Repeater - PSI-REP-PROFIBUS/12MB - 2708863

Modular repeater for electrical isolation and range increase for PROFIBUS up to 12 Mbps, 4-way isolation, rail-mountable, supply 24 V DC

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Application drawing  

Application drawing
Branch line

Application drawing  

Application drawing
Line structure



Application drawing  

Application drawing
Star structure

Application drawing  

Application drawing
Tree structure



Block diagram  

Block diagram

Dimensional drawing  

Dimensional drawing
Housing dimensions



Schematic diagram  

Schematic diagram
Front view

Back to top

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Dimensional drawing
Caption Housing dimensions
Width 35 mm
Height 99 mm
Depth 105 mm
Back to top

Ambient conditions

Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 30 % ... 95 % (non-condensing)
Altitude ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
≤ 2000 m (Restrictions for ATEX applications)
Degree of protection IP20
Noise immunity EN 61000-4-2
Back to top

General

Transmission channels 2 (1/1), TD, RD, half duplex
Bit delay 1 bit (Direct mode)
Bit distortion, input max. ± 35 %
Bit distortion, output < 6.25 %
Electrical isolation VCC // TBUS // PROFIBUS (A) // PROFIBUS (B)
Test voltage data interfaces 1.5 kV
Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 55011
Net weight 212.4 g
Housing material PA 6.6-FR
Color green
MTBF 1136 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
238 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
MTTF 1638 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
812 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
340 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
Back to top

Power supply

Nominal supply voltage 24 V DC (With UL approval)
Supply voltage range 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Typical current consumption < 90 mA (24 V DC )
Back to top

Interfaces

Interface 1 PROFIBUS acc. to IEC 61158, RS-485 2-conductor
Operating mode Through PROFIBUS connector
Connection method D-SUB-9 female connector
File format/coding UART (11 Bit, NRZ)
Data direction switching Automatic control, min. station response time 2 bits
Transmission medium 2-wire twisted pair, shielded
Transmission length ≤ 1200 m (Depends on transmission speed and cable type)
Termination resistor external
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Output nominal voltage 5 V DC ±5 %
Output current 50 mA
Back to top

Digital outputs

Output name Relay output
Output description Alarm output
Number of outputs 1
Maximum switching voltage 30 V DC (1 A)
65 V DC (0.46 A)
150 V AC (0.46 A)
Back to top

Conformance/approvals

Designation CE
Identification CE-compliant
Designation EAC
Identification EAC
Designation ATEX
Identification  II 3 G Ex nA nC IIC T4 Gc X
Additional text Please follow the special installation instructions in the documentation!
Designation UL, USA/Canada
Identification 508 Listed
Class I, Zone 2, AEx nA nC IIC T6
Class I, Zone 2, Ex nA nC IIC T6 Gc X
Class I, Div. 2, Groups A, B, C, D
Designation Corrosive gas test
Identification ISA-S71.04-1985 G3 Harsh Group A
Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Type of test Free fall in acc. with IEC 60068-2-32
Test result 1 m
Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result 5g, 10...150 Hz, 2.5 h, in XYZ direction
Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result 15g, 11 ms period, half-sine shock pulse
Noise emission EN 55011
Noise immunity EN 61000-4-2
Free from substances that could impair the application of coating according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
Contact discharge ± 6 kV
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 3 GHz
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal ± 1 kV
Standards/regulations EN 55011
EN 61000-4-6
Designation Air clearances and creepage distances
Standards/regulations DIN EN 50178, DIN EN 60950
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 19179290
eCl@ss 4.0 27250300
eCl@ss 4.1 27250300
eCl@ss 5.0 27242200
eCl@ss 5.1 27242200
eCl@ss 6.0 19179200
eCl@ss 7.0 19179290
eCl@ss 8.0 19179290
eCl@ss 9.0 19179290
Back to top

ETIM

ETIM 2.0 EC000698
ETIM 3.0 EC000698
ETIM 4.0 EC000698
ETIM 5.0 EC000310
ETIM 6.0 EC000310
ETIM 7.0 EC000310
Back to top

UNSPSC

UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 43222604
UNSPSC 18.0 43222604
UNSPSC 19.0 43222604
UNSPSC 20.0 43222604
UNSPSC 21.0 43222604
Back to top