Socket Outlet - EV-T2M3SE12-3AC32A-0,7M6,0E14 - 1627693

Infrastructure Socket Outlet for charging electric vehicles with alternating current (AC), compatible with Infrastructure Plugs, Type 2, IEC 62196-2, 32 A / 480 V (AC), 12 V Locking actuator, Single wires, length: 0.7 m, Rear panel mounting, Front protective cover screw connection, Optimized insertion and withdrawal forces

Preț:

Prezentare generală

Date tehnice

Accesorii

Aprobări

Descărcări

Desene



Connection diagram  

Connection diagram
Pin assignment of Infrastructure Socket Outlet

Block diagram  

Block diagram
Block diagram of the locking actuator



Diagram  

Diagram
Locking states of the locking actuator

Dimensional drawing  

Dimensional drawing
Hole image



Dimensional drawing  

Dimensional drawing
Dimensional drawing

Schematic diagram  

Schematic diagram
Rear mounting with front protective cover screw connection
The screw connection for a protective cover (EV-T2SC-EM) from the accessories range only supports front mounting with a corresponding fixing frame (EV-T2SF-EM). The panel thickness must not exceed 5 mm. The sealing frame that is slid on from the rear must contact the housing panel flush with the flat side and must completely surround the infrastructure socket outlet.



Schematic diagram  

Schematic diagram
Operating instructions

Schematic diagram  

Schematic diagram
Detection of the Infrastructure Plug



Schematic diagram  

Schematic diagram
Installation positions

Schematic diagram  

Schematic diagram
Panel thickness for rear mounting (max. 50 mm, with Phoenix Contact protective cover, max. 22 mm)



Înapoi în sus

Product definition

Product type Infrastructure Socket Outlet for charging electric vehicles with alternating current (AC), compatible with Infrastructure Plugs
Type Front protective cover screw connection
Standards/regulations IEC 62196-2
Charging standard Type 2
Charging mode Mode 3, Case B
Note Optimized insertion and withdrawal forces
Note on the connection method Crimp connection, cannot be disconnected
Înapoi în sus

Dimensions

Height 96 mm
Width 75 mm
Depth 76.2 mm
Bore dimensions 60 mm x 60 mm
Conductor length 0.7 m (AC cables)
0.5 m (Locking actuator cables)
Cable structure 5x 6.0 mm² + 2x 0.5 mm²
Type of conductor Single wires
Înapoi în sus

Ambient conditions

Ambient temperature (operation) -30 °C ... 50 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Max. altitude 5000 m (above sea level)
Degree of protection IP44 (plugged in)
IP54 (with protective cover, see accessories)
Înapoi în sus

Electrical properties

Maximum charging power 22 kW
Type of charging current AC 3-phase
Number of phases 3
Number of power contacts 5 (L1, L2, L3, N, PE)
Rated current of power contacts 32 A
Rated voltage for power contacts 480 V AC
Number of signal contacts 2 (CP, PP)
Rated current for signal contacts 2 A
Rated voltage for signal contacts 30 V AC
Type of signal transmission Pulse width modulation
Note on the connection method Crimp connection, cannot be disconnected
Înapoi în sus

Mechanical properties

Insertion/withdrawal cycles > 10000
Insertion force < 100 N (Optimized)
Withdrawal force < 100 N (Optimized)
Înapoi în sus

Mounting

Possible mounting positions Rear panel mounting
Restrictions to mounting position Only 0 to 90 degree frontal inclination possible, see figure
Mounting position of the locking actuator Top center
Screw connection of a protective cover only possible on the front
Max. wall thickness max. 50 mm (Rear panel mounting, normative maximum specification for infrastructure plug)
max. 22 mm (Rear panel mounting, normative maximum specification for infrastructure plug when using the protective cover (Order No. 1627635) with fastening frame (Order No. 1627637))
Mounting hole diameter 7.00 mm (ø)
Înapoi în sus

Design

Design line Easy Mount
Housing color black
Customer variations On request
Înapoi în sus

Material

Material Plastic
Material surface of contacts Ag
Înapoi în sus

Locking

Locking type Locking in the inserted state with a locking mechanism
Locking voltage 12 V
Locking detection available
Mechanical emergency release available
Înapoi în sus

Locking actuator

Typical power supply at the motor 12 V
Possible power supply range at the motor 9 V ... 16 V
Typical motor current for locking 0.2 A
Max. reverse current of the motor 1 A
Max. dwell time with reverse current 1000 ms
Recommended adaptation time 600 ms
Pause time after entry or exit path 3 s
Maximum voltage for locking detection 30 V
Service life > 10000 load cycles
Ambient temperature (operation) -30 °C ... 50 °C
Length of cable 0.5 m
Înapoi în sus

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 10;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Înapoi în sus

Clasificări

eCl@ss

eCl@ss 4.0 27140800
eCl@ss 4.1 27140800
eCl@ss 5.0 27143400
eCl@ss 5.1 27143400
eCl@ss 6.0 27143400
eCl@ss 7.0 27449001
eCl@ss 8.0 27449001
eCl@ss 9.0 27144706
Înapoi în sus

ETIM

ETIM 3.0 EC002061
ETIM 4.0 EC002061
ETIM 5.0 EC001321
ETIM 6.0 EC002898
ETIM 7.0 EC002898
Înapoi în sus

UNSPSC

UNSPSC 6.01 30211923
UNSPSC 7.0901 39121522
UNSPSC 11 39121522
UNSPSC 12.01 39121522
UNSPSC 13.2 39121522
Înapoi în sus

PHOENIX CONTACT ROMANIA

Splaiul Unirii 165
Timpuri Noi Square
TNO1, Etaj 1
Bucuresti 030133
+40 21 350 88 12 - 3
+40 37 448 56 32 - 7
  • Creare PDF
  • Recomandare
  • Feedback

Acest website folosește cookie-uri. Prin continuarea vizualizării site-ului nostru acceptați politicile noastre referitoare la cookie-uri. Pentru mai multe informații citiți politica noastră de confidențialitate.

Închidere