Width | 35 mm |
---|---|
Height | 99 mm |
Depth | 95 mm |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Nominal input voltage range | 100 V AC ... 240 V AC |
---|---|
Input voltage range | 85 V AC ... 264 V AC |
AC frequency range | 45 Hz ... 65 Hz |
Current consumption | 0.75 A (120 V AC) |
0.45 A (230 V AC) | |
Nominal power consumption | 90 VA |
Inrush current | < 15 A (0.6 A2s) |
Mains buffering time | typ. 35 ms (120 V AC) |
typ. 150 ms (230 V AC) | |
Input fuse | 3.15 A (slow-blow, internal) |
Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Nominal output voltage | 24 V DC ±1 % |
---|---|
Nominal output current (IN) | 1.5 A (-25 °C ... 60 °C) |
POWER BOOST (IBoost) | 2 A (-25°C ... 40°C permanent ) |
Derating | 60 °C ... 70 °C (2.5%/K) |
Connection in parallel |
Yes, for redundancy and increased capacity. Maximum of 2 devices for redundancy on DIN rail connector. |
Connection in series | No |
Feedback voltage resistance | 35 V DC |
Protection against overvoltage at the output (OVP) | < 30 V DC |
Max. capacitive load | unlimited |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
< 3 % (change in load, dynamic 10 % ... 90 %) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 40 mVPP (20 MHz) |
Output power | 36 W |
Typical response time | < 0.5 s |
Peak switching voltages idling | < 20 mVPP (20 MHz) |
Peak switching voltages nominal load | < 20 mVPP (20 MHz) |
Maximum power dissipation in no-load condition | 1.5 W |
Power loss nominal load max. | 6.5 W |
Net weight | 0.25 kg |
---|---|
Operating voltage display | Green LED |
Efficiency | > 84 % (for 230 V AC and nominal values) |
MTBF (IEC 61709, SN 29500) | > 2789000 h (40 °C) |
Insulation voltage input/output | 4 kV (type test) |
3 kV (routine test) | |
Degree of protection | IP20 |
Protection class | II (in closed control cabinet) |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Connection method | Pluggable screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Connection method | Pluggable screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section solid min. | 0.2 mm² |
---|---|
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Screw thread | M3 |
EMC requirements for noise immunity | EN 61000-6-1 |
---|---|
EN 61000-6-2 | |
EMC requirements for noise emission | EN 61000-6-3 |
EN 61000-6-4 | |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | EN 60950-1 (SELV) and EN 60204 (PELV) |
EN 60204 (PELV) | |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Rail applications | EN 50121-4 |
UL approvals | UL/C-UL listed UL 508 |
---|---|
UL/C-UL Recognized UL 60950-1 | |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Electrostatic discharge | EN 61000-4-2 |
Electromagnetic HF field | EN 61000-4-3 |
Fast transients (burst) | EN 61000-4-4 |
Surge voltage load (surge) | EN 61000-4-5 |
Conducted interference | EN 61000-4-6 |
Voltage dips | EN 61000-4-11 |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 25; |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 27040701 |
---|---|
eCl@ss 11.0 | 27040701 |
eCl@ss 4.0 | 27040700 |
eCl@ss 4.1 | 27040700 |
eCl@ss 5.0 | 27049000 |
eCl@ss 5.1 | 27049000 |
eCl@ss 6.0 | 27049000 |
eCl@ss 7.0 | 27049002 |
eCl@ss 9.0 | 27040701 |
ETIM 2.0 | EC001039 |
---|---|
ETIM 3.0 | EC001039 |
ETIM 4.0 | EC000599 |
ETIM 5.0 | EC002540 |
ETIM 6.0 | EC002540 |
ETIM 7.0 | EC002540 |
UNSPSC 6.01 | 30211502 |
---|---|
UNSPSC 7.0901 | 39121004 |
UNSPSC 11 | 39121004 |
UNSPSC 12.01 | 39121004 |
UNSPSC 13.2 | 39121004 |
UNSPSC 18.0 | 39121004 |
UNSPSC 19.0 | 39121004 |
UNSPSC 20.0 | 39121004 |
UNSPSC 21.0 | 39121004 |