You can connect this Axioline E device to an IO-Link master via an IO-Link A port. You can use this device to capture digital signals via IO-Link. Use within different networks is possible via the IO-Link master.
AXL E IOL DI8 M12 3M
-
Digital module
1480996
Axioline E, Digital input device, IO-Link ports Class A: 1, connection method: M12 connector, A-coded, connection technology: 3-conductor, Digital inputs: 8, 24 V DC, connection technology: 4-conductor, IO-Link, degree of protection: IP65/IP67/IP69
Free download available.
Downloads
Product details
Dimensional drawing |
|
Width | 30 mm |
Height | 184 mm |
Depth | 30.3 mm |
Note on application | |
Note on application | Only for industrial use |
Housing material | Die-cast zinc |
Digital: | |
Input name | Digital inputs |
Description of the input | EN 61131-2 types 1 and 3 |
Number of inputs | 8 |
Cable length | max. 30 m (to the sensor) |
Connection method | M12 connector, A-coded |
Note on the connection method | Push-pull fast connection according to IEC 61076-2-010 or screw connection according to IEC 61076-2-101 |
Connection technology | 4-conductor |
Input voltage range "0" signal | -3 V ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Nominal input voltage UIN | 24 V DC |
Nominal input current at UIN | typ. 2.5 mA |
Input filter time | 1 ms |
Protective circuit | Reverse polarity protection; yes |
Short-circuit protection; yes | |
Overload protection; yes | |
IO-Link | |
Number of ports | 1 |
Connection method | M12 connector, A-coded |
Note on the connection method | Push-pull fast connection according to IEC 61076-2-010 or screw connection according to IEC 61076-2-101 |
Connection technology | 3-conductor |
Port type | Class A |
Specification | V1.1.3 |
Reverse polarity protection | yes |
Transmission speed | 230.4 kbps (COM3) |
Cycle Time | 1 ms |
Amount of process data | 2 Byte (Input data) |
0 Byte (Output data) |
Product type | I/O component |
Product family | Axioline E |
Type | Stand-Alone |
Special properties | IO-Link |
Insulation characteristics | |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Supply: IO-Link | |
Designation | IO-Link port supply (L+) |
Nominal voltage for I/O supply | 24 V DC (Provided via the IO-Link interface of the IO-Link master.) |
Supply voltage range | 18 V DC ... 30 V DC (including all tolerances, including ripple) |
Nominal current per device | typ. 30 mA |
Current consumption | max. 800 mA (Device dependent; observe the current of the IO-Link master that is made available via L+.) |
Protective circuit | Reverse polarity protection; yes |
Supply: Sensors | |
Designation | Supply of the sensors (from L+) |
Current consumption | max. 800 mA (per port) |
max. 800 mA (Device dependent; observe the current of the IO-Link master that is made available via L+.) | |
Electrical isolation/isolation of the voltage ranges | |
Test voltage: 24 V supply L+ (IO-Link)/functional ground | 500 V AC, 50 Hz, 1 min |
Connection method | M12 connector |
Tightening torque | 0.4 Nm |
Ambient conditions | |
Ambient temperature (operation) | -25 °C ... 70 °C |
Degree of protection | IP65/IP67/IP69 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % |
Permissible humidity (storage/transport) | 5 % ... 95 % |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Item number | 1480996 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DRI7MF |
Product key | DRI7MF |
GTIN | 4063151900403 |
Weight per piece (including packing) | 293.7 g |
Weight per piece (excluding packing) | 279 g |
Customs tariff number | 85176200 |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 27242604 |
ETIM
ETIM 9.0 | EC001599 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
Compatible products
-
-
US-EMLP-HA (20X9) - Plastic label 0830989
-
US-EML (20X8) - Label 0800458
-
PROT-M12 - Screw plug 1680539
-
PROT-M12 SH - Screw plug 1503302
-
SAC-3P-Y/2XM 8FS SCO - Y distributor 1523984
-
SAC-3P-Y/2XFS PE SCO - Y distributor 1523971
-
SAC-3P-Y/2XFS B PE SCO - Y distributor 1523968
-
SAC-5P-P12MS/ 1,5-PUR/P12FR - Sensor/actuator cable 1224223
-
SAC-5P-P12MS/ 1,5-PUR/P12FS - Sensor/actuator cable 1224208
-
SAC-5P-P12MR/ 1,5-PUR/P12FS - Sensor/actuator cable 1224229
-
SAC-5P-P12MS/ 1,5-PUR - Sensor/actuator cable 1393925
-
SAC-5P-P12MR/ 1,5-PUR - Sensor/actuator cable 1395742
-
SAC-5P-M12MS/1,5-PUR/M12FS - Sensor/actuator cable 1681606
-
SAC-5P-M12MS/1,5-PUR - Sensor/actuator cable 1669767
-
SAC-5P-M12MS/1,5-PUR/M12FR - Sensor/actuator cable 1681648
-
SAC-5P-M12MR/1,5-PUR - Sensor/actuator cable 1669796
-
SACC-P12MS-4PL-CM M - Connector 1438146
-
SACC-P12MS-5PL-CM M - Connector 1438156
-
SACC-P12MR-4PL-CM M - Connector 1438148
-
SACC-P12MR-5PL-CM M - Connector 1438158
-
SACC-M12MS-5PL M - Connector 1424649
-
SACC-M12MS-4PL M - Connector 1424657
-
SACC-P12FS-4PL-CM M - Connector 1438151
-
SACC-P12FR-4PL-CM M - Connector 1438155
-
SACC-P12FR-5PL-CM M - Connector 1438162
-
SACC-P12FS-5PL-CM M - Connector 1438159
-
SACC-M12FS-5PL M - Connector 1424652
-
SACC-M12FS-4PL M - Connector 1424655
-
SAC BIT M12-D15 - Tool 1208432
-
SACC BIT M12-D20 - Tool 1208445
-
TSD 04 SAC - Torque screwdriver 1208429
-
NF PD IOL R - Inductive coupler 1736165
-
NF PD IOL B - Inductive coupler 1736167
Your advantages
Connection to an IO-Link master with M12 connector (A-coded, 4-pos.)
Type A port
IO-Link specification V1.1.3
Connection of up to 8 inputs with M12 connectors (A-coded, 5-pos.)
Diagnostic and status indicators
Single-channel diagnostics
Short-circuit and overload protection of the sensor supply
Device rating plate stored
IP65/IP67/IP69 degree of protection
PHOENIX CONTACT AS
Strømsveien 344; N-1081 Oslo