DC charging controller - EV-PLCC-AC1-DC1 - 1624130

Programmable charging controller for DC and AC charging of electric vehicles in accordance with IEC 61851-1,-23, DIN SPEC 70121 with integrated 3G mobile network modem

Price:

Overview

Technical data

Accessories

Downloads

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Back to top

Product definition

Product type Programmable charging controller for DC and AC charging of electric vehicles in accordance with IEC 61851-1,-23, DIN SPEC 70121 with integrated 3G mobile network modem
Type in housing
Number of charging points 2
Back to top

Dimensions

Height 158.00 mm
Width 285.00 mm
Depth 70.00 mm
Back to top

Ambient conditions

Ambient temperature (operation) -25 °C ... 55 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
Permissible humidity (storage/transport) 10 % ... 95 % (according to EN 61131-2)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Degree of protection IP20
Vibration (operation) 5g
Vibration (storage/transport) 5g
Shock (operation) 25g (Criterion 1, according to IEC 60068-2-27)
Back to top

DC charging interface

Standards/regulations IEC 61851-1
IEC 61851-23
Charging mode Mode 4
Communication DIN SPEC 70121
Cable length max. 10 m
Proximity Analog input, reserved for future applications
Temperature sensors 2x Pt 1000
Temperature range -20 °C ... 120 °C
Relay output DC charging enabled
Maximum switching voltage 30 V (External supply)
Max. switching current 6 A (External supply)
Back to top

AC charging interface

Standards/regulations IEC 61851-1, Annex A+B
Charging mode Mode 3, Case B + C
Locking control Relay output, supplied internally
Voltage ± 12 V
Maximum current for locking actuators 2 A
Activation time Can be set via application program
Behavior in the event of voltage drop Automatic unlocking
Locking feedback Resistance measurement
Switching thresholds Can be set via application program
Temperature sensors 1x Pt 1000 (evaluation via application program)
Temperature range -20 °C ... 120 °C
Relay output AC charging enabled
Maximum switching voltage 30 V (External supply)
Max. switching current 6 A (External supply)
Back to top

IEC 61131 runtime system

Number of control tasks 8
Processing speed 1.3 ms (1 K mix instructions)
90 µs (1 K bit instructions)
Program memory 1 Mbyte (86 K instructions (IL))
Battery Integrated (rechargeable battery buffered)
Retentive mass storage 48 kByte (NVRAM)
Mass storage 1 Mbyte
Parameterization memory min. 4 Mbyte (depending on storage media)
Diagnostics tool DIAG+
Programming tool PC WORX
Runtime system eCLR
Realtime clock Yes
Back to top

Digital inputs

Number inputs 16
Connection method COMBICON connectors
Description of the input EN 61131-2 type 1
Input voltage range -0.5 V DC ... 30 V DC
-0.5 V DC ... 5 V DC (“0” signal)
15 V DC ... 30 V DC (“1” signal)
Typical response time min. 3 ms
Cable length max. 30 m
Back to top

Digital outputs

Number outputs 16
Connection method COMBICON connectors
Output voltage 24 V DC
Maximum output current per channel 500 mA
Resistance to permanent reverse voltage max. 500 mA
Back to top

Ethernet data interfaces

Number of interfaces 2
Connection method RJ45 socket
Transmission speed 100 Mbps
Transmission length max. 100 m
Back to top

RS-485 data interfaces

Number of interfaces 2
Connection method COMBICON connectors
Transmission length max. 3 m (with shielded cable max. 30 m)
Termination resistor 120 Ω (Can be connected internally)
Back to top

RS-232 data interfaces

Number of interfaces 2
Connection method COMBICON connectors
Transmission length max. 3 m (with shielded cable max. 30 m)
Back to top

CAN bus data interfaces

Number of interfaces 1 (Transparent mode, CAN 2.0a, 11 Bit Object Identifier, CAN 2.0b, 29 Bit Object Identifier)
Connection method COMBICON connectors
Transmission speed 500 kbps (Default)
125 kbps, 250 kbps, 1000 kbps (adjustable)
Transmission length max. 3 m (with shielded cable max. 30 m)
Termination resistor 120 Ω (Can be connected internally)
Back to top

Wireless interfaces

Frequency 850 MHz (0.25 W (UMTS))
1900 MHz (0.25 W (UMTS))
2100 MHz (0.25 W (UMTS))
Antenna Max. cable length of 30 m
Impedance 50 Ω
Antenna connection SMA (female)
SIM card 1.8 volt and 3 volt SIM card
GPRS Class 12, Class B
EDGE Multislot Class 10
UMTS HSPA 3GPP R6
Back to top

Connection data

Connection method COMBICON connectors
Conductor cross section flexible 0.08 mm² ... 1.5 mm²
Conductor cross section solid 0.08 mm² ... 1.5 mm²
Conductor cross section AWG 28 ... 16
Back to top

Device supply

Supply voltage 24 V DC (Length of cable max. 30 m)
Supply voltage range 19.2 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple)
Residual ripple 5 %
Supply voltage UM of the digital inputs 24 V DC -15 % / +20 % (according to EN 61131-2)
Power supply at UM max. 8 A DC (sum of UM + US)
Current consumption from UM max. 8 A DC
Supply voltage US of the digital outputs 24 V DC -15 % / +20 % (according to EN 61131-2)
Power supply at US max. 8 A DC (sum of UM + US)
Current consumption from US max. 8 A DC
Supply voltage UL 24 V DC
Power supply at UL max. 0.8 A DC
Back to top

EMC data

Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 4 kV contact discharge, 8 kV air discharge
Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, Supply lines: 1 kV, Signal/data lines: 0,5 kV
Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Interference emission Noise emission test as per EN 61000-6-4 EN 55011 Class A
Back to top

Mounting

Mounting position horizontal
Assembly instructions DIN rail mounting
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.0 27210902
eCl@ss 4.1 27371105
eCl@ss 5.0 27371801
eCl@ss 5.1 27371810
eCl@ss 6.0 27371810
eCl@ss 7.0 27371810
eCl@ss 8.0 27242207
eCl@ss 9.0