Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|---|
Use in potentially explosive areas is not permitted in China. |
Ambient temperature (operation) | -20 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Degree of protection | IP20 |
Noise immunity | EN 61000-6-2:2005 |
Bit distortion, input | ± 35 % (permitted) |
---|---|
Bit distortion, output | < 6.25 % |
Electrical isolation | VCC // RS-485 |
Test voltage data interface/power supply | 1.5 kVrms (50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC directive 89/336/EC |
Noise emission | EN 55011 |
Net weight | 263.9 g |
Housing material | PA 6.6-FR |
Color | green |
MTBF | 307 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
64 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
MTTF | 614 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
272 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
113 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Nominal supply voltage | 24 V DC (With UL approval) |
---|---|
Supply voltage range | 18 V DC ... 32 V DC |
Max. current consumption | 145 mA |
Typical current consumption | 85 mA (24 V DC) |
170 mA (According to UL Listed, 24 V DC) | |
110 mA (According to UL Recognized, 24 V DC) | |
Connection method | COMBICON plug-in screw terminal block |
Interface 1 | PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control |
---|---|
Operating mode | Semi-duplex |
Connection method | D-SUB-9 female connector |
File format/coding | UART (11 Bit, NRZ) |
Data direction switching | Automatic control |
Transmission medium | Copper |
Transmission length | ≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable) |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Serial transmission speed | ≤ 12 Mbps |
No. of channels | 2 |
---|---|
Wavelength | 1300 nm |
Transmission length incl. 3 dB system reserve | 25 km (With F-G 50/125 0.7 dB/km at 1300 nm) |
22 km (with F-G 62.5/125 0.8 dB/km at 1300 nm) | |
45 km (With F-E 9/125 0,4 dB/km at 1300 nm) | |
Transmission medium | Multi-mode fiberglass |
Single-mode fiberglass | |
Transmission protocol | Protocol-transparent to the RS-485 interface |
Connection method | SC duplex |
Output name | Relay output |
---|---|
Output description | Alarm output |
Number of outputs | 1 |
Maximum switching voltage | 60 V DC |
42 V AC | |
Limiting continuous current | 1 A |
Designation | CE |
---|---|
Identification | CE-compliant |
Designation | EAC |
Identification | EAC |
Designation | ATEX |
Identification | II 3 G Ex nA nC IIC T4 Gc X |
Additional text | Please follow the special installation instructions in the documentation! |
Designation | UL, USA/Canada |
Identification | 508 Listed |
508 Recognized | |
Designation | Corrosive gas test |
Identification | ISA-S71.04-1985 G3 Harsh Group A |
Electromagnetic compatibility | Conformance with EMC directive 89/336/EC |
---|---|
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result | 15g, 11 ms period, half-sine shock pulse |
Noise emission | EN 55011 |
Noise immunity | EN 61000-6-2:2005 |
Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Standards/regulations | EN 61000-4-3 |
EN 61000-4-4 | |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | ± 1 kV |
Standards/regulations | EN 55011 |
EN 61000-4-6 |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 19170132 |
---|---|
eCl@ss 11.0 | 19170132 |
eCl@ss 4.0 | 27230200 |
eCl@ss 4.1 | 27230200 |
eCl@ss 5.0 | 27230200 |
eCl@ss 5.1 | 27230200 |
eCl@ss 6.0 | 19179200 |
eCl@ss 7.0 | 19179290 |
eCl@ss 8.0 | 19179290 |
eCl@ss 9.0 | 19170114 |
ETIM 2.0 | EC001423 |
---|---|
ETIM 3.0 | EC001423 |
ETIM 4.0 | EC001423 |
ETIM 5.0 | EC000310 |
ETIM 6.0 | EC001467 |
ETIM 7.0 | EC001467 |
UNSPSC 6.01 | 30211506 |
---|---|
UNSPSC 7.0901 | 39121008 |
UNSPSC 11 | 39121008 |
UNSPSC 12.01 | 39121008 |
UNSPSC 13.2 | 43222604 |
UNSPSC 18.0 | 43223323 |
UNSPSC 19.0 | 43223323 |
UNSPSC 20.0 | 43223323 |
UNSPSC 21.0 | 43223323 |
"$pageName" on