Network cable - VS-M12FSBP-M12MS-936-LI/1,14 - 1403162

Network cable, PROFINET CAT5 (100 Mbps), 4-position, PE-X, black RAL 9005, shielded, Plug straight M12 SPEEDCON / IP67, coding: D, on Flush-type socket straight M12 / IP67, coding: D, cable length: 1.14 m

Price:

Overview

Technical data

Approvals

Downloads

Drawings



Dimensional drawing  

Dimensional drawing
M12 flush-type connector

Dimensional drawing  

Dimensional drawing
Housing cutout for M16 fastening thread, mounting panel with feed-through hole (alternatively with surface as protection against rotation)



Dimensional drawing  

Dimensional drawing
Plug, M12 x 1, straight, shielded

Circuit diagram  

Circuit diagram
Contact assignment of the M12 plugs



Schematic diagram  

Schematic diagram
Pin assignment M12 socket, 4-pos., D-coded, female side

Schematic diagram  

Schematic diagram
Pin assignment M12 male connector, 4-pos., D-coded, male side



Cable cross section  

Cable cross section
PROFINET railway applications [936]

Back to top

Dimensions

Length of cable 1.14 m
Back to top

Ambient conditions

Degree of protection IP65
IP67
Ambient temperature (operation) -25 °C ... 90 °C (Plug / socket)
-40 °C ... 90 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)
Back to top

General data

Rated current at 40°C 4 A
Rated voltage 250 V
Number of positions 4
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
Standards/regulations M12 connector IEC 61076-2-101
Overvoltage category II
Back to top

Characteristics head 1

Head type Plug straight M12 SPEEDCON / IP67
No. of positions (pin connector pattern) 4
Coding D (Data)
Color black
Material (component) CuSn (Contact)
Ni/Au (Contact surface)
PA (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Insulation resistance ≥ 100 MΩ
Insertion/withdrawal cycles ≥ 100
Torque 0.4 Nm
Ambient temperature (operation) -25 °C ... 90 °C
Back to top

Characteristics head 2

Head type Flush-type socket straight M12 / IP67
No. of positions (pin connector pattern) 4
Coding D (Data)
Material (component) CuZn (Contact)
Ni/Au (Contact surface)
PA 6.6 (Contact carriers)
FKM (O-ring)
Zinc die-cast, nickel-plated (Housing)
Insertion/withdrawal cycles ≥ 100
Ambient temperature (operation) -40 °C ... 85 °C
Back to top

Standards and Regulations

Standard designation M12 connector
Standards/regulations IEC 61076-2-101
Back to top

Cable

Cable type PROFINET railway applications
Cable type (abbreviation) 936
Signal type/category PROFINET CAT5 (IEC 11801), 100 Mbps
Cable structure 1x4xAWG22/7; SF/TQ
Conductor cross section 4x 0.34 mm²
AWG signal line 22
Conductor structure signal line 7x 0.25 mm
Core diameter including insulation 1.95 mm
Wire colors white-blue, orange-yellow
Overall twist Star quad
Shielding Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering 100 %
External sheath, color black RAL 9005
Outer sheath thickness ≥ 0.8 mm
External cable diameter D 7.25 mm ±0,3 mm
Minimum bending radius, fixed installation 6 x D
Minimum bending radius, flexible installation 10 x D
Cable weight 81 g/m
Outer sheath, material PE-X
Material conductor insulation PE-X
Conductor material silver-plated Cu litz wires
Conductor resistance ≤ 54.4 Ω/km
Working capacitance ≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Wave impedance 100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT) 80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT) 80 dB (with 1 MHz)
70 dB (at 4 МHz)
65 dB (at 10 MHz)
58 dB (at 31.5 МHz)
59 dB (at 62.5 МHz)
67 dB (at 100 MHz)
Attenuation 2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
Return loss (RL) 35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Signal speed 66 c
Shield attenuation 40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance 200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable 300 V AC
Test voltage, cable 2000 V AC (50 Hz, 5 minutes)
Fire protection in rail vehicles BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance EN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free According to EN 50267-2-1
Resistance to oil according to IRM 902, 72 h at 100 °C
Other resistance Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosiveness EN 50267-2-2
Fume toxicity BS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation) -50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.0 27060300
eCl@ss 4.1 27060300
eCl@ss 5.0 27061800
eCl@ss 5.1 27061800
eCl@ss 6.0 27279200
eCl@ss 7.0 27440103
eCl@ss 8.0 27440103
eCl@ss 9.0 27440102
Back to top

ETIM

ETIM 4.0 EC000830
ETIM 5.0 EC002061
ETIM 6.0 EC002061
Back to top

UNSPSC

UNSPSC 6.01 31251501
UNSPSC 7.0901 31251501
UNSPSC 11 31251501
UNSPSC 12.01 31251501
UNSPSC 13.2 39121413
Back to top

PHOENIX CONTACT
SEA Pte. Ltd.

105 Eunos Avenue 3
#04-00
Singapore 409836
+65 6228 4900
  • Create PDF
  • Recommend
  • Feedback