With the robust NEARFI-PD… NearFi couplers, you can transmit power (24 V DC / 2 A) and real-time Ethernet data (100 Mbps, full duplex) without contact across a distance in the centimeter range. Furthermore, the specially developed NearFi technology enables latency-free and protocol-independent Ethernet communication. At the same time, the limited wireless range of just a few centimeters also ensures security and permits parallel applications in the tightest of spaces. You can therefore replace wear-sensitive and maintenance-intensive connections and reduce downtimes in your systems.
NEARFI PD 2A ETH B
-
Inductive coupler
1234224
NearFi base, contactless power and real-time Ethernet coupler, 50 W (US), 100 Mbps, range ≤10 mm, M12 screw connection, IP65, can be combined with NEARFI PD 2A ETH R. Incompatible with NEARFI 2200 (new)
Product details
Product type | Inductive coupler |
Product family | NearFi |
Application | Ethernet |
Power | |
MTTF | 115 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
60 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
27 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) | |
Insulation characteristics | |
Overvoltage category | II |
Pollution degree | 2 |
Maximum power dissipation for nominal condition | 4.08 W |
Supply | |
Supply voltage range | 19 V DC ... 30 V DC |
Typical current consumption | 170 mA (without remote coupler, at 24 V DC, at 25°C) |
480 mA (with remote coupler, without load, at 24 V DC, at 25°C) | |
Max. current consumption | ≤ 3.6 A (with remote coupler, 2 A load, input voltage of 19 V DC) |
Inrush current | ≤ 0.8 A (8 ms at 24 V DC, without remote coupler) |
≤ 4.5 A (6 ms at 24 V DC, with remote coupler, without load) | |
Protective circuit | Transient protection, polarity protection |
Digital | |
Description of the input | Digital input |
Number of inputs | 1 |
Voltage input signal | 19 V DC ... 30 V DC |
Switching level "1" signal | 19 V DC ... 30 V DC |
Signal | |
Output name | Digital output |
Number of outputs | 1 |
Voltage output signal | ≤ 24 V DC |
Supply | |
Connection method | M12 male, A-coded |
Data: Ethernet interface, 100Base-T(X) in accordance with IEEE 802.3 | |
Transmission speed | 100 Mbps |
Connection method | M12 female, D-coded |
Note on the connection method | Auto negotiation and autocrossing, fast startup (FSU, <500 ms) |
Typical bit error rate ≤10-12 | |
No. of channels | 1 |
Transmission length | 100 m (shielded twisted pair) |
Transmission medium | Copper |
Protocols supported | Protocol transparent: PROFINET, PROFINET IRT, PROFIsafe, EtherCAT®, Modbus/TCP, Powerlink, TSN, etc. |
Inductive: Power transmission | |
Switch-on time | < 450 ms (ETH Full Duplex operating mode) |
Range | min. 0 mm |
≤ 10 mm (at 55°C) | |
≤ 12 mm (at 25 °C) | |
Center offset | ± 5 mm |
Wireless modules that can be connected | 1 (Remote coupler) |
Frequency range | 100 kHz ... 148.5 kHz (Power transmission) |
Test field strength | ~ 1.95 µA/m (within 10 m distance) |
Wireless | |
Wireless modules that can be connected | 1 (Remote coupler) |
Frequency | 60 GHz |
Frequency range | 57 GHz ... 64 GHz (Data transmission) |
Transmission power | < 10 mW (EIRP) |
Delay time | ≤ 1 µs (typical) |
Dimensional drawing |
|
Width | 80 mm |
Height | 86 mm |
Depth | 39 mm |
Color (Housing) | black (RAL 9005) |
Material (Enclosure) | PBT |
Die-cast zinc | |
Flammability rating according to UL 94 | V0 |
Other resistance | Resistant to welding splashes |
Resistant to salt spray in accordance with IEC 60068-2-11 (96 h in 5% salt spray) |
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6 | : 5 g per spatial direction, 10 Hz ... 150 Hz, amplitude ±0.34 mm |
Shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 30 g, 11 ms duration, half-sine shock pulse, three shocks per spatial direction |
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 10 g, 16 ms duration, half-sine shock pulse, 1,000 shocks per spatial direction |
Ambient conditions | |
Degree of protection | IP65 (Manufacturer's declaration) |
Impact strength | IK06 |
Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | 2000 m |
Permissible humidity (operation) | 10 % ... 95 % |
Permissible humidity (storage/transport) | 10 % ... 95 % |
Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
CE | |
Certificate | CE-compliant |
Wireless approval, Europe | |
Note | RED 2014/53/EU |
UL, USA | |
Identification | UL 61010 Recognized |
UL 61010-2-201, 2nd Edition | |
UL 61010-1, 3rd Edition | |
Certificate | E238705 |
UL, Canada | |
Identification | cUL 61010 Recognized |
CSA C22.2 NO. 61010-2-201:18, 2nd Edition | |
CSA C22.2 NO. 61010-1, 3rd Edition | |
Certificate | E238705 |
Wireless approval USA, FCC | |
Certificate | YG3PD2AETHB |
Wireless approval Japan, MIC | |
Identification | 006-001058 |
KC approval for South Korea | |
Certificate | R-R-PCK-1234232 |
CC-Link IE TSN | |
Identification | Class A |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Contact discharge | ± 4 kV (Test Level 2) |
Discharge in air | ± 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 80 MHz ... 1 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | ± 2 kV (Test Level 3 - asymmetrical) |
