Injector - INJ 2102-T - 2703012

PoE injector, 30 W, RJ45 socket on IDC terminal blocks, 10/100/1000 Mbps, DIN rail mounting, IP20, potential separation, shield contacting with strain relief, shield current monitoring, surge protection

Preço:

Visão geral

Dados técnicos

Acessórios

Certificações

Downloads

Desenhos



Dimensional drawing  

Dimensional drawing

Circuit diagram  

Circuit diagram
Circuit diagram (surge protection only)



Schematic diagram  

Schematic diagram
Mounting

Schematic diagram  

Schematic diagram
Removal



Schematic diagram  

Schematic diagram
Front view

Schematic diagram  

Schematic diagram
Open shield contact spring



Schematic diagram  

Schematic diagram
Inserting the cable

Schematic diagram  

Schematic diagram
Close shield contact spring



Schematic diagram  

Schematic diagram
Stripping length

Voltar para cima

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Voltar para cima

Dimensions

Dimensional drawing
Width 30.2 mm
Height 130 mm
Depth 120 mm
Voltar para cima

Ambient conditions

Ambient temperature (operation) -40 °C ... 75 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Altitude 5000 m (For restrictions see manufacturer's declaration)
Degree of protection IP20 (Manufacturer's declaration)
Voltar para cima

General

Electrical isolation VCC // SCM + FE // PoE
Test voltage data interface/power supply 1.5 kV AC (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Mounting position vertical
Net weight 324.72 g
Housing material Plastic
Color gray
MTTF 1510 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
661 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
256 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
Conformance CE-compliant
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Division 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Voltar para cima

Power supply

Nominal supply voltage 24 V DC
48 V DC
Supply voltage range 18 V DC ... 57 V DC
Max. current consumption 2.1 A
1.4 A (24 V DC)
0.7 A (48 V DC)
Power consumption ≤ 75 W
Protective circuit Reverse polarity protection
Conductor cross section flexible max. 4.00 mm²
Conductor cross section flexible min. 0.75 mm²
Conductor cross section solid max. 4.00 mm²
Conductor cross section solid min. 0.75 mm²
Conductor cross section AWG max. 12
Conductor cross section AWG min. 20
Voltar para cima

Serial interface

Interface 1 Ethernet
Connection method IDC connection
Transmission length 100 m (including patch cables)
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 0.34 mm²
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 0.34 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 22
Wire diameter incl. insulation 1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request)
Pin assignment 1:1
Basic functions PSE/Midspan, compliant with IEEE 802.3af, at
Serial transmission speed 10/100/1000 Mbps
Output nominal voltage 54 V DC (PoE)
Output power 30 W
Maximum output power 40 W
Interface 2 Ethernet
Connection method RJ45 CAT5e
Voltar para cima

Function

Designation Shield current monitoring
Switch-on threshold ≥ 30 mA
Local diagnostics Yellow LED
Precision ± 5 %
Response time 3 s
Continuous shield current ≤ 2 A
Power consumption 270 mW (Shield current monitoring)
Voltar para cima

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result 10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g
Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result 30g for 11 ms, three shocks in each spatial direction
Type of test Continuous shock according to EN 60068-2-27/IEC 60068-2-27
Test result 10g for 16 ms, 1000 shocks in each spatial direction
Standards/regulations EN 61000-4-2
Contact discharge ± 6 kV (Test Level 3)
Indirect discharge ± 6 kV
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 3 GHz (Test Level 3)
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal ± 1 kV (Data line, asymmetrical)
± 2 kV (I/O cable on field side only, asymmetric)
Standards/regulations EN 61000-6-4
EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Standards/regulations IEC 61643-21
IEC test classification C2
Conformance CE-compliant
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Division 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Noxious gas test ISA-S71.04-1985 G3 Harsh Group A
Voltar para cima

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Voltar para cima

Classificações

eCl@ss

eCl@ss 6.0 19170100
eCl@ss 7.0 19170112
eCl@ss 8.0 19170112
eCl@ss 9.0 19170112
Voltar para cima

ETIM

ETIM 5.0 EC002599
ETIM 6.0 EC002599
ETIM 7.0 EC002599
Voltar para cima

Phoenix Contact S.A.

Sintra Business Park,
Edifício n°1
Zona Industrial da Abrunheira
2710-089 SINTRA

Horário: 9h -13h e 14h -18h
(+351) 21 911 2760
  • Criar PDF
  • Recomendar
  • Feedback

Este website usa cookies. Ao continuar a navegar, está a concordar com a nossa política de cookies. Saiba mais sobre a nossa política de privacidade.

Fechar