Dimensional drawing |
![]() |
---|---|
Width | 35 mm |
Height | 126.1 mm |
Depth | 54 mm |
Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Ambient temperature (operation) | -25 °C ... 60 °C (up to 2000 m above sea level) |
---|---|
-25 °C ... 55 °C (2000 m above sea level ... 3000 m above sea level) | |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level (at an operating temperature of up to 55°C, maximum)) |
Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
Degree of protection | IP20 |
Designation | Axioline F connector |
---|---|
Connection method | Push-in connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Mounting type | DIN rail |
---|---|
Color | traffic grey A RAL 7042 |
Net weight | 157.8 g |
Diagnostics messages | Bus error in INTERBUS Yes |
Peripheral fault in INTERBUS Yes | |
Mounting type | DIN rail mounting |
Interface | INTERBUS remote bus |
---|---|
Number | 1 |
Connection method | D-SUB-9 female connector |
Designation | Supply of the logic voltage UL |
---|---|
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current consumption | typ. 110 mA (without IBS OPTOSUB ... FO adapter) |
max. 185 mA (with IBS OPTOSUB ... FO adapter) | |
Protective circuit | Polarity reversal protection of the supply voltage Polarity protection diode |
Transient protection Suppressor diode |
Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
---|---|
Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV |
Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV |
Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |
Interference emission | Noise emission test according to EN 61000-6-3 Class B |
Mechanical tests | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse |
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
"$pageName" on