Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|---|
Use in potentially explosive areas is not permitted in China. |
Ambient temperature (operation) | -40 °C ... 85 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Degree of protection | IP20 |
Mounting position | Any orientation on DIN rail, NS 35, in acc. with EN 60715 |
---|---|
Net weight | 114.3 g |
Color | green |
Conformance | IEC 61158-2 |
Fieldbus Foundation | FF-830 |
Supply voltage range | 9 V DC ... 32 V DC |
---|---|
Max. current consumption | 29 mA |
Typical current consumption | 27 mA |
Interface 1 | FOUNDATION Fieldbus |
---|---|
Connection method | Pluggable screw connection with test points |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Inductance Li | 10 µH |
Input voltage Ui | 32 V DC |
---|---|
Input current Ii | 274 mA (IIC) |
ATEX | Sira 13ATEX4149X; II 3G Ex nA [ic] IIC T4 Gc |
IECEx | IECEx SIR 13.0060X; Ex nA [ic] IIC T4 Gc |
CSA, USA/Canada |
Class I, Div. 2, Groups A,B,C,D; Ex nA nL IIC T4 Gc Class I, Zone 2, AEx nA nC IIC T4 Gc |
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
---|---|
Test result | 30g, 11 ms half-sine shock pulse |
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result | 5g, 10 ... 150 Hz |
Type of test | Corrosive resistance in acc. to ANSI-ISA 71.04-1985 - Severity level G3 |
Designation | Standards/regulations |
Standards/regulations | Ring wave noise immunity in acc. with IEC 61000-4-12 |
Designation | Standards/regulations |
Standards/regulations | Dry heat in acc. with IEC 61131-2 |
Designation | Standards/regulations |
Standards/regulations | Damp heat in acc. with IEC 61131-2 |
Designation | Standards/regulations |
Standards/regulations | Shock and vibration in acc. with EN 61131-2 and EN 50178 |
IEC 61158-2 | |
Flammability rating according to UL 94 | V0 |
Conformance | IEC 61158-2 |
Fieldbus Foundation | FF-830 |
ATEX | Sira 13ATEX4149X; II 3G Ex nA [ic] IIC T4 Gc |
IECEx | IECEx SIR 13.0060X; Ex nA [ic] IIC T4 Gc |
CSA, USA/Canada |
Class I, Div. 2, Groups A,B,C,D; Ex nA nL IIC T4 Gc Class I, Zone 2, AEx nA nC IIC T4 Gc |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 27242610 |
---|---|
eCl@ss 11.0 | 27242610 |
eCl@ss 4.0 | 27250200 |
eCl@ss 4.1 | 27250200 |
eCl@ss 5.0 | 27259200 |
eCl@ss 5.1 | 27259200 |
eCl@ss 6.0 | 27242600 |
eCl@ss 7.0 | 27242610 |
eCl@ss 8.0 | 27242610 |
eCl@ss 9.0 | 27242610 |
ETIM 3.0 | EC001600 |
---|---|
ETIM 4.0 | EC000261 |
ETIM 5.0 | EC001600 |
ETIM 6.0 | EC001600 |
ETIM 7.0 | EC001600 |
UNSPSC 6.01 | 30211506 |
---|---|
UNSPSC 7.0901 | 39121008 |
UNSPSC 11 | 39121008 |
UNSPSC 12.01 | 39121008 |
UNSPSC 13.2 | 32151602 |
UNSPSC 18.0 | 32151602 |
UNSPSC 19.0 | 32151602 |
UNSPSC 20.0 | 32151602 |
UNSPSC 21.0 | 32151602 |
"$pageName" on