I/O extension module - RAD-DOR4-IFS - 2901536

Radioline - I/O extension module, 4 digital relay outputs (5 A, 250 V AC/DC)

Price:

Save money: Best price starts from {0} pieces!

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Application drawing  

Application drawing
Wireless module in I/O data mode

Application drawing  

Application drawing
Wireless module in PLC/Modbus RTU mode



Functional drawing  

Functional drawing
Assignment of digital inputs and digital outputs

Dimensional drawing  

Dimensional drawing
Slim design



Circuit diagram  

Circuit diagram

Schematic diagram  

Schematic diagram
Function elements



Schematic diagram  

Schematic diagram
DIP switches

Schematic diagram  

Schematic diagram
Thumb wheel



Schematic diagram  

Schematic diagram
LED indicators

Back to top

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Use in potentially explosive areas is not permitted in China.
Back to top

Dimensions

Width 17.5 mm
Height 113 mm
Depth 114.5 mm
Dimensional drawing
Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -40 °C ... 70 °C (>55°C derating)
-40 °F ... 158 °F (>131°F derating)
Ambient temperature (storage/transport) -40 °C ... 85 °C
-40 °F ... 185 °F
Permissible humidity (operation) 20 % ... 85 %
Permissible humidity (storage/transport) 20 % ... 85 %
Altitude 2000 m
Vibration (operation) in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
Shock 16g, 11 ms
Back to top

General

Set consists of 2709561 ME 17,5 TBUS 1,5/ 5-ST-3,81 GN
Overvoltage category II
Mounting position any
Assembly instructions on standard DIN rail NS 35 in accordance with EN 60715
Degree of pollution 2
Housing material PA 6.6-FR
Flammability rating according to UL 94 V0
MTTF 1087 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
523 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
204 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Weight 179.4 g
Back to top

Supply

Supply voltage range 19.2 V DC ... 30.5 V DC (DIN rail connector)
Max. current consumption ≤ 55 mA (At 24 V DC, at 25°C)
Transient surge protection Yes
Back to top

Digital outputs

Number of outputs 4
Contact type Changeover contact
Contact material AgSnO2
Maximum switching voltage 250 V AC/DC
Min. switching current ≥ 10 mA
Max. switching current 5 A (per channel)
Mechanical service life 1x 107 cycles
Electrical service life 1x 105 cycles (At 5 A, 250 V AC, ohmic)
2x 105 cycles (At 2 A, 250 V AC, cosφ 0.4)
2x 105 cycles (At 1 A, 24 V DC, L/R = 48 ms)
Maximum switching frequency 2 Hz
Switching capacity 120 W (24 V DC)
120 W (30 V DC)
20 W (48 V DC)
18 W (60 V DC)
22 W (110 V DC)
40 W (220 V DC)
42 W (250 V DC)
1250 VA
Behavior of the outputs (adjustable via DIP switch) Hold / Reset
Back to top

Electrical isolation

Digital I/O 300 V (Rated insulation voltage (in each case between the digital outputs // TBUS supply, reinforced insulation according to EN 61010))
Back to top

Test voltage

Digital I/O 2.5 kV AC (50 Hz, 1 min.)
Back to top

Connection data

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 7 mm
Tightening torque 0.6 Nm
Screw thread M3
Back to top

Status indicator

Status display Green LED (supply voltage, PWR)
Green LED (bus communication, DAT)
Red LED (periphery error, ERR)
Yellow LED (digital output, DO1)
Yellow LED (digital output, DO2)
Yellow LED (digital output, DO3)
Yellow LED (digital output, DO4)
Back to top

Conformance/approvals

Designation CE
Certificate CE-compliant
Designation EAC
Identification EAC
Designation ATEX
Identification  II 3 G Ex nA nC IIC T4 Gc
Certificate IBExU 15 ATEX B008 X
Additional text Please follow the special installation instructions in the documentation!
Designation IECEx
Identification Ex nA nC IIC T4 Gc
Certificate IECEx IBE 13.0019X
Designation EAC Ex
Identification 2Ex nA nC IIC T4 Gc X
Certificate RU C-DE.HB49.B.00033/20
Designation UL, USA / Canada
Identification 508 Listed
Class I, Div. 2, Groups A, B, C, D T4A
Class I, Zone 2, IIC T4
Designation Wireless approval South Korea, KC
Certificate R-R-PCK-2901536
Designation Corrosive gas test
Identification ISA-S71.04-1985 G3 Harsh Group A
Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Standards/specifications EMC Directive 2014/30/EU EN 61000-6-2
EMC Directive 2014/30/EU EN 61000-6-4
Ex Directive (ATEX) EN 60079-0
Ex Directive (ATEX) EN-60079-15
Shock 16g, 11 ms
Vibration (operation) in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Articles in set

DIN rail bus connectors ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561

DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.

Back to top

Classifications

ECLASS

ECLASS 10.0.1 27242604
ECLASS 11.0 27242604
ECLASS 4.0 27230200
ECLASS 4.1 27230200
ECLASS 5.0 27242200
ECLASS 5.1 27242200
ECLASS 6.0 27242600
ECLASS 7.0 27242604
ECLASS 9.0 27242604
Back to top

ETIM

ETIM 3.0 EC001423
ETIM 4.0 EC000310
ETIM 6.0 EC001599
ETIM 7.0 EC001599
Back to top

UNSPSC

UNSPSC 6.01 30211506
UNSPSC 7.0901 43223108
UNSPSC 11 39121008
UNSPSC 12.01 43223108
UNSPSC 13.2 32151602
UNSPSC 18.0 32151602
UNSPSC 19.0 32151602
UNSPSC 20.0 32151602
UNSPSC 21.0 32151602
Back to top

PHOENIX CONTACT

586 Fulling Mill Road
Middletown, PA 17057
(800) 888-7388

  • Create PDF
  • Send by Email
  • Feedback