Type 2/3 surge protection, consisting of protective plug and base element with screw connection. For single-phase power supply network with integrated status indicator and remote signaling. Nominal voltage 230 V AC/DC.

Detalii despre produs




Vibration (operation) 5g (5 ... 500 Hz / 2.5 h / X, Y, Z)
Ambient temperature (operation) -40 °C ... 80 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Degree of protection IP20
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Permissible humidity (operation) 5 % ... 95 %
Altitude ≤ 2000 m (operating voltage remote contact ≤ 250 V)
≤ 6000 m (operating voltage remote contact ≤ 150 V)

Response time tA (L-N) ≤ 25 ns
Standby power consumption PC ≤ 26.4 mVA (at UREF)
≤ 26.4 mVA (at UC)
Response time tA (L-PE) ≤ 100 ns
TOV behavior at UT (L-PE) 457 V AC (5 s / withstand mode)
457 V AC (120 min / withstand mode)
1464 V AC (200 ms / safe failure mode)
Voltage protection level Up (N-PE) ≤ 1.4 kV
Response time tA (N-PE) ≤ 100 ns
Voltage protection level Up (L-N) ≤ 1.25 kV (at UOC)
≤ 1.4 kV (at In)
Combination wave UOC 6 kV
Nominal discharge current In (8/20) µs 5 kA
Direction of action 1L-N & N-PE
Voltage protection level Up (L-PE) ≤ 1.4 kV
Nominal voltage UN 240 V AC (TN-S)
240 V AC (TT)
Mode of protection L-N
L-PE
N-PE
Residual current IPE ≤ 5 µA
Maximum continuous voltage UC 264 V AC
Max. backup fuse with branch wiring 32 A (gG / B / C)
Reference test voltage UREF 264 V AC
Short-circuit current rating ISCCR 10 kA AC
Maximum discharge current Imax (8/20) µs 10 kA
TOV behavior at UT (N-PE) 1200 V AC (200 ms / safe failure mode)
Rated load current IL 26 A (at 30 °C)
Nominal frequency fN 50 Hz (60 Hz)
TOV behavior at UT (L-N) 400 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
Additional technical data
Maximum continuous voltage UC 275 V AC
240 V DC
Short-circuit current rating ISCCR 0.25 kA DC (Without additional backup fuse in the DC branch wiring)
5 kA DC (for 20 A gG / B backup fuse)
Impulse durability (wire-wire) D1 - 500 A
Residual voltage Ures (L-PE) ≤ 1.1 kV (at 2 kA)
≤ 1.1 kV (at 3 kA)
≤ 1.2 kV (at UOC = 4 kV)
Impulse durability (line-earth) D1 - 500 A
Pulse discharge current Iimp (10/350) µs (line-earth) 0.5 kA
Residual voltage Ures (N-PE) ≤ 1.1 kV (at 2 kA)
≤ 1.1 kV (at 3 kA)
≤ 1.2 kV (at UOC = 4 kV)
Pulse discharge current Iimp (10/350) µs (line-line) 0.5 kA
IEC test classification (in accordance with IEC 61643-21) D1
Mode of protection (DC+) - (DC-)
(DC+/DC-) - PE
Residual voltage Ures (L-N) ≤ 1.15 kV (at 2 kA)
≤ 1.25 kV (at 3 kA)
≤ 1.1 kV (at UOC = 4 kV)

Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Indicator/remote signaling
Operating current 0.5 A AC
0.5 A DC (75 V DC)
Switching function PDT contact
Connection name Remote fault indicator contact
Operating voltage 250 V AC
125 V DC (200 mA DC)

Desen dimensional
Horizontal pitch 1 Div.
Height 93.4 mm
Width 17.7 mm
Depth 74.5 mm (incl. DIN rail 7.5 mm)

CTI value of material 600
Color light grey RAL 7035
traffic grey A RAL 7042
Housing material PA 6.6-FR 20 % GF
PA 6.6-FR
Insulating material PA 6.6-FR 20 % GF
PA 6.6-FR
Flammability rating according to UL 94 V-0

Mounting type DIN rail: 35 mm

UL indicator/remote signaling
DC operating voltage 12 V DC (4 A)
24 V DC (2 A)
48 V DC (1 A)
AC operating voltage 250 V AC (0.5 A)
UL specifications
Power distribution system Single phase
DC
Measured limiting voltage MLV (L-G) 1180 V
Nominal discharge current In 5 kA
Nominal voltage 240 V DC
Nominal frequency 50/60 Hz
Rated load current IL 20 A
Measured limiting voltage MLV (L-N) 1150 V
SPD Type 4CA
Mode of protection L-N
L-G
N-G
(DC+) - (DC-)
(DC+) - G
(DC-) - G
Measured limiting voltage MLV (N-G) 1180 V
Maximum continuous operating voltage MCOV 264 V AC
240 V DC
UL connection data
Conductor cross section AWG 16 ... 12
Tightening torque 4.4 lbf-in.

Conductor cross section AWG 24 ... 12
Screw thread M3
Conductor cross section solid 0.2 mm2 ... 4 mm2
Tightening torque 0.5 Nm
Connection method Screw connection
Conductor cross section flexible 0.2 mm2 ... 2.5 mm2

Standards/specifications IEC 61643-11
EN 61643-11

Platform

EN type T2 / T3
Surge protection fault message Optical, remote indicator contact
IEC power supply system TT
TN-S
Number of positions 2
Type DIN rail module, two-section, divisible
Number of ports One
IEC test classification II / III
T2 / T3
Insulation characteristics
Pollution degree 2
Overvoltage category III


Cod comandă 2907919
Unitate de ambalare 5 pc
Cantitate minimă pentru comandă 1 pc
Pagina de catalog Pagina 83 (C-4-2019)
GTIN 4055626257457
Greutate pe bucată (inclusiv ambalajul) 96,6 GRM
Greutate pe bucată (fără ambalaj) 81,2 GRM
Cod tarifar vamal 85363030
Țara de origine DE



DNV GL

CCA

UL Recognized

KEMA-KEUR

cUL Recognized

IECEE CB Scheme

EAC

CSA

cULus Recognized

cULus Recognized

UL Recognized

cUL Recognized


Avantajele dumneavoastră

Easy to maintain due to consistently pluggable protection modules
Excellent level of information provided by mechanical/visual status indicator and remote indication contact
Your preferred connection technology can be selected as both screw connection and Push-in connection are available
Optimal additional protection of the industrial power supply for a longer service life and increased availability of the system
5-year warranty on your QUINT 4 power supply when installed together with PLT-SEC, see document in the download area