Surge protection plug - PT 3-PB-ST - 2858030

Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode voltage coarse protection to ground.

Preço:

Visão geral

Dados técnicos

Acessórios

Certificações

Downloads

Desenhos



Application drawing  

Application drawing
Connecting M-UFB IBS-MUX to the field multiplexer

Dimensional drawing  

Dimensional drawing
The figure shows the complete module consisting of a base element and connector



Circuit diagram  

Circuit diagram

Voltar para cima

Dimensions

Height 45 mm
Width 17.7 mm
Depth 52 mm
Horizontal pitch 1 Div.
Complete module height 90 mm
Complete module width 17.7 mm
Complete module depth 65.5 mm
Voltar para cima

Ambient conditions

Ambient temperature (operation) -40 °C ... 85 °C
Altitude max. 2000 m
Degree of protection IP20
Voltar para cima

General

Housing material PA
Flammability rating according to UL 94 V-0
Color black
Standards for cearances and creepage distances DIN EN 61664-1
IEC 60664-1
Mounting type on base element
Type Male
Number of positions 2
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.10
Voltar para cima

Protective circuit

IEC test classification C1
C2
C3
D1
VDE requirement class C1
C2
C3
D1
Nominal voltage UN 5 V DC
Maximum continuous voltage UC 5.2 V DC
3.6 V AC
Rated current 450 mA (45 °C)
Operating effective current IC at UC ≤ 300 µA
Residual current IPE ≤ 300 µA (with PT 1X2-BE)
≤ 1 µA (with PT 1X2+F-BE)
Nominal discharge current In (8/20) µs (line-line) 10 kA
Nominal discharge current In (8/20) µs (line-earth) 10 kA
Pulse discharge current Iimp (10/350) µs 2.5 kA
Total discharge current Itotal (8/20) µs 20 kA
Max. discharge current Imax (8/20) µs maximum (line-line) 10 kA
Max. discharge current Imax (8/20) µs maximum (line-earth) 10 kA
Nominal pulse current Ian (10/1000) µs (line-line) 90 A
Output voltage limitation at 1 kV/µs (line-line) spike ≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 55 V (with PT 1X2-BE)
≤ 700 V (with PT 1X2+F-BE)
Output voltage limitation at 1 kV/µs (line-line) static ≤ 15 V
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 15 V
≤ 30 V (with PT 1X2+F-BE)
Residual voltage at In (line-line) ≤ 15 V
Residual voltage at In (line-earth) ≤ 30 V (with PT 1X2-BE)
Residual voltage at In (line-signalground) ≤ 15 V (with PT 1X2-BE)
Residual voltage with Ian (10/1000) µs (line-line) ≤ 15 V
Residual voltage with Ian (10/1000) µs (line-signalground) ≤ 15 V
Voltage protection level Up (line-line) ≤ 70 V (C1 - 1 kV/500 A)
≤ 45 V (C3 - 25 A)
≤ 100 V (C2 - 10 kV / 5 kA)
≤ 70 V (6 kV / 3 kA)
Voltage protection level Up (line-earth) ≤ 80 V (C1 - 1 kV/500 A)
≤ 110 V (C2 - 10 kV / 5 kA)
≤ 100 V (6 kV / 3 kA)
≤ 45 V (C3 - 25 A)
Voltage protection level Up (line-signalground) ≤ 45 V (C3 - 25 A)
Response time tA (line-line) ≤ 500 ns
Response time tA (line-signalground) ≤ 500 ns
Response time tA (line-earth) ≤ 500 ns
Input attenuation aE, sym. typ. 0.3 dB (≤ 5 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm system typ. 60 MHz
Capacity (line-line) typ. 30 pF
Resistance in series 2.2 Ω ±10 % (7-8/11-12)
Max. required back-up fuse 500 mA (T)
Impulse durability (line-line) C2 - 10 kV / 5 kA
C3 - 90 A
Impulse durability (line-earth) C2 - 10 kV / 5 kA
C3 - 90 A
D1 - 2.5 kA
Voltar para cima

Connection data

Connection method Screw connection (in connection with the base element)
Screw thread M3
Tightening torque 0.8 Nm
Stripping length 8 mm
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section solid 0.2 mm² ... 4 mm²
Conductor cross section AWG 24 ... 12
Voltar para cima

Connection, equipotential bonding

Stripping length 8 mm
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Voltar para cima

Standards and Regulations

Standards/specifications EN 61643-21/A1 2009
IEC 61643-21/A1 2008
Voltar para cima

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Voltar para cima

Classificações

eCl@ss

eCl@ss 4.0 27140201
eCl@ss 4.1 27130801
eCl@ss 5.0 27130801
eCl@ss 5.1 27130800
eCl@ss 6.0 27130800
eCl@ss 7.0 27130807
eCl@ss 8.0 27130807
eCl@ss 9.0 27130807
Voltar para cima

ETIM

ETIM 2.0 EC000943
ETIM 3.0 EC000943
ETIM 4.0 EC000943
ETIM 5.0 EC000943
ETIM 6.0 EC000943
ETIM 7.0 EC000943
Voltar para cima

UNSPSC

UNSPSC 6.01 30212010
UNSPSC 7.0901 39121610
UNSPSC 11 39121610
UNSPSC 12.01 39121610
UNSPSC 13.2 39121620
Voltar para cima

Phoenix Contact S.A.

Sintra Business Park,
Edifício n°1
Zona Industrial da Abrunheira
2710-089 SINTRA

Horário: 9h -13h e 14h -18h
(+351) 21 911 2760
  • Criar PDF
  • Recomendar
  • Feedback

Este website usa cookies. Ao continuar a navegar, está a concordar com a nossa política de cookies. Saiba mais sobre a nossa política de privacidade.

Fechar