Hybrid motor starter - ELR H3-IES-PT- 24DC/500AC-2
Derating diagram
Conventional structure Main current path for contactor according to category 3
K1 + K2 = Emergency stop contactor K3 = Right contactor F4 = Motor protection relay
Conventional structure Control current path for contactor according to category 3
K1 + K2 = Emergency stop contactor K3 = Right contactor K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop F4 = Motor protection relay
Structure with CONTACTRON Main and control current path for ,3 in 1, hybrid motor starter according to category 3 K1 = ,3 in 1, hybrid motor starter K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop
Hybrid motor starter - ELR H3-IES-PT- 24DC/500AC-2
2903916
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
If this device is to be used in combination with the CrossPowerSystem power distribution board, the device mount for the 16 A fuse (order designation: EM-CPS-DA-22,5F/16A; order number: 1002668) is required in order to attach the hybrid motor starter to the power distribution board.
Product type
Hybrid motor starter
Operating mode
100% operating factor
Number of phases
3
Motor starter type
Direct starter
Maximum power dissipation for nominal condition
2.2 W
Switching frequency
≤ 2 Hz (Load-dependent)
Maximum power dissipation
3.3 W
Minimum power dissipation
1.1 W
Coordination type
1
Supply
Rated control circuit supply voltage US
24 V DC
Control supply voltage range
19.2 V DC ... 30 V DC
Rated control supply current IS
40 mA
Protective circuit
Surge protection
Reverse polarity protection
Insulation characteristics
Rated insulation voltage
500 V
Rated surge voltage
6 kV
Overvoltage category
III
Degree of pollution
2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuit
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Control
Input name
Control input
Rated actuating voltage UC
24 V DC
Triggering voltage range
19.2 V DC ... 30 V DC
Rated actuating current IC
5 mA (Input type 1)
Switching threshold
9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level
< 5 V DC (For EMERGENCY STOP)
Typical turn-off time
< 30 ms
Protective circuit
Reverse polarity protection
AC output
Rated operating voltage Ue
500 V AC
Operating voltage range
42 V AC ... 550 V AC
Rated operating current Ie
2.4 A (AC-51)
2.4 A (AC-53a)
Mains frequency
50/60 Hz
Load current range
180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2
Class 10A
Cooling time
20 min. (for auto reset)
Leakage current
0 mA
Protective circuit
Surge protection
Acknowledge output
Note
Confirmation: floating change-over contact, signal contact
Contact type
1 changeover contact
Switching capacity according to IEC 60947-5-1
3 A (230 V, AC15)
2 A (24 V, DC13)
Control circuits
Connection method
Push-in connection
Stripping length
10 mm
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Load circuit
Connection method
Push-in connection
Stripping length
10 mm
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Status display
Yellow LED
Operating voltage display
Green LED
Indication
Red LED
Width
22.5 mm
Height
107.5 mm
Depth
114 mm
Flammability rating according to UL 94
V0 (Housing)
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m
UKCA
Certificate
UKCA-compliant
ATEX
Identification
II (2) G [Ex e] [Ex d] [Ex px]
II (2) D [Ex t] [Ex p]
Certificate
PTB 07 ATEX 3145
UL approval
Certificate
NLDX.E228652
Safety Integrity Level (SIL, IEC 61508)
Identification
≤ 3
Note
Safe shutdown
Safety Integrity Level (SIL, IEC 61508)
Identification
2
Note
Motor protection
Performance Level (ISO 13849)
Identification
≤ e
Note
Safe shutdown
Category (ISO 13849)
Identification
≤ 3
Note
Safe shutdown
UL data
SCCR
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA
2.4 A (500 V AC)
Group installation
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category code
NLDX
Standards/regulations
Standards/regulations
IEC 60947-1
IEC 60947-4-2
IEC 61508
ISO 13849
Mounting type
DIN rail mounting
Assembly instructions
alignable, for spacing see derating
Mounting position
vertical (horizontal DIN rail, motor output below)
N.º de artigo
2903916
Pcs./Emb
1 Unidade
Quantidade mínima de pedido
1 Unidade
Observação
Produção ligada a pedido (sem devolução)
Chave comercial
CK7
Chave de produto
CK7411
Página de catálogo
Página 34 (C-5-2019)
GTIN
4046356771399
Peso por unidade (inclusive embalagem)
279,4 g
Peso por unidade (excluindo embalagem)
259 g
Número do imposto alfandegário
85371098
País de origem
DE
ECLASS
ECLASS-9.0
27370905
ECLASS-10.0.1
27370905
ECLASS-11.0
27370905
ETIM
ETIM 8.0
EC001037
UNSPSC
UNSPSC 21.0
25173900
IECEE CB Scheme
Approval ID: DE1-55728
EAC
Approval ID: RU*C-DE.*08.B.00520*
UL Listed
Approval ID: FILE E 323771
CCC
Approval ID: 2016010304871315
cUL Listed
Approval ID: FILE E 323771
cUL Listed
Approval ID: FILE E 228652
UL Listed
Approval ID: FILE E 228652
ATEX
Approval ID: PTB 07 ATEX 3145
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”