Type 3 surge protection plug - PLT-SEC-T3-230-P - 2905235

Replacement plug for type 3 device protection from the PLUGTRAB SEC T3 product range. 230 V nominal voltage.

Price:

Save money: Best price starts from {0} pieces!

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Dimensional drawing  

Dimensional drawing

Circuit diagram  

Circuit diagram



Back to top

Dimensions

Height 60.9 mm
Width 17.5 mm
Depth 44.8 mm
Horizontal pitch 1 Div.
Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -40 °C ... 80 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation) 5 % ... 95 %
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation) 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z)
Back to top

General

EN type T3
IEC power supply system TN-S
TT
Mode of protection L-N
L-PE
N-PE
(L+) - (L-)
(L+/L-) - PE
Mounting type on base element
Color light grey RAL 7035
Housing material PA 6.6-FR 20 % GF
PA 6.6-FR
Degree of pollution 2
Flammability rating according to UL 94 V-0
Type Male
Number of positions 2
Surge protection fault message optical
Back to top

Protective circuit

Nominal voltage UN 230 V AC (TN-S)
230 V AC (TT - only in use with RCD)
Nominal frequency fN 50 Hz (60 Hz)
Maximum continuous voltage UC 264 V AC
230 V DC
Residual current IPE ≤ 5 µA
Nominal discharge current In (8/20) µs 3 kA
Standby power consumption PC ≤ 275 mVA (at UREF)
≤ 300 mVA (at UC)
Reference test voltage UREF 255 V AC
Combination wave UOC 6 kV
Voltage protection level Up (L-N) ≤ 1.35 kV
Voltage protection level Up (L-PE) ≤ 1.5 kV
Voltage protection level Up (N-PE) ≤ 1.5 kV
TOV behavior at UT (L-N) 440 V AC (5 s / withstand mode)
440 V AC (120 min / withstand mode)
TOV behavior at UT (L-PE) 440 V AC (5 s / withstand mode)
440 V AC (120 min / withstand mode)
1455 V AC (200 ms / safe failure mode)
TOV behavior at UT (N-PE) 1200 V AC (200 ms / safe failure mode)
Response time tA (L-N) ≤ 25 ns
Response time tA (L-PE) ≤ 100 ns
Response time tA (N-PE) ≤ 100 ns
Short-circuit current rating ISCCR 1.5 kA AC
0.25 kA DC
Back to top

Connection data

Connection method pluggable
Back to top

UL specifications

SPD Type 4CA
Maximum continuous operating voltage MCOV 255 V AC
230 V DC
Nominal voltage 230 V DC
Mode of protection L-N
L-G
N-G
(L+) - (L-)
(L+) - G
(L-) - G
Power distribution system Single phase
Nominal frequency 50/60 Hz
Measured limiting voltage MLV (L-N) 1290 V
Measured limiting voltage MLV (L-G) 1310 V
Measured limiting voltage MLV (N-G) 1310 V
Measured limiting voltage MLV (L+) - (L-) 1290 V
Measured limiting voltage MLV (L+) - G 1310 V
Measured limiting voltage MLV (L-) - G 1310 V
Nominal discharge current In 3 kA
Back to top

Standards and Regulations

Standards/specifications IEC 61643-11 2011
EN 61643-11 2012
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

ECLASS

ECLASS 4.0 27130800
ECLASS 4.1 27130800
ECLASS 5.0 27130800
ECLASS 5.1 27130800
ECLASS 6.0 27130800
ECLASS 7.0 27130806
ECLASS 9.0 27130890
Back to top

ETIM

ETIM 6.0 EC000942
ETIM 7.0 EC000942
Back to top

UNSPSC

UNSPSC 13.2 39121620
UNSPSC 18.0 39121620
UNSPSC 19.0 39121620
UNSPSC 20.0 39121620
UNSPSC 21.0 39121620
Back to top

PHOENIX CONTACT

586 Fulling Mill Road
Middletown, PA 17057
(800) 888-7388

Service


Surge protection for the power supply

Learning module on surge protection for the power supply.


Surge protection reinvented

Safe Energy Control (SEC) technology offers remarkably high durability in surge protection for your application.

  • Create PDF
  • Send by Email
  • Feedback