SAC-3P-M 8MR-FS SCO/.../...
   - 
  Sensor/actuator cable
    
      1541940
      
      
    
  
      Sensor/actuator cable, 3-position, Plug angled M8, coding: A, on Socket straight M12 SPEEDCON, coding: A, cable length: Free input (0.2 ... 40.0 m)
Product details
| Product type | Sensor/actuator cable | 
| Application | Standard | 
| Number of positions | 3 | 
| No. of cable outlets | 1 | 
| Shielded | no | 
| Coding | A | 
| Insulation characteristics | |
| Overvoltage category | II | 
| Degree of pollution | 3 | 
| Flammability rating according to UL 94 | HB | 
| Seal material | NBR | 
| Material of grip body | TPU, hardly inflammable, self-extinguishing | 
| Contact material | CuSn | 
| Contact surface material | Ni/Au | 
| Contact carrier material | TPU GF | 
| Material for screw connection | Zinc die-cast, nickel-plated | 
| Insulation resistance | ≥ 100 MΩ | 
| Nominal voltage UN | 48 V AC | 
| 60 V DC | |
| Nominal current IN | 4 A | 
| Test voltage | 1500 V | 
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 100 | 
| Status display | no | 
| Status display present | no | 
| Conductor connection | |
| Tightening torque | 0.4 Nm (M12 connector) | 
| 0.2 Nm (M8 connectors) | |
| Connection 1 | |
| Type | Plug angled M8 | 
| Number of positions | 3 | 
| Coding type | A | 
| Connection 2 | |
| Type | Socket straight M12 SPEEDCON | 
| Number of positions | 3 | 
| Locking type | SPEEDCON | 
| Coding type | A | 
| Cable length | Free input (0.2 ... 40.0 m) | 
| PUR halogen-free black [PUR] | |
| Cable weight | 18 kg/km | 
| UL AWM Style | 20549 / 10493 (80°C/300 V) | 
| Number of positions | 3 | 
| Shielded | no | 
| Cable type | PUR halogen-free black [PUR] | 
| PUR halogen-free black PUR | |
| Conductor structure signal line | 32x 0.10 mm | 
| AWG signal line | 24 | 
| Conductor cross section | 3x 0.25 mm² (Signal line) | 
| Wire diameter incl. insulation | 1.17 mm ±0.02 mm | 
| External cable diameter | 3.60 mm ±0.15 mm | 
| Outer sheath, material | PUR | 
| External sheath, color | black-gray RAL 7021 | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | PP | 
| Single wire, color | brown, blue, black | 
| Thickness, insulation | ≥ 0.21 mm (Core insulation) | 
| Thickness, outer sheath | approx. 0.50 mm | 
| Overall twist | 3 wires, twisted | 
| Length of twist, overall twist | 40 mm | 
| Max. conductor resistance | ≤ 78 Ω/km (at 20 °C) | 
| Insulation resistance | ≥ 100 GΩ*km (at 20 °C) | 
| Nominal voltage, cable | ≤ 300 V | 
| Test voltage | ≥ 3000 V | 
| Smallest bending radius, fixed installation | 18 mm | 
| Smallest bending radius, movable installation | 36 mm | 
| Dynamic load capacity (bending) | Max. bending cycles: 10000000, Bending radius: 44 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² | 
| Dynamic load capacity (torsion) | Torsion: ±180 °/m, Torsion cycles: ≥2000000, Torsional frequency: 35 cycles/min. | 
| Halogen-free | in accordance with DIN VDE 0472 part 815 | 
| Flame resistance | in accordance with UL 758/1581 FT2 | 
| DIN EN 60332-2-2 (20 s) | |
| Resistance to oil | in accordance with DIN EN 60811-2-1 | 
| Other resistance | hydrolysis and microbe resistant | 
| Highly resistant to acids, alkaline solutions and solvents | |
| Resistant to salt water | |
| partly UV-resistant (in accordance with DIN EN ISO 4892-2-A) | |
| Special properties | Flexible cable conduit capable | 
| Silicone-free | |
| Free of substances which would hinder coating with paint or varnish | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) | 
| -25 °C ... 80 °C (Cable, flexible installation) | |
| PUR halogen-free yellow [240] | |
| Cable weight | 24 kg/km | 
| UL AWM Style | 20549 | 
| Number of positions | 3 | 
| Shielded | no | 
| Cable type | PUR halogen-free yellow [240] | 
| PUR halogen-free yellow 240 | |
| Conductor structure signal line | 32x 0.10 mm | 
| AWG signal line | 24 | 
| Conductor cross section | 3x 0.25 mm² (Signal line) | 
| Wire diameter incl. insulation | 1.17 mm ±0.02 mm | 
| External cable diameter | 4.40 mm ±0.15 mm | 
| Outer sheath, material | PUR | 
| External sheath, color | yellow | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | PP | 
| Single wire, color | brown, blue, black | 
| Thickness, insulation | ≥ 0.21 mm | 
| Thickness, outer sheath | approx. 0.90 mm | 
| Overall twist | 3 wires, twisted | 
| Length of twist, overall twist | 40 mm | 
| Max. conductor resistance | 78 Ω/km (at 20 °C) | 
| Insulation resistance | ≥ 1 GΩ*km (at 20 °C) | 
| Nominal voltage, cable | ≤ 300 V AC | 
| Test voltage | ≥ 3000 V AC (Spark test) | 
| Minimum bending radius, fixed installation | 5 x D | 
| Minimum bending radius, flexible installation | 10 x D | 
| Smallest bending radius, fixed installation | 22 mm | 
