FO converters - PSI-MOS-RS422/FO 1300 E - 2708575

Fiber optic converter with integrated optical diagnostics, alarm contact, for RS-422/RS-485 4 wire/ INTERBUS up to 2 Mbps, termination device with one fiber optic interface (SC duplex), 1300 nm, for fiberglass cable

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Use in potentially explosive areas is not permitted in China.
Back to top

Dimensions

Width 35 mm
Height 105 mm
Depth 103 mm
Back to top

Ambient conditions

Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 30 % ... 95 % (non-condensing)
Altitude ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Degree of protection IP20
Noise immunity EN 61000-6-2:2005
Back to top

General

Transmission channels 2 (1/1) RD, TD, full duplex
Bit distortion, input ± 35 % (permitted)
Bit distortion, output < 6.25 %
Electrical isolation VCC // RS-422
Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive 89/336/EC
Noise emission EN 55011
Net weight 190.68 g
Housing material PA 6.6-FR
Color green
MTBF 544 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
113 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Back to top

Power supply

Nominal supply voltage 24 V DC (With UL approval)
Supply voltage range 18 V DC ... 32 V DC
Typical current consumption 110 mA (24 V DC)
Connection method COMBICON plug-in screw terminal block
Back to top

Interfaces

Interface 1 RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Operating mode full duplex
Connection method Pluggable screw connection
Transmission medium Copper
Transmission length ≤ 1000 m (depending on the data rate, with shielded, twisted data cable)
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Serial transmission speed ≤ 2 Mbps
Back to top

Optical interface FO

No. of channels 1
Wavelength 1300 nm
Transmission length incl. 3 dB system reserve 27 km (With F-G 50/125 0.7 dB/km at 1300 nm)
22 km (with F-G 62.5/125 0.8 dB/km at 1300 nm)
45 km (With F-E 9/125 0,4 dB/km at 1300 nm)
Transmission medium Multi-mode fiberglass
Single-mode fiberglass
Transmission protocol Transparent to protocol for RS-422 interface
Connection method SC duplex
Back to top

Digital outputs

Output name Relay output
Output description Alarm output
Number of outputs 1
Maximum switching voltage 60 V DC
42 V AC
Limiting continuous current 1 A
Back to top

Conformance/approvals

Designation CE
Identification CE-compliant
Designation ATEX
Identification  II 3 G Ex nA nC IIC T4 Gc X
Additional text Please follow the special installation instructions in the documentation!
Designation UL, USA/Canada
Identification 508 Listed
508 Recognized
Designation Corrosive gas test
Identification ISA-S71.04-1985 G3 Harsh Group A
Designation Shipbuilding
Identification DNV GL
Temperature B
Humidity A
Vibration A
EMC B
Enclosure Required protection according to the Rules shall be provided upon installation on board
Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC directive 89/336/EC
Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result 5g, 10...150 Hz, 2.5 h, in XYZ direction
Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result 15g, 11 ms period, half-sine shock pulse
Noise emission EN 55011
Noise immunity EN 61000-6-2:2005
Free from substances that could impair the application of coating according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
Contact discharge ± 6 kV
Standards/regulations EN 61000-4-3
EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal ± 1 kV
Standards/regulations EN 55011
EN 61000-4-6
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 19170132
eCl@ss 11.0 19170132
eCl@ss 4.0 27230200
eCl@ss 4.1 27230200
eCl@ss 5.0 27230200
eCl@ss 5.1 27230200
eCl@ss 6.0 19179200
eCl@ss 7.0 19179290
eCl@ss 8.0 19179290
eCl@ss 9.0 19170114
Back to top

ETIM

ETIM 2.0 EC001423
ETIM 3.0 EC001423
ETIM 4.0 EC001423
ETIM 5.0 EC000310
ETIM 6.0 EC001467
ETIM 7.0 EC001467
Back to top

UNSPSC

UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 43222604
UNSPSC 18.0 43223323
UNSPSC 19.0 43223323
UNSPSC 20.0 43223323
UNSPSC 21.0 43223323
Back to top