Ambient temperature (operation) | -25 °C ... 55 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Supply voltage | 24 V DC ±15 % (PELV, controlled, residual ripple < 5% ) |
---|---|
Current consumption | max. 40 mA |
Protection | min. 0.25 A (to be performed externally) |
max. 8 A (to be performed externally) |
Designation | FO1A, FO1B |
---|---|
Output description | Semiconductor outputs, p-wired |
Number of outputs | 2 |
Output voltage | min. (UB - 1.5 V (HIGH FO1A, FO1B)) |
max. (UB (HIGH FO1A, FO1B)) | |
min. 0 V DC (LOW FO1A/FO1B) | |
max. 1 V DC (LOW FO1A/FO1B) | |
Switching current | min. 1 mA (per safety output) |
max. 150 mA (per safety output) | |
Short-circuit-proof | yes |
Utilization category in accordance with IEC 60947-5-2 | 150 mA (24 V (DC13)) |
Note on protection circuit | NOTE: Protect the outputs under inductive loads with a freewheeling diode. |
Residual current | ≤ 0.25 mA |
Designation | DGN |
---|---|
Output description | p-wired |
Number of outputs | 1 |
Short-circuit-proof | yes |
Output voltage | min. (UB - 1.5 V (HIGH)) |
max. (UB (HIGH)) | |
min. 0 V DC (LOW) | |
max. 1 V DC (LOW) | |
Current IDGN | min. 1 mA |
max. 50 mA |
Switch-on delay | typ. 5 s (after switching UB on) |
---|---|
Risk time according to EN 60947-5-3 | max. 125 ms (Stand-alone device) |
Delay time | typ. 10 ms (Risk time delay per device) |
Switch-on time | max. 400 ms (for the safety outputs) |
Discrepancy time | max. 10 ms (between the safety outputs) |
Test pulses | typ. 300 µs (Test pulse duration) |
approx. 100 ms (Test pulse interval) |
Net weight | 40.8 g |
---|---|
Mounting position | any |
Mounting type | not flush |
Minimum distance | 140 mm (between two safety circuits) |
7 mm (between sensor and actuator when traveling in the Y-direction) | |
Assembly instructions | Note EN ISO 14119 |
Maximum tightening torque to secure: 0.8 Nm | |
Degree of protection | IP65/IP67/IP69/IP69K |
IP67 (with SAC cabling) | |
Protection class | III |
Short-circuit current | typ. 100 A (conditional short-circuit current) |
Switching frequency | max. 1 Hz |
Housing material | PBT |
Housing color | yellow |
Status display | 2 LEDs |
Connection method | Connector |
---|---|
Connection technology | M12 connector |
pluggable | no |
Number of positions | 8 |
Designation | IEC 61508 - High demand |
---|---|
Safety Integrity Level (SIL) | 3 |
Designation | EN ISO 13849 |
Performance level (PL) | e |
Category | 4 |
Rated insulation voltage | max. 300 V |
---|---|
Rated surge voltage | max. 1.5 kV |
Degree of pollution | 3 |
Vibration (operation) | in accordance with EN 60947-5-2 |
EMC conformance | EN 60947-5-3 |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 27272403 |
---|---|
eCl@ss 11.0 | 27272403 |
eCl@ss 5.0 | 27272400 |
eCl@ss 6.0 | 27272400 |
eCl@ss 7.0 | 27272403 |
eCl@ss 9.0 | 27272403 |
"$pageName" on