| Smallest bending radius, movable installation | 44 mm | 
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 10 x D, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² | 
| Halogen-free | in accordance with DIN VDE 0472 part 815 | 
| in accordance with EN 50267-2-1 | |
| Flame resistance | in accordance with UL 758/1581 FT2 | 
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C | 
| according to UL 758, 168 h at 60 °C | |
| Other resistance | hydrolysis and microbe resistant | 
| Resistant to salt water | |
| abrasion-resistant | |
| Low adhesion | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) | 
| -25 °C ... 80 °C (Cable, flexible installation) | |
| PUR halogen-free orange [180] | |
| Cable weight | 24 kg/km | 
| UL AWM Style | 20549 | 
| Number of positions | 3 | 
| Shielded | no | 
| Cable type | PUR halogen-free orange [180] | 
| PUR halogen-free orange 180 | |
| Conductor structure signal line | 32x 0.10 mm | 
| AWG signal line | 24 | 
| Conductor cross section | 3x 0.25 mm² (Signal line) | 
| Wire diameter incl. insulation | 1.17 mm ±0.02 mm (Signal line) | 
| External cable diameter | 4.40 mm ±0.15 mm | 
| Outer sheath, material | PUR | 
| External sheath, color | orange RAL 2003 | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | PP | 
| Single wire, color | brown, blue, black | 
| Thickness, insulation | ≥ 0.21 mm (Core insulation) | 
| approx. 0.90 mm (Outer cable sheath) | |
| Overall twist | 3 wires, twisted | 
| Max. conductor resistance | max. 78 Ω/km (at 20 °C) | 
| Insulation resistance | ≥ 10 GΩ*km (at 20 °C) | 
| Nominal voltage, cable | ≤ 300 V | 
| Test voltage | ≥ 3000 V | 
| Smallest bending radius, fixed installation | 22 mm | 
| Smallest bending radius, movable installation | 44 mm | 
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 44 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² | 
| Halogen-free | in accordance with DIN VDE 0472 part 815 | 
| Flame resistance | in accordance with DIN UL-Style 20549 | 
| in accordance with UL 758/1581 FT2 | |
| Resistance to oil | in accordance with DIN EN 60811-2-1 | 
| Other resistance | hydrolysis and microbe resistant | 
| Resistant to salt water | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) | 
| -25 °C ... 80 °C (Cable, flexible installation) | |
| PUR halogen-free gray [280] | |
| Cable weight | 18 kg/km | 
| UL AWM Style | 20549 / 10493 (80°C/300 V) | 
| Number of positions | 3 | 
| Shielded | no | 
| Cable type | PUR halogen-free gray [280] | 
| PUR halogen-free gray 280 | |
| Conductor structure signal line | 32x 0.10 mm | 
| AWG signal line | 24 | 
| Conductor cross section | 3x 0.25 mm² | 
| Wire diameter incl. insulation | 1.17 mm ±0.02 mm | 
| External cable diameter | 3.60 mm ±0.15 mm | 
| Outer sheath, material | PUR | 
| External sheath, color | gray RAL 7001 | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | PP | 
| Single wire, color | brown, blue, black | 
| Thickness, insulation | ≥ 0.21 mm (Core insulation) | 
| Thickness, outer sheath | approx. 0.50 mm | 
| Overall twist | 3 wires, twisted | 
| Length of twist, overall twist | 40 mm | 
| Max. conductor resistance | ≤ 78 Ω/km (at 20 °C) | 
| Insulation resistance | ≥ 100 GΩ*km (at 20 °C) | 
| Nominal voltage, cable | ≤ 300 V | 
| Test voltage | ≥ 3000 V | 
| Smallest bending radius, fixed installation | 18 mm | 
| Smallest bending radius, movable installation | 36 mm | 
| Dynamic load capacity (bending) | Max. bending cycles: 10000000, Bending radius: 44 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² | 
| Halogen-free | in accordance with DIN VDE 0472 part 815 | 
| Flame resistance | in accordance with UL 758/1581 FT2 | 
| DIN EN 60332-2-2 (20 s) | |
| Resistance to oil | in accordance with DIN EN 60811-2-1 | 
| Other resistance | hydrolysis and microbe resistant | 
| Highly resistant to acids, alkaline solutions and solvents | |
| Resistant to salt water | |
| partly UV-resistant (in accordance with DIN EN ISO 4892-2-A) | |
| Special properties | Flexible cable conduit capable | 
| Silicone-free | |
| Free of substances which would hinder coating with paint or varnish | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) | 
| -25 °C ... 80 °C (Cable, flexible installation) | |
| PVC black [PVC] | |
| Cable weight | 29 kg/km | 
| Number of positions | 3 | 
| Shielded | no | 
| Cable type | PVC black [PVC] | 
| PVC black PVC | |
| Conductor structure signal line | 14x 0.15 mm | 
| AWG signal line | 24 | 
| Conductor cross section | 3x 0.25 mm² (Signal line) | 
| Wire diameter incl. insulation | 1.17 mm ±0.05 mm | 
| External cable diameter | 4.20 mm ±0.15 mm | 
| Outer sheath, material | PVC | 
| External sheath, color | black RAL 9005 | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | PVC | 
