Network cable - VS-M12MSD-M12FSD-936-LI/0,9 - 1403368

No picture available

Assembled PROFINET cable, CAT5e, shielded, star quad, AWG 22 (7-wire), black, M12 plug to M12 socket, length 0.9 m

Price:

Overview

Technical data

Downloads

Drawings



Dimensional drawing  

Dimensional drawing
Plug, M12 x 1, straight, shielded

Cable cross section  

Cable cross section
PROFINET railway applications [936]



Back to top

Dimensions

Length of cable 0.9 m
Back to top

General data

Rated current at 40°C 4 A
Rated voltage 48 V AC
60 V DC
Number of positions 4
Overvoltage category II
Degree of pollution 3
Back to top

Standards and Regulations

Flammability rating according to UL 94 V0
Back to top

Cable

Cable type PROFINET railway applications
Cable type (abbreviation) 936
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
Cable structure 1x4xAWG22/7; SF/TQ
Conductor cross section 4x 0.34 mm²
AWG signal line 22
Conductor structure signal line 7x 0.25 mm
Core diameter including insulation 1.95 mm
Wire colors white-blue, orange-yellow
Overall twist Star quad
Shielding Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering 100 %
External sheath, color black RAL 9005
Outer sheath thickness ≥ 0.8 mm
External cable diameter D 7.25 mm ±0,3 mm
Minimum bending radius, fixed installation 6 x D
Minimum bending radius, flexible installation 10 x D
Cable weight 81 g/m
Outer sheath, material PE-X
Material conductor insulation PE-X
Conductor material silver-plated Cu litz wires
Conductor resistance ≤ 54.4 Ω/km
Working capacitance ≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Wave impedance 100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT) 80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT) 80 dB (with 1 MHz)
70 dB (at 4 МHz)
65 dB (at 10 MHz)
58 dB (at 31.5 МHz)
59 dB (at 62.5 МHz)
67 dB (at 100 MHz)
Attenuation 2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
Return loss (RL) 35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Signal speed 66 c
Shield attenuation 40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance 200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable 300 V AC
Test voltage, cable 2000 V AC (50 Hz, 5 minutes)
Fire protection in rail vehicles BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance EN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free According to EN 50267-2-1
Resistance to oil according to IRM 902, 72 h at 100 °C
Other resistance Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosiveness EN 50267-2-2
Fume toxicity BS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation) -50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 4.0 24010400
eCl@ss 4.1 24010400
eCl@ss 5.0 19030300
eCl@ss 5.1 19030300
eCl@ss 6.0 27061800
eCl@ss 7.0 27060308
eCl@ss 8.0 27060308
eCl@ss 9.0 27060308
Back to top

ETIM

ETIM 3.0 EC000830
ETIM 4.0 EC000830
ETIM 5.0 EC002599
ETIM 6.0 EC001262
ETIM 7.0 EC001262
Back to top

UNSPSC

UNSPSC 6.01 31261501
UNSPSC 7.0901 31261501
UNSPSC 11 31261501
UNSPSC 12.01 31261501
UNSPSC 13.2 26121604