Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
---|---|
-10 °C ... 70 °C (flexible installation) | |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Maximum altitude | ≤ 2000 m |
Degree of protection | IP00 |
≥ IP54 (Installation location) |
Max. permissible operating voltage | 25 V AC |
---|---|
60 V DC | |
Max. current carrying capacity per path | 1 A (50 °C) |
0.6 A (70°C) | |
Length of cable | 0.5 m |
External cable diameter | 6.8 mm ±0.4 mm |
Single wire, cross section | 0.14 mm² |
Single wire, cross section [AWG] | 26 |
Single wire, number of litz wires | 7 |
Single wire, material | Cu tin-plated |
Wire diameter incl. insulation | 1 mm ±0.03 mm |
Smallest bending radius, fixed installation | 58 mm |
Smallest bending radius, movable installation | 108 mm |
Bending cycles | 5000 (at a radius of ≥ 15x outside diameter) |
Cable, preassembly | Insulation displacement, IEC 60352-4/DIN EN 60352-4 |
Shielding | no |
Cable insulation resistance | ≥ 20 MΩ/km (20 °C) |
Cable resistance | ≤ 145 Ω/km (20 °C) |
Outer sheath, material | Semi-rigid PVC |
External sheath, color | gray |
Nominal operating mode | 100% operating factor |
Connection name | Field level |
---|---|
Connection in acc. with standard | IEC 60603-13 |
Connection method | IDC/FLK socket strip |
Number of connections | 1 |
Number of positions | 16 |
Insertion/withdrawal cycles | > 50 |
Pitch | 2.54 mm |
Connection name | Controller level |
---|---|
Connection method | Single wires |
Number of positions | 16 |
Note | The wires are marked and fitted with ferrules |
Flame resistance | IEC 60332-1-2 (raw cable) |
---|---|
VDE 0842, Part 332-1-2 (raw cable) | |
IEC 60332-3-22 (raw cable) | |
UL VW-1 | |
CSA FT-1 | |
Resistance to oil | can withstand occasional splashes (raw cable) |
Gasoline resistance | can withstand occasional splashes (raw cable) |
Connection in acc. with standard | CUL |
Designation | Air clearances and creepage distances |
Standards/regulations | DIN EN 50178 |
Rated insulation voltage | 63 V |
Rated surge voltage | 0.6 kV |
Insulation | Functional insulation |
Pollution degree | 2 |
Overvoltage category | II |
Connector 1 = connector 2 (optional) = wire color | IDC/FLK16 (1) = black |
---|---|
IDC/FLK16 (2) = brown | |
IDC/FLK16 (3) = red | |
IDC/FLK16 (4) = orange | |
IDC/FLK16 (5) = yellow | |
IDC/FLK16 (6) = green | |
IDC/FLK16 (7) = blue | |
IDC/FLK16 (8) = violet | |
IDC/FLK16 (9) = gray | |
IDC/FLK16 (10) = white | |
IDC/FLK16 (11) = white-black | |
IDC/FLK16 (12) = white-brown | |
IDC/FLK16 (13) = white-red | |
IDC/FLK16 (14) = white-orange | |
IDC/FLK16 (15) = white-yellow | |
IDC/FLK16 (16) = white-green |
China RoHS | Environmentally Friendly Use Period = 50 years |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 27242220 |
---|---|
eCl@ss 11.0 | 27242220 |
eCl@ss 4.0 | 27060300 |
eCl@ss 4.1 | 27060300 |
eCl@ss 5.0 | 27242200 |
eCl@ss 5.1 | 27242200 |
eCl@ss 6.0 | 27249200 |
eCl@ss 7.0 | 27249205 |
eCl@ss 8.0 | 27249205 |
eCl@ss 9.0 | 27242220 |
ETIM 2.0 | EC000237 |
---|---|
ETIM 3.0 | EC000237 |
ETIM 4.0 | EC000237 |
ETIM 5.0 | EC000237 |
ETIM 6.0 | EC000237 |
ETIM 7.0 | EC000237 |
UNSPSC 6.01 | 26121620 |
---|---|
UNSPSC 7.0901 | 26121620 |
UNSPSC 11 | 26121620 |
UNSPSC 12.01 | 26121620 |
UNSPSC 13.2 | 26121620 |
UNSPSC 18.0 | 26121620 |
UNSPSC 19.0 | 26121620 |
UNSPSC 20.0 | 26121620 |
UNSPSC 21.0 | 26121620 |
"$pageName" on