Output | ± 2 kV (Test Level 3 - asymmetrical) |
Signal | ± 2 kV (Test Level 3 - asymmetrical) |
Comments | Criterion B |
Surge current load (surge) | |
Standards/regulations | EN 61000-4-5 |
Surge current load (surge) | |
Input | ± 0.5 kV (Test Level 1 - symmetrical) |
± 1 kV (Test Level 2 - asymmetrical) | |
Output | ± 1 kV (Test Level 2 - asymmetrical) |
Signal | ± 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
Frequency range | 0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical) |
Comments | Criterion A |
Voltage | 10 V (80% amplitude modulation with 1 kHz) |
Emitted interference | |
Standards/regulations | EN 55016-2-3 |
Comments | Class A, industrial applications |
Criteria | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Free from substances that could impair the application of coating | VDMA 24364:2018-05 |
Other resistance | Resistant to welding splashes |
Resistant to salt spray in accordance with IEC 60068-2-11 (96 h in 5% salt spray) | |
Standards/regulations | EN 60204-1 (PELV) |
Standard designation | Protective extra-low voltage |
Mounting type | Panel mounting |
Assembly note | Observe derating |
Mounting position | any |
Item number | 1234224 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DNC |
Product key | DNC691 |
GTIN | 4063151337919 |
Weight per piece (including packing) | 598.2 g |
Weight per piece (excluding packing) | 550 g |
Customs tariff number | 85176200 |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 27040701 |
ECLASS-15.0 | 19170417 |
ETIM
ETIM 9.0 | EC002540 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 6(c) |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
SCIP | d92acee4-1886-4061-b33b-27dc6f8a5818 |
Compatible products
-
SAC-5P- 2,0-186/FS SCO - Sensor/actuator cable 1518368
-
SAC-5P- 5,0-186/FS SCO - Sensor/actuator cable 1518371
-
SAC-5P-10,0-186/FS SCO - Sensor/actuator cable 1518384
-
SAC-5P-15,0-186/FS SCO - Sensor/actuator cable 1518397
-
SAC-5P-MS/ 1,0-186/FS SCO - Sensor/actuator cable 1518423
-
SAC-5P-MS/ 2,0-186/FS SCO - Sensor/actuator cable 1518436
-
SAC-5P-MS/ 5,0-186/FS SCO - Sensor/actuator cable 1518449
-
SAC-5P-MS/10,0-186/FS SCO - Sensor/actuator cable 1518452
-
SAC-5P-MS/15,0-186/FS SCO - Sensor/actuator cable 1518465
-
SACC-M12MS-5CON-PG 9-M - Connector 1681460
-
SACC-M12FS-5CON-PG9-M - Connector 1681486
-
SACC-M12MR-5CON-PG9-M - Connector 1681473
-
SACC-M12FR-5CON-PG9-M - Connector 1681499
-
NBC-M12MSD/.../... - Network cable 1408713
-
NBC-M12MSD-M12MSD/.../... - Network cable 1408706
-
NBC-M12MSD-R4AC/.../... - Network cable 1408712
-
NBC-M12MSD/ 1,0-93B - Network cable 1407495
-
NBC-M12MSD/ 2,0-93B - Network cable 1407496
-
NBC-M12MSD/ 5,0-93B - Network cable 1407497
-
NBC-M12MSD/10,0-93B - Network cable 1407498
-
NBC-M12MSD/ 1,0-93B/R4AC - Network cable 1407499
-
NBC-M12MSD/ 2,0-93B/R4AC - Network cable 1407500
-
NBC-M12MSD/ 5,0-93B/R4AC - Network cable 1407501
-
NBC-M12MSD/10,0-93B/R4AC - Network cable 1407502
-
NBC-M12MSD/ 1,0-93B/M12MSD - Network cable 1407524
-
NBC-M12MSD/ 2,0-93B/M12MSD - Network cable 1407525
-
NBC-M12MSD/ 5,0-93B/M12MSD - Network cable 1407526
-
NBC-M12MSD/10,0-93B/M12MSD - Network cable 1407527
-
SACC-M12MRD-4Q SH - Data connector 1553624
-
SACC-M12MSD-4QO SH ETH - Data connector 1411066
-
SACC-M12MSD-4QO SH PN - Data connector 1411068
-
SACC-M12MRD-4Q SH PN - Data connector 1554539
-
SACC-M12MRD-4PL SH PN - Connector 1424684
-
VS-08-RJ45-5-Q/IP20 - RJ45 connector 1656725
-
PROT-M12 - Screw plug 1680539
Your advantages
Frequently asked questions
When do I use the A-coded device variants (NEARFI PD, NEARFI P, NEARFI D)?
The A-coded device variants can be used as replacements in existing systems and applications. The A-coded devices are incompatible with the L-coded devices (NEARFI 2xxx).
When do I use the L-coded device variants (NEARFI 2000, NEARFI 200/300, NEARFI 2200)?
The L-coded device variants can be used for new projects. The L-coded devices enable doubling of the range during data transmission, power duplication through parallel connection, and other functions. The L-coded devices are incompatible with the A-coded devices.
Do the devices meet the cybersecurity requirements of the Radio Equipment Directive (RED)?
The requirements of Delegated Act 2022/30 of the RED 2014/53/EU with regard to article 3.3 d,e,f do not apply to the product.
Article 3.3, d: The devices do not have active access to network communication They are not able to disrupt network commu...
View more
The requirements of Delegated Act 2022/30 of the RED 2014/53/EU with regard to article 3.3 d,e,f do not apply to the product.
Article 3.3, d: The devices do not have active access to network communication They are not able to disrupt network communication or misuse resources. Therefore, this requirement does not apply to the devices.
Article 3.3, e: Not applicable to the devices, as no personal data is processed and the privacy of end users is not affected
Article 3.3, f: Not applicable, as the devices are not used for financial transactions