High-availability PLCnext controller for PROFINET networks with S2 system redundancy functionality.
When it comes to high-availability, distributed, and modular automation, PLCnext controllers with IEC 61131 control intelligence, redundancy technology, and network connection are the ideal solution. Thanks to the integrated FO-based redundancy function, you can reduce system downtimes, work cost effectively, and also avoid potential hazards. Virtual IP technology enables easy and user-friendly connection of SCADA systems. The integrated OPC UA server/client function allows for a cascaded topology of redundancy levels.
Please note that this controller type does not currently support the “Download Changes” function.
RFC 4072R
-
Controller
1136419
Free download available.
Downloads
Product details
| Note on application | |
| Note on application | Only for industrial use |
| Product type | Controller |
| Product family | PLCnext Control |
| Type | Stand-alone |
| Special properties | System redundancy |
| Insulation characteristics | |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Pollution degree | 2 (when installed in a control cabinet or housing with IP54 degree of protection or higher) |
| Display | |
| Diagnostics display | yes |
| Flash memory | 100 Mbyte (internal flash memory) |
| SD card from Phoenix Contact (for external flash memory, see accessories) | |
| Retentive data storage | 2 Mbyte |
| IEC 61131 runtime system | |
| Program memory | 16 Mbyte |
| Data storage system | 32 Mbyte |
| PROFINET | |
| Device function | PROFINET-Controller |
| Number of supported devices | max. 256 |
| Vendor ID | 00B0hex / 176dez |
| Function | |
| Diagnostics display | yes |
| Redundancy function | yes |
| Note on redundancy function | Controller redundancy |
| Safety function | no |
| Functionality | |
| Programming languages supported | Instruction list (IL) |
| Symbolic flowchart (SFC) | |
| Ladder diagram (LD) | |
| Function block diagram (FBD) | |
| Structured text (ST) | |
| C++ | |
| C# | |
| Java | |
| Python® | |
| Simulink® | |
| System requirements | |
| Engineering tool | PLCnext Engineer |
| Eclipse® | |
| Visual Studio® | |
| MATLAB®/ Simulink® | |
| Application interface | OPC UA® |
| OPC UA Pub/Sub | |
| Power consumption | typ. 25 W (Without fan module) |
| max. 35 W (With fan module) | |
| Maximum power dissipation for nominal condition | 25 W (Without fan module) |
| Transmission medium | Copper |
| FO | |
| Supply | |
| Supply voltage | 24 V DC |
| Supply voltage range | 18 V DC ... 32.1 V DC (including ripple (3.6 VPP)) |
| Power supply connection | Via COMBICON, max. conductor cross-section 2.5 mm² |
| Real-time clock | |
| Realtime clock | integrated (capacitive buffering) |
| Description realtime clock | 1.73 s/day = 20 ppm at 25 °C |
| Potentials | |
| Protective circuit | Surge protection of the supply voltage; electronic |
| Polarity reversal protection of the supply voltage; electronic | |
| Tightening torque | 0.5 ... 0.6 Nm |
| COMBICON connector | |
| Conductor cross-section, rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section, flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Web server | yes |
| USB | |
| Number of interfaces | 1 |
| Connection method | USB type A, socket |
| Ethernet | |
| Bus system | RJ45 |
| Number of interfaces | 4 |
| Connection method | RJ45 jack |
| Note on the connection method | Auto negotiation and auto crossing, auto polarity exchange |
| Transmission speed | 10/100/1000 Mbps (LAN 1/LAN 2, half duplex or full duplex) |
| 10/100 Mbps (LAN3.1/LAN3.2 (internally switched), half duplex or full duplex) | |
| External dimensions | |
| Width / Height / Depth | 122 mm / 182 mm / 173 mm (without fan module) |
| 122 mm / 220 mm / 173 mm (With fan module) | |
| Color | gray (RAL 7042) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | 0 °C ... 60 °C up to 2000 m above mean sea level (recommended: above 50°C with fan module) |
| 0 °C ... 55 °C 2000 m ... 3000 m above mean sea level (With fan module only) | |
