Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -25 °C ... 55 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 10 kPa ... 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP20 |
Designation | Inline connector |
---|---|
Connection method | Spring-cage connection |
Conductor cross section solid min. | 0.08 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.08 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 28 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Mounting type | DIN rail mounting |
---|---|
Net weight | 66 g |
Diagnostics messages | Bus error in INTERBUS Yes |
Peripheral fault in INTERBUS Yes | |
Mounting type | DIN rail mounting |
Interface | INTERBUS local bus (master) |
---|---|
Number | 1 |
Connection method | Inline data jumper |
Designation | 24 V supply UILC |
---|---|
Supply voltage | 24 V DC -15 % / +20 % (acc. to EN 61131-2) |
Current consumption | 20 mA |
Designation | 7.5 V communications power UL (potential jumper) |
Supply voltage | 7.5 V DC ±5 % |
Power supply unit | max. 0.8 A DC (observe derating) |
Designation | 24 V analog supply UANA (potential jumper) |
Supply voltage | 24 V DC -15 % / +20 % |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Power supply unit | 0.5 A DC (observe derating) |
Designation | 24 V main supply UM |
Supply voltage | 24 V DC -15 % / +20 % (acc. to EN 61131-2) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Power supply unit | max. 8 A DC (sum of UM + US) |
Designation | 24 V segment supply US |
Supply voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Power supply unit | max. 8 A (sum of UM + US) |
Type of protection | Polarity reversal protection of the supply voltage |
Transient protection |
Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 EN 61000-4-2 (ESD) Criterion B, 4 kV contact discharge, 8 kV air discharge |
---|---|
Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 EN 61000-4-3 (electromagnetic fields) Criterion A, Field intensity: 10 V/m |
Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 EN 61000-4-4 Criterion B, 2 kV |
Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 EN 61000-4-5 (surge) Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical) |
Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 EN 61000-4-6 (line noise immunity) Criterion A, Test voltage 10 V |
Interference emission | Noise emission test as per EN 61000-6-4 |
Mechanical tests | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse |
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
No hazardous substances above threshold values |
eCl@ss 10.0.1 | 27242608 |
---|---|
eCl@ss 11.0 | 27242608 |
eCl@ss 6.0 | 27242600 |
eCl@ss 7.0 | 27242608 |
eCl@ss 9.0 | 27242608 |