3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV and V range, unipolar as well as bipolar. Push-in connection technology, standard configuration.
Signal conditioners and measuring transducers for standard applications
Signal conditioners and measuring transducers isolate, convert, filter, and amplify signals as an interface between field and controller. MACX Analog und MINI Analog Pro offer flexible solutions for AI, AO, DI, temperature, frequency, and limit values. MINI Analog Pro is a user-friendly and space-saving product family. MACX Analog guarantees the safety of people, the environment, and the system with functional safety.
2-channel output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA ... 20 mA signals to a load in the safe area. 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.
Repeater power supply for supplying 2- and 4-conductor transmitters with Hart transparency and wide-range power supply, SIL 2 (1oo1)/SIL 3 (1oo2), screw connection
Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Freely programmable, 3-way electrical isolation, screw connection, SIL.
Temperature signal conditioner, configurable, for Pt 100 temperature sensors for the measuring range -50°C ... 200°C, screw connection
Repeater power supply, screw connection, input signal: (0)4 mA. .. 20 mA, output signal: (0)4 mA. ... 20 mA
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.
Constant voltage source with pluggable connection technology for the generation of a highly precise constant voltage of 15 V and for the supply of sensors without internal power supply. Screw connection technology.
NAMUR isolation switch amplifier for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive).. number of channels: 1, Standard configuration, 3-way isolation, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 2, Systematic Capability: 3, Screw connection
Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, screw connection, SIL, 3-way electrical isolation, standard configuration.
Your advantages with our highly compact MINI Analog Pro signal conditioners
- Easy installation with easily accessible terminal points, power bridging, and plug-in connection terminal blocks; also with Push-in connection technology
- Easy startup and servicing: measure signals without disconnecting current loops, plus optional disconnect function
- Wide range of parameterization options: easy configuration via DIP switches as well as advanced configuration via software or smartphone app without additional accessories
- Service-friendly with large-surface marking areas, status LEDs in every signal conditioner, and group error indication
- The highly compact MINI Analog Pro signal conditioners with plug-in connection technology are part of the COMPLETE line system
Easy installation and startup
1. Easy installation:
Clearly visible and easily accessible terminal points and FASTCON Pro plug-in connection terminal blocks.
2. Easy startup and servicing:
Interrupt signal and supply circuits in no time at all with the integrated disconnect function.
3. Measure current signals easily:
Measure current signals during operation, without disconnecting the current loop.
4. Wide range of parameterization options:
Easy configuration via DIP switches as well as advanced configuration via software or smartphone app without additional accessories.
MINI Analog Pro signal conditioners feature easy installation and startup
Highly compact MINI Analog Pro signal conditioners: Safely isolated from the field to the network
Modular signal conditioner combination with plug-in gateways
Safely isolated from field to network
The easy-to-attach gateways allow you to integrate any MINI Analog Pro signal conditioner with current or digital output into your network in a space-saving way. Signal-specific input cards are no longer required. MINI Analog Pro gateways for bus and network connection are available for the following protocols:
- PROFINET
- Modbus/RTU
- Modbus/TCP
- PROFIBUS DP
Your advantages with the gateways for bus and network communication
- Space-saving network integration of freely combinable signal conditioners with compact plug-in gateways
- Interference-free signal transmission to the CPU with safe electrical isolation, even between the individual channels
- Cost and space savings at control level, because signal-specific input cards are no longer required
- Easy startup and servicing: measure current signals during operation or read them off on your smartphone via NFC
- Quick parameterization via rotary coding switch, software, or the MINI Analog Pro app