Number of levels | 1 |
---|---|
Number of connections | 4 |
Nominal cross section | 2.5 mm² |
Color | orange |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Rated surge voltage | 4 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Maximum power dissipation for nominal condition | 0.77 W |
Connection in acc. with standard | IEC 60947-7-1 |
Nominal current IN | 30 A (For central infeed and 4 mm² conductor cross section) |
18 A (For single-sided infeed and 2.5 mm² conductor cross section) | |
Maximum load current | 30 A (with 4 mm² conductor cross section) |
Nominal voltage UN | 250 V |
Open side panel | No |
Width | 10.4 mm |
---|---|
End cover width | 2.2 mm |
Length | 75 mm |
Height NS 35/7,5 | 44.5 mm |
Height NS 35/15 | 52 mm |
Connection method | Spring-cage connection |
---|---|
Conductor cross section solid min. | 0.08 mm² |
Conductor cross section solid max. | 4 mm² |
Conductor cross section flexible min. | 0.08 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 28 |
Conductor cross section AWG max. | 12 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum | 0.5 mm² |
Stripping length | 8 mm ... 10 mm |
Operating temperature | -60 °C ... 105 °C (max. short-term operating temperature 130°C) |
---|---|
Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Permissible humidity (storage/transport) | 30 % ... 70 % |
Ambient temperature (assembly) | -5 °C ... 70 °C |
Ambient temperature (actuation) | -5 °C ... 70 °C |
Connection in acc. with standard | CUL |
---|---|
IEC 60947-7-1 | |
Flammability rating according to UL 94 | V0 |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
eCl@ss 10.0.1 | 27141128 |
---|---|
eCl@ss 11.0 | 27141128 |
eCl@ss 4.0 | 27141100 |
eCl@ss 4.1 | 27141100 |
eCl@ss 5.0 | 27141100 |
eCl@ss 5.1 | 27141100 |
eCl@ss 6.0 | 27141100 |
eCl@ss 7.0 | 27141128 |
eCl@ss 9.0 | 27141128 |
ETIM 2.0 | EC000900 |
---|---|
ETIM 3.0 | EC000900 |
ETIM 4.0 | EC000900 |
ETIM 5.0 | EC000900 |
ETIM 6.0 | EC000900 |
ETIM 7.0 | EC000900 |
UNSPSC 6.01 | 30211811 |
---|---|
UNSPSC 7.0901 | 39121410 |
UNSPSC 11 | 39121410 |
UNSPSC 12.01 | 39121410 |
UNSPSC 13.2 | 39121410 |
UNSPSC 18.0 | 39121410 |
UNSPSC 19.0 | 39121410 |
UNSPSC 20.0 | 39121410 |
UNSPSC 21.0 | 39121410 |
"$pageName" on