FLT-CP-PLUS-3C-350
   - 
  Type 1+2 combined lightning current and surge arrester
    
      2882653
      
      
    
  
      Pluggable lighting current arrester, in acc. with type 1/class I/B for 3-phase power supply networks with combined PE and N (L1, L2, L3, PEN) installed in one cable.
Product details
| Product type | Combination type | 
| IEC test classification | I / II | 
| T1 / T2 | |
| EN type | T1 / T2 | 
| IEC power supply system | TN-C | 
| Type | DIN rail module, two-section, divisible | 
| Number of positions | 3 | 
| Surge protection fault message | Optical, remote indicator contact | 
| Insulation characteristics | |
| Overvoltage category | III | 
| Pollution degree | 2 | 
| Nominal frequency fN | 50 Hz (60 Hz) | 
| Indicator/remote signaling | |
| Connection name | Remote fault indicator contact | 
| Switching function | Changeover contact | 
| Operating voltage | 12 V AC ... 250 V AC | 
| 125 V DC (200 mA DC) | |
| Operating current | 10 mA AC ... 1 A AC | 
| 1 A DC (30 V DC) | |
| Connection method | Screw terminal blocks | 
| Screw thread | M5 | 
| Tightening torque | 4.5 Nm | 
| Stripping length | 18 mm | 
| Conductor cross-section flexible | 2.5 mm² ... 25 mm² | 
| Conductor cross-section rigid | 2.5 mm² ... 35 mm² | 
| Conductor cross-section AWG | 13 ... 2 | 
| Remote fault indicator contact | |
| Connection method | Plug-in/screw connection via COMBICON | 
| Screw thread | M2 | 
| Tightening torque | 0.25 Nm | 
| Stripping length | 7 mm | 
| Conductor cross-section flexible | 0.14 mm² ... 1.5 mm² | 
| Conductor cross-section rigid | 0.14 mm² ... 1.5 mm² | 
| Conductor cross-section AWG | 28 ... 16 | 
| Dimensional drawing |  | 
| Width | 106.8 mm | 
| Height | 95 mm | 
| Depth | 71.5 mm | 
| Horizontal pitch | 6 Div. | 
| Flammability rating according to UL 94 | V-0 | 
| CTI value of material | 600 | 
| Insulating material | PA 6.6/PBT | 
| Material group | I | 
| Housing material | PBT | 
| Mechanical data | |
| Open side panel | No | 
| Mode of protection | L-PEN | 
| Direction of action | 3L-N/PE | 
| Nominal voltage UN | 240/415 V AC (TN-C) | 
| Nominal frequency fN | 50 Hz (60 Hz) | 
| Maximum continuous operating voltage UC | 350 V AC | 
| Rated load current IL | 125 A (< 55 °C) | 
| Nominal discharge current In (8/20) µs | 25 kA | 
| Maximum discharge current Imax (8/20) µs | 50 kA | 
| Impulse discharge current (10/350) µs, charge | 12.5 As | 
| Impulse discharge current (10/350) µs, specific energy | 160 kJ/Ω | 
| Impulse discharge current (10/350) µs, peak value limp | 25 kA | 
| Total discharge current ITotal (10/350) µs | 75 kA | 
| Follow current interrupt rating Ifi | 50 kA | 
| Short-circuit current rating ISCCR | 50 kA | 
| Voltage protection level Up | ≤ 1.5 kV | 
| Residual voltage Ures | ≤ 1.5 kV (at In) | 
| Front-of-wave sparkover voltage at 6 kV (1.2/50) µs | ≤ 1.5 kV | 
| TOV behavior at UT | 415 V AC (5 s / withstand mode) | 
| 457 V AC (120 min / withstand mode) | |
| Response time tA | ≤ 100 ns | 
| Max. backup fuse with V-type through wiring | 125 A (gG) | 
| Max. backup fuse with branch wiring | 315 A (gG) | 
| Ambient conditions | |
| Degree of protection | IP20 (only when all terminal points are used) | 
| Ambient temperature (operation) | -40 °C ... 80 °C | 
| Ambient temperature (storage/transport) | -40 °C ... 80 °C | 
| Altitude | ≤ 2000 m (amsl) | 
| Permissible humidity (operation) | 5 % ... 95 % | 
| Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) | 
| Vibration (operation) | 5g (5 - 500 Hz/2.5 h/X, Y, Z) | 
| UL specifications | |
| Maximum continuous operating voltage MCOV (L-L) | 528 V AC | 
| Maximum continuous operating voltage MCOV (L-G) | 264 V AC | 
| Nominal discharge current In (L-L) | 20 kA | 
| Nominal discharge current In (L-G) | 20 kA | 
| Mode of protection | L-L | 
| L-G | |
| Nominal voltage | 240/415 V AC | 
| Power distribution system | Delta | 
| Nominal frequency | 50/60 Hz | 
| Measured limiting voltage MLV (L-L) | 2450 V | 
| Measured limiting voltage MLV (L-G) | 1350 V | 
| Follow current (N-G) | 10 kA (264 V AC) | 
| SPD Type | 4CA | 
| UL indicator/remote signaling | |
| Operating voltage | 125 V AC | 
| AC operating current | 1 A AC | 
| UL connection data | |
| Tightening torque | 40 lbf-in. | 
| Conductor cross-section AWG | 12 ... 2 | 
| Standards/specifications | IEC 61643-11 | 
| Note | 2011 | 
| Standards/specifications | EN 61643-11 | 
| Note | 2012 | 
| Mounting type | DIN rail: 35 mm | 
| Item number | 2882653 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 1 pc | 
| Product key | CL1111 | 
| GTIN | 4046356098236 | 
| Weight per piece (including packing) | 1,326.6 g | 
| Weight per piece (excluding packing) | 1,183.89 g | 
| Country of origin | DE | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | No substance above 0.1 wt% | 
Compatible products