Type 2 surge protection plug - F-MS 1100 ST - 2909844

Surge protection plug type 2, spark gap with high insulation voltage strength, used only as replacement plug for the corresponding complete item.

Price:

Overview

Technical data

Accessories

Downloads

Drawings



Dimensional drawing  

Dimensional drawing

Circuit diagram  

Circuit diagram



Back to top

Dimensions

Height 52.4 mm
Width 17.5 mm
Depth 55.3 mm
Horizontal pitch 1 Div.
Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -40 °C ... 80 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 5000 m (amsl (above mean sea level))
Permissible humidity (operation) 5 % ... 95 %
Shock (operation) 25g
Vibration (operation) 5g
Back to top

General

IEC test classification II
T2
EN type T2
Mode of protection L-PE (for IT systems without N in series with a VAL-MS plug)
Mounting type on base element
Color jet black RAL 9005
Housing material PA 6.6
Degree of pollution 2
Flammability rating according to UL 94 V-0
Type DIN rail module, two-section, divisible
Number of positions 1
Surge protection fault message optical
Back to top

Additional descriptions

Note The F-MS 1100 ST protective plug is only to be used with a VAL-MS 400 ST in series connection. It is not designed for direct use on mains voltage.
Uagn > 1100 V
At altitudes > 2000 m (amsl), a lateral distance of 2 mm must be maintained between live and grounded parts.
Back to top

Protective circuit

Nominal frequency fN 50 Hz
60 Hz
Maximum continuous voltage UC 260 V AC
Residual current IPE ≤ 3 µA
Nominal discharge current In (8/20) µs 20 kA
Maximum discharge current Imax (8/20) µs 40 kA
Short-circuit current rating ISCCR 25 kA (in series with a VAL-MS plug)
Voltage protection level Up ≤ 3 kV
Front of wave sparkover voltage at 6 kV (1.2/50) µs ≤ 3 kV
Response time tA ≤ 100 ns
Back to top

Connection data

Connection method pluggable
Back to top

Standards and Regulations

Standards/regulations IEC 61643-11 2011
EN 61643-11 2012
Back to top

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27130890
eCl@ss 11.0 27130890
eCl@ss 6.0 27130800
eCl@ss 7.0 27130890
eCl@ss 8.0 27130890
eCl@ss 9.0 27130890
Back to top

ETIM

ETIM 5.0 EC002496
ETIM 6.0 EC002497
ETIM 7.0 EC002497
Back to top