| Single wire, color | brown, blue, black | 
| Thickness, insulation | ≥ 0.23 mm (Core insulation) | 
| Thickness, outer sheath | ≥ 0.76 mm | 
| Overall twist | 3 wires, twisted | 
| Max. conductor resistance | max. 79 Ω/km (at 20 °C) | 
| Insulation resistance | ≥ 100 MΩ*km (at 20 °C) | 
| Nominal voltage, cable | ≥ 300 V | 
| Test voltage | ≤ 3000 V | 
| Smallest bending radius, fixed installation | 13 mm | 
| Flame resistance | As per UL-Style 2464 | 
| Resistance to oil | EN 60811-2-1 | 
| Ambient temperature (operation) | -25 °C ... 80 °C (cable, fixed installation) | 
| -10 °C ... 80 °C (Cable, flexible installation) | |
| PVC gray [500] | |
| Cable weight | 29 kg/km | 
| Number of positions | 3 | 
| Shielded | no | 
| Cable type | PVC gray [500] | 
| PVC gray 500 | |
| Conductor type | Assembled shielded round cable | 
| Conductor structure signal line | 14x 0.15 mm | 
| AWG signal line | 24 | 
| Conductor cross section | 3x 0.25 mm² (Signal line) | 
| Wire diameter incl. insulation | 1.17 mm ±0.05 mm | 
| External cable diameter | 4.20 mm ±0.15 mm | 
| Outer sheath, material | PVC | 
| External sheath, color | gray RAL 7001 | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | PVC | 
| Single wire, color | brown, blue, black | 
| Thickness, insulation | ≥ 0.23 mm (Core insulation) | 
| Thickness, outer sheath | ≥ 0.76 mm | 
| Overall twist | 3 wires, twisted | 
| Max. conductor resistance | max. 79 Ω/km (at 20 °C) | 
| Insulation resistance | ≥ 100 MΩ*km (at 20 °C) | 
| Nominal voltage, cable | ≥ 300 V | 
| Test voltage | ≤ 3000 V | 
| Smallest bending radius, fixed installation | 13 mm | 
| Halogen-free | no | 
| Flame resistance | As per UL-Style 2464 | 
| Resistance to oil | in accordance with DIN EN 60811-2-1 | 
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) | 
| -25 °C ... 80 °C (Cable, flexible installation) | |
| Gray, highly flexible PUR [800] | |
| Note | Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments. | 
| Cable weight | 24 kg/km | 
| UL AWM Style | 20549 | 
| Number of positions | 3 | 
| Shielded | no | 
| Cable type | Gray, highly flexible PUR [800] | 
| Gray, highly flexible PUR 800 | |
| Conductor structure signal line | 32x 0.10 mm | 
| AWG signal line | 24 | 
| Conductor cross section | 3x 0.25 mm² (Signal line) | 
| Wire diameter incl. insulation | 1.2 mm ±0.05 mm (Signal line) | 
| External cable diameter | 4.30 mm ±0.2 mm | 
| Outer sheath, material | PUR | 
| External sheath, color | gray RAL 7001 | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | PP | 
| Single wire, color | brown, blue, black | 
| Overall twist | 3 wires, twisted | 
| Max. conductor resistance | approx. 76 Ω/km | 
| Insulation resistance | ≥ 20 MΩ*km | 
| Nominal voltage, cable | 300 V | 
| Test voltage | 2000 V | 
| Minimum bending radius, fixed installation | 4 x D | 
| Minimum bending radius, flexible installation | 7.5 x D | 
| Smallest bending radius, fixed installation | 18 mm | 
| Smallest bending radius, movable installation | 33 mm | 
| Dynamic load capacity (bending) | Max. bending cycles: 10000000, Bending radius: 7,5 x D, Traversing path: 5 m, Traversing rate: 3.3 m/s, Acceleration: 5 m/s² | 
| Max. bending cycles: 15000000, Bending radius: 50 mm, Traversing path: 0.9 m, Traversing rate: 5 m/s, Acceleration: 30 m/s² | |
| Dynamic load capacity (torsion) | Torsion: ±360 °/m, Torsion cycles: 1000000, Torsional frequency: 35 cycles/min. | 
| Halogen-free | in accordance with DIN VDE 0472 part 815 | 
| Flame resistance | in accordance with UL 758/1581 FT2 | 
| Resistance to oil | in accordance with DIN EN 60811-2-1 | 
| Other resistance | Highly resistant to acids, alkaline solutions and solvents | 
| Silicone-free | |
| Special properties | Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing | 
| Free from silicone and cadmium | |
| Free of substances which would hinder coating with paint or varnish | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) | 
| -25 °C ... 80 °C (Cable, flexible installation) | |
| Ambient conditions | |
| Degree of protection | IP65 | 
| IP67 | |
| IP68 | |
| Ambient temperature (operation) (male connector/female connector) | -25 °C ... 90 °C (Plug / socket) | 
| Standard designation | M12 connector | 
| Standards/specifications | IEC 61076-2-101 | 
| Standard designation | M8 connector | 
| Standards/specifications | IEC 61076-2-104 | 
| Item number | 1541940 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 25 pc | 
| Sales key | C1 - Sensor-Acuator Cable | 
| Product key | AF1BBA | 
| Customs tariff number | 85444290 | 
| Country of origin | PL | 
ECLASS
| ECLASS-13.0 | 27060311 | 
| ECLASS-15.0 | 27060311 | 
Compatible products
- 
    
