Cable - FLK 16/EZ-DR/ 800/KONFEK/S - 2318101

Assembled shielded round cable; connection 1: IDC/FLK socket strip (1x 16-position); connection 2: IDC/FLK socket strip (1x 16-position) (The braided shield is routed to a separate cable end.); cable length: 8 m

Price:

Overview

Technical data

Approvals

Downloads

Drawings



Diagram  

Diagram
Maximum permissible current per path in uncoiled state

Back to top

Ambient conditions

Ambient temperature (operation) -40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum altitude ≤ 2000 m
Degree of protection IP00
≥ IP54 (Installation location)
Back to top

General

Max. permissible operating voltage 25 V AC
60 V DC
Max. current carrying capacity per path 1 A (50 °C)
0.6 A (70°C)
Length of cable 8 m
External cable diameter 7 mm ±0.4 mm
Single wire, cross section 0.14 mm²
Single wire, cross section [AWG] 26
Single wire, number of litz wires 7
Single wire, material Cu tin-plated
Wire diameter incl. insulation 1 mm ±0.03 mm
Smallest bending radius, fixed installation 74 mm
Smallest bending radius, movable installation 133 mm
Bending cycles 5000 (at a radius of ≥ 15x outside diameter)
Cable, preassembly Insulation displacement, IEC 60352-4/DIN EN 60352-4
Shielding yes
Tinned copper-braided shield, approx. 85% covering
Cable insulation resistance ≥ 20 MΩ/km (20 °C)
Cable resistance ≤ 145 Ω/km (20 °C)
Outer sheath, material Semi-rigid PVC
External sheath, color gray
Nominal operating mode 100% operating factor
Back to top

Connection data

Connection name Field level
Connection in acc. with standard IEC 60603-13
Connection method IDC/FLK socket strip
Number of connections 1
Number of positions 16
Note The braided shield is routed to a separate cable end.
The separate cable end is approximately 0.5 m long (H05V-K 1 mm², black)
Insertion/withdrawal cycles > 50
Pitch 2.54 mm
Back to top

Connection data 2

Connection name Controller level
Connection in acc. with standard IEC 60603-13
Connection method IDC/FLK socket strip
Number of connections 1
Number of positions 16
Insertion/withdrawal cycles > 50
Pitch 2.54 mm
Back to top

Standards and Regulations

Flame resistance IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1
Resistance to oil can withstand occasional splashes (raw cable)
Gasoline resistance can withstand occasional splashes (raw cable)
Connection in acc. with standard CUL
Designation Air clearances and creepage distances
Standards/regulations DIN EN 50178
Rated insulation voltage 63 V
Rated surge voltage 0.6 kV
Insulation Functional insulation
Pollution degree 2
Overvoltage category II
Back to top

Supported controller

Controller universal
Back to top

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27242220
eCl@ss 11.0 27242220
eCl@ss 4.0 27060300
eCl@ss 4.1 27060300
eCl@ss 5.0 27242200
eCl@ss 5.1 27242200
eCl@ss 6.0 27249200
eCl@ss 7.0 27249205
eCl@ss 8.0 27249205
eCl@ss 9.0 27242220
Back to top

ETIM

ETIM 2.0 EC000237
ETIM 3.0 EC000237
ETIM 4.0 EC000237
ETIM 5.0 EC000237
ETIM 6.0 EC000237
ETIM 7.0 EC000237
Back to top

UNSPSC

UNSPSC 6.01 26121620
UNSPSC 7.0901 26121620
UNSPSC 11 26121620
UNSPSC 12.01 26121620
UNSPSC 13.2 26121620
UNSPSC 18.0 26121620
UNSPSC 19.0 26121620
UNSPSC 20.0 26121620
UNSPSC 21.0 26121620
Back to top

PHOENIX CONTACT
SEA Pte. Ltd.

105 Eunos Avenue 3
#04-00
Singapore 409836
+65 6228 4900
  • Create PDF