24 V DC / 20 mA) | 
| Signal: Current | |
| Number of inputs | 1 | 
| Current input signal | 0 mA ... 20 mA | 
| 4 mA ... 20 mA | |
| Input impedance | > 100 kΩ (If there is a line fault) | 
| Voltage drop | 5.4 V (20 mA) | 
| Signal: Current | |
| Output description | Current output | 
| Number of outputs | 1 | 
| Current output signal | 0 mA ... 20 mA | 
| 4 mA ... 20 mA | |
| Load/output load current output | < 800 Ω (20 mA) | 
| < 730 Ω (22.5 mA) | |
| Output ripple | < 20 mVrms | 
| Connection method | Screw connection | 
| Stripping length | 7 mm | 
| Screw thread | M3 | 
| Conductor cross-section rigid | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section flexible | 0.2 mm² ... 2.5 mm² | 
| Conductor cross-section AWG | 24 ... 14 | 
| Tightening torque | 0.5 Nm ... 0.6 Nm | 
| Data communication (bypass) | |
| HART function | Yes | 
| Protocols supported | HART | 
| Status display | Green LED (supply voltage) | 
| Dimensional drawing |  | 
| Width | 12.5 mm | 
| Height | 112.5 mm | 
| Depth | 114.5 mm | 
| Color | gray (RAL 7042) | 
| Flammability rating according to UL 94 (Housing) | V0 (Housing) | 
| Housing material | PA 6.6-FR | 
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 2 | 
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 2 | 
| Ambient conditions | |
| Degree of protection | IP20 (not assessed by UL) | 
| Ambient temperature (operation) | -20 °C ... 60 °C (Any mounting position) | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Altitude | ≤ 2000 m | 
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) | 
| CE | |
| Certificate | CE-compliant | 
| Note | and EN 61326-1 | 
| ATEX | |
| Identification |  II 3 G Ex nA IIC T4 Gc X | 
| UL, USA/Canada | |
| Identification | UL 508 Listed | 
| UL 61010 Listed | |
| Class I, Div. 2, Groups A, B, C, D T4 | |
| Class I, Zone 2, Group IIC T4 | |
| Shipbuilding approval | |
| Identification | C, EMC1 | 
| Certificate | DNV GL TAA00000AG | 
| Safety Integrity Level (SIL, IEC 61508) | |
| Identification | 2 | 
| Shipbuilding data | |
| Temperature | B | 
| Humidity | B | 
| Vibration | A | 
| EMC | B | 
| Enclosure | Required protection according to the Rules shall be provided upon installation on board | 
| Electromagnetic compatibility | Conformance with EMC directive | 
| Noise immunity | EN 61000-6-2 | 
| Noise emission | |
| Standards/regulations | EN 61000-6-4 | 
| Electromagnetic HF field | |
| Designation | Electromagnetic RF field | 
| Standards/regulations | EN 61000-4-3 | 
| Mounting type | DIN rail mounting | 
| Item number | 2865971 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Sales key | J1 - MSR Technology | 
| Product key | DK1112 | 
| GTIN | 4046356449540 | 
| Weight per piece (including packing) | 175,2 g | 
| Weight per piece (excluding packing) | 140,9 g | 
| Customs tariff number | 85437090 | 
| Country of origin | DE | 
UNSPSC
| UNSPSC 21.0 | 39121008 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 7(a), 7(c)-I | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | No substance above 0.1 wt% | 
Compatible products
- 
    
      
- 
    
      MACX MCR-PTB - Power and error message module 2865625
- 
    
      MACX MCR-PTB-SP - Power and error message module 2924184
- 
    
      TC-D37SUB-ADIO16-EX-P-UNI - Module carrier 2924854
- 
    
      TC-D37SUB-AIO16-EX-PS-UNI - Module carrier 2902932
- 
    
      GW HART USB MODEM - Cable adapter 1003824
- 
    
      UC-EMLP (11X9) - Plastic label 0819291
- 
    
      UC-EMLP (11X9) CUS - Plastic label 0824547
- 
    
      UC-EMLP (11X9) YE - Plastic label 0822602
- 
    
      UC-EMLP (11X9) YE CUS - Plastic label 0824548
- 
    
      UC-EMLP (11X9) SR - Plastic label 0828094
- 
    
      UC-EMLP (11X9) SR CUS - Plastic label 0828098
- 
    
      US-EMLP (11X9) - Plastic label 0828789
- 
    
      US-EMLP (11X9) YE - Plastic label 0828871
- 
    
      US-EMLP (11X9) SR - Plastic label 0828872
- 
    
      LS-EMLP (11X9) WH - Device marker 0831678
- 
    
      LS-EMLP (11X9) YE - Device marker 0831732
- 
    
      LS-EMLP (11X9) SR - Device marker 0831705
- 
    
      MPS-MT - Test plug 0201744
- 
    
      MPS-IH BK - Insulating sleeve 0201731
- 
    
      MPS-IH GY - Insulating sleeve 0201728
- 
    
      MPS-IH GN - Insulating sleeve 0201702
- 
    
      MPS-IH YE - Insulating sleeve 0201692
- 
    
      MPS-IH BU - Insulating sleeve 0201689
- 
    
      MPS-IH RD - Insulating sleeve 0201676
- 
    
      MPS-IH WH - Insulating sleeve 0201663
Your advantages
Power supply possible via DIN rail connector
        Up to SIL 2 in accordance with EN 61508
        Installation in zone 2, protection type "n" (EN 60079-15) permitted
        Line fault detection (LFD)
        3-way electrical isolation
        Plug-in screw or spring-cage connection technology (Push-in technology), with integrated sockets for HART communicators
        Bidirectional transmission of digital HART communication signals
        Input: 0/4 mA ... 20 mA
        Output: 0/4 mA ... 20 mA
        Phoenix Contact GmbH & Co. KG
        
        Flachsmarktstraße 8, D-32825 Blomberg