Number of levels | 3 |
---|---|
Number of connections | 5 |
Nominal cross section | 2.5 mm² |
Color | gray |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Rated surge voltage | 4 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Maximum power dissipation for nominal condition | 0.77 W (the value is multiplied when connecting multiple levels) |
Connection in acc. with standard | IEC 60947-7-1 |
Nominal current IN | 18 A |
Maximum load current | 18 A (with 4 mm² conductor cross section) |
Nominal voltage UN | 250 V |
Open side panel | Yes |
Shock protection test specification | DIN EN 50274 (VDE 0660-514):2002-11 |
Back of the hand protection | guaranteed |
Finger protection | guaranteed |
Result of surge voltage test | Test passed |
Surge voltage test setpoint | 4.8 kV |
Result of power-frequency withstand voltage test | Test passed |
Power frequency withstand voltage setpoint | 1.5 kV |
Checking the mechanical stability of terminal points (5 x conductor connection) | Test passed |
Result of flexion and pull-out test | Test passed |
Bending test rotation speed | 10 rpm |
Bending test turns | 135 |
Bending test conductor cross section/weight | 0.08 mm² / 0.1 kg |
2.5 mm² / 0.7 kg | |
4 mm² / 0.9 kg | |
Tensile test result | Test passed |
Conductor cross section tensile test | 0.08 mm² |
Tractive force setpoint | 5 N |
Conductor cross section tensile test | 2.5 mm² |
Tractive force setpoint | 50 N |
Conductor cross section tensile test | 4 mm² |
Tractive force setpoint | 60 N |
Result of tight fit on support | Test passed |
Tight fit on carrier | NS 35 |
Setpoint | 1 N |
Result of voltage-drop test | Test passed |
Requirements, voltage drop | ≤ 3.2 mV |
Result of temperature-rise test | Test passed |
Short circuit stability result | Test passed |
Conductor cross section short circuit testing | 2.5 mm² |
Short-time current | 0.3 kA |
Result of aging test | Test passed |
Ageing test for screwless modular terminal block temperature cycles | 192 |
Result of thermal test | Test passed |
Proof of thermal characteristics (needle flame) effective duration | 30 s |
Relative insulation material temperature index (Elec.; UL 746 B) | 130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Static insulating material application in cold | -60 °C |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Width | 5.2 mm |
---|---|
End cover width | 2.2 mm |
Length | 92.3 mm |
Height NS 35/7,5 | 44.5 mm |
Height NS 35/15 | 52 mm |
Connection method | Spring-cage connection |
---|---|
Conductor cross section solid min. | 0.08 mm² |
Conductor cross section solid max. | 4 mm² |
Conductor cross section flexible min. | 0.08 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 28 |
Conductor cross section AWG max. | 12 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum | 0.5 mm² |
Stripping length | 8 mm ... 10 mm |
Operating temperature | -60 °C ... 105 °C (max. short-term operating temperature 130°C) |
---|---|
Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Permissible humidity (storage/transport) | 30 % ... 70 % |
Ambient temperature (assembly) | -5 °C ... 70 °C |
Ambient temperature (actuation) | -5 °C ... 70 °C |
Connection in acc. with standard | CUL |
---|---|
IEC 60947-7-1 | |
Flammability rating according to UL 94 | V0 |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
eCl@ss 10.0.1 | 27141128 |
---|---|
eCl@ss 11.0 | 27141128 |
eCl@ss 4.0 | 27141100 |
eCl@ss 4.1 | 27141100 |
eCl@ss 5.0 | 27141100 |
eCl@ss 5.1 | 27141100 |
eCl@ss 6.0 | 27141100 |
eCl@ss 7.0 | 27141128 |
eCl@ss 9.0 | 27141128 |
ETIM 2.0 | EC000900 |
---|---|
ETIM 3.0 | EC000900 |
ETIM 4.0 | EC000900 |
ETIM 5.0 | EC000900 |
ETIM 6.0 | EC000900 |
ETIM 7.0 | EC000900 |
UNSPSC 6.01 | 30211811 |
---|---|
UNSPSC 7.0901 | 39121410 |
UNSPSC 11 | 39121410 |
UNSPSC 12.01 | 39121410 |
UNSPSC 13.2 | 39121410 |
UNSPSC 18.0 | 39121410 |
UNSPSC 19.0 | 39121410 |
UNSPSC 20.0 | 39121410 |
UNSPSC 21.0 | 39121410 |
"$pageName" on