Listă de produse amplificatoare separatoare

Filtru

12 rezultate

facetDefinition[facetId=PIM_FAC_APPROVAL_CBX_STR, helpText=, helpImageUrl=]

Approval

facetDefinition[facetId=PIM_FAC_CONNECTION_METHOD_STR, helpText=, helpImageUrl=] facetDefinition[facetId=PIM_FAC_CHANNEL_NUMBER_NUM, helpText=, helpImageUrl=]

Isolation amplifier - MACX MCR-SL-NAM-2RO - 2865010

NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using 2 separate relay outputs (N/O contacts). Line fault detection (LFD), galvanic 3-way isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-NAM-2T - 2865023

NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection (LFD), 3-way electrical isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-2NAM-T - 2865036

NAMUR isolation amplifier, 2-channel for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection (LFD), 3-way electrical isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-2NAM-RO - 2865049

NAMUR isolation amplifier,2-channel for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection (LFD), galvanic 3-way isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-2NAM-R-UP - 2865052

2-channel NAMUR isolation amplifier with wide-range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, screw connection, SIL 2

Isolation amplifier - MACX MCR-SL-NAM-R - 2865997

NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using relay output (PDT). Line fault detection (LFD), galvanic 3-way isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-NAM-R-SP - 2924252

NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using relay output (PDT). Line fault detection (LFD), galvanic 3-way isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-NAM-2RO-SP - 2924265

NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using 2 separate relay outputs (N/O contacts). Line fault detection (LFD), galvanic 3-way isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-NAM-2T-SP - 2924278

NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection (LFD), 3-way electrical isolation, SIL 2.

Isolation amplifier - MACX MCR-SL-2NAM-T-SP - 2924281

NAMUR isolation amplifier, 2-channel for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection (LFD), 3-way electrical isolation, SIL 2.

12 rezultatele

PHOENIX CONTACT SRL

Floreasca Business Park
Calea Floreasca 169 A,
Corp A, Etaj 8,
București, România,
RO-014459
0040 21 350 88 12
0040 21 350 88 13

Acest website folosește cookie-uri. Prin continuarea vizualizării site-ului nostru acceptați politicile noastre referitoare la cookie-uri. Pentru mai multe informații citiți politica noastră de confidențialitate.

Închidere