      
 - 
    
      
UCT-WMT (23X4) - Conductor marker 0801453
 - 
    
      
UC-WMT (23X4) - Conductor marker 0819411
 - 
    
      
US-WMT (23X4) - Cable marker 0828769
 - 
    
      
WMTW (23X4)R - Cable marker 0831004
 - 
    
      
PROT-M12 MS-PA-CHAIN - Screw plug 1430899
 - 
    
      
SAC-M12-EXCLIP-F - Locking clip 1558991
 - 
    
      
B-STIFT - Marker pen 1051993
 - 
    
      
TSD 02 SAC - Torque screwdriver 1208487
 - 
    
      
SAC BIT M8-D10 - Tool 1208461
 - 
    
      
TSD 04 SAC - Torque screwdriver 1208429
 - 
    
      
TSD-M 1,2NM - Torque screwdriver 1212224
 - 
    
      
TSD-M SAC-BIT ADAPTER - Adapter insert 1212600
 - 
    
      
SAC BIT M12-D15 - Tool 1208432
 
Your advantages
Easy and safe: 100 % electrically tested plug-in components
        Save time, thanks to installation with SPEEDCON fast locking system
        Flexible solutions - configurable materials with variable cable types and cable lengths
        Phoenix Contact GmbH & Co. KG
        
        Flachsmarktstraße 8, D-32825 Blomberg