Sensor/actuator cable - SAC-12P-MS/ 2,5-35T/FS SH SCO - 1424547

No picture available

Sensor/actuator cable, 12-position, PUR/PVC, black RAL 9005, shielded, cable length: 2.5 m

Price:

Overview

Technical data

Approvals

Downloads

Drawings



Cable cross section  

Cable cross section
Black PUR/PVC twisted pair [35T]

Back to top

Dimensions

Length of cable 2.5 m
Back to top

General

Rated voltage 30 V AC
30 V DC
Number of positions 12
Back to top

Cable

Cable type Black PUR/PVC twisted pair
Cable type (abbreviation) 35T
Cable abbreviation LSPYwC11Y
UL AWM style 20233 / 1061 (80°C/300 V)
Conductor cross section 12x 0.14 mm² (Signal line)
AWG signal line 26
Conductor structure signal line 18x 0.10 mm
Core diameter including insulation 1 mm ±0.05 mm (Signal line)
Wire colors White-brown, green-yellow, gray-pink, blue-red, black-violet, gray/pink-red/blue
Twisted pairs 2 cores to the pair
Overall twist Six pairs around the filler to the core
Shielding Tinned copper braided shield
Optical shield covering 85 %
External sheath, color black RAL 9005
External cable diameter D 8.5 mm ±0.2 mm
Minimum bending radius, fixed installation 5 x D
Minimum bending radius, flexible installation 10 x D
Number of bending cycles 2000000
Bending radius 85 mm
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 10 m/s²
Cable weight 87 kg/km
Outer sheath, material PUR
Material, inner sheath PVC
Material conductor insulation PVC
Conductor material Tin-plated Cu litz wires
Insulation resistance ≥ 10 MΩ*km (at 20 °C)
Conductor resistance ≤ 142 Ω/km (at 20 °C)
Nominal voltage, cable 42 V AC
Test voltage, cable 1500 V AC
Special properties Flexible cable conduit capable
Flame resistance According to DIN EN 60332-1-2
According to VW-1
Resistance to oil in accordance with DIN EN 60811-2-1
Other resistance hydrolysis and microbe resistant according to EN 50396
Ambient temperature (operation) -30 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”