| 0 °C ... 50 °C 3000 m ... 4000 m above mean sea level (With fan module only) | |
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Shock (operation) | 20g (in accordance with EN 60068-2-27/IEC 60068-2-27) |
| Vibration (operation) | 1g (in accordance with EN 60068-2-6/IEC 60068-2-6) |
| Air pressure (operation) | 60 kPa ... 108 kPa (up to 4000 m above mean sea level) |
| Air pressure (storage/transport) | 58 kPa ... 108 kPa (up to 4500 m above mean sea level) |
| Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37 | Use of the device in these ambient conditions is prohibited. |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conformance with EMC directives | Immunity test in accordance with EN IEC 61000-6-2 Electrostatic discharge (ESD)IEC 61000-4-2 Criterion B, ±6 kV contact discharge, ±8 kV air discharge |
| Immunity test in accordance with EN IEC 61000-6-2 Electromagnetic fieldsIEC 61000-4-3 Criterion A, Field intensity: 10 V/m | |
| Immunity test in accordance with EN IEC 61000-6-2 Fast transients (burst)IEC 61000-4-4 Criterion B, Supply lines: ±2 kV, Signal/data lines: ±2 kV | |
| Immunity test in accordance with EN IEC 61000-6-2 Transient overvoltage (surge)IEC 61000-4-5 Criterion B, supply lines: ±0.5 kV, signal/data cables: ±1 kV | |
| Immunity test in accordance with EN IEC 61000-6-2 Conducted interferenceIEC 61000-4-6 Criterion A, Test voltage 10 V | |
| Noise emission test in accordance with EN IEC 61000-6-4 Class A |
| Mounting type | DIN rail mounting |
| Item number | 1136419 |
| Packing unit | 1 pc |
| Minimum order quantity | 1 pc |
| Sales key | DRA |
| Product key | DRADBA |
| GTIN | 4063151072230 |
| Weight per piece (including packing) | 3,062 g |
| Weight per piece (excluding packing) | 2,000 g |
| Customs tariff number | 85371091 |
| Country of origin | DE |
ECLASS
| ECLASS-13.0 | 27242207 |
| ECLASS-15.0 | 27242207 |
ETIM
| ETIM 9.0 | EC000236 |
UNSPSC
| UNSPSC 21.0 | 32151700 |
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes |
| Exemption | 7(a), 7(c)-I |
| China RoHS | |
| Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| SCIP | fb620ac8-c3b8-42b6-9454-fafe7da884fb |
Compatible products
-
SD FLASH 2GB PLCNEXT MEMORY - Program/configuration memory 1043501
-
SD FLASH 8GB PLCNEXT MEMORY - Program/configuration memory 1061701
-
SD FLASH 8GB PLCNEXT MEMORY LIC - Program/configuration memory 1151112
-
SD FLASH 32GB PLCNEXT MEMORY LIC - Program/configuration memory 1151111
-
SD FLASH PLCNEXT MEMORY LIC CFG - Program/configuration memory 1308064
-
PLCNEXT ENGINEER - Programming software 1046008
-
RFC FAN MODULE - Fan 2404085
-
FL SFP SX - Media module 2891754
-
FL SFP LX - Media module 2891767
-
FL SFP LH - Media module 2989912
-
FOC-LC:PA-LC:PA-OM2:D01/1 - FO patch cable 1115633
-
FOC-LC:PA-LC:PA-OM2:D01/2 - FO patch cable 1115634
-
FOC-LC:PA-LC:PA-OM2:D01/5 - FO patch cable 1115637
-
FOC-LC:PA-LC:PA-OS2:D01/1 - FO patch cable 1115636
-
FOC-LC:PA-LC:PA-OS2:D01/2 - FO patch cable 1115629
-
FOC-LC:PA-LC:PA-OS2:D01/5 - FO patch cable 1115626
-
PLCNEXT TECHNOLOGY TOOLCHAIN - Programming software 1639782
Your advantages
Real-time-capable Linux operating system for deterministic and reliable execution of time-critical processes
Supports numerous protocols such as: HTTP, HTTPS, FTP, OPC UA, SNTP, SNMP, SMTP, SQL, MySQL, DCP, etc. – for smooth communication with IT systems
Direct connection to the Proficloud, the PLCnext Store and any cloud platforms – for seamless IoT integration of your applications
Support for numerous fieldbus protocols (PROFINET, Modbus TCP/RTU, Ethernet/IP, etc.) for easy integration into existing automation technology systems and installations
Maximum design freedom thanks to the combination of classic PLC programming with modern high-level languages such as C++, C#, or Python
Meets the highest security requirements of industrial automation – for the protection of your applications and data
Phoenix Contact UAB
Svitrigailos str. 11M, 03228 Vilnius