new

Extension module - AXC F IL ADAPT - 1020304

Right-alignable Inline adapter terminal (INTERBUS master) for one PLCnext Control device for setting up a PLCnext Technology Inline station

Price:

Overview

Technical data

Accessories

Downloads

Drawings



Dimensional drawing  

Dimensional drawing

Back to top

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Dimensional drawing
Width 12.2 mm
Height 119.8 mm
Depth 71.5 mm
Back to top

Ambient conditions

Ambient temperature (operation) -25 °C ... 55 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 10 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection IP20
Back to top

Connection data

Designation Inline connector
Connection method Spring-cage connection
Conductor cross section solid min. 0.08 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.08 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 28
Conductor cross section AWG max. 16
Stripping length 8 mm
Back to top

General

Mounting type DIN rail mounting
Net weight 66 g
Diagnostics messages Bus error in INTERBUS Yes
Peripheral fault in INTERBUS Yes
Mounting type DIN rail mounting
Back to top

Data interfaces

Interface INTERBUS local bus (master)
Number 1
Connection method Inline data jumper
Back to top

Power supply for module electronics

Supply voltage range
Current consumption 20 mA
Back to top

Inline potentials

Designation 24 V supply UILC
Supply voltage 24 V DC -15 % / +20 % (acc. to EN 61131-2)
Current consumption 20 mA
Designation 7.5 V communications power UL (potential jumper)
Supply voltage 7.5 V DC ±5 %
Power supply unit max. 0.8 A DC (observe derating)
Designation 24 V analog supply UANA (potential jumper)
Supply voltage 24 V DC -15 % / +20 %
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unit 0.5 A DC (observe derating)
Designation 24 V main supply UM
Supply voltage 24 V DC -15 % / +20 % (acc. to EN 61131-2)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unit max. 8 A DC (sum of UM + US)
Designation 24 V segment supply US
Supply voltage 24 V DC -15 % / +20 % (in accordance with EN 61131)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply unit max. 8 A (sum of UM + US)
Type of protection Polarity reversal protection of the supply voltage
Transient protection
Back to top

Axioline potentials

Supply voltage 24 V DC
Supply voltage range
Back to top

Standards and Regulations

Mechanical tests Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 6.0 27242600
eCl@ss 7.0 27242608
eCl@ss 8.0 27242608
eCl@ss 9.0 27242608
Back to top

ETIM

ETIM 5.0 EC001604
ETIM 6.0 EC001604
ETIM 7.0 EC001604
Back to top

PHOENIX CONTACT

586 Fulling Mill Road
Middletown, PA 17057
(800) 888-7388

  • Create PDF
  • Send by Email
  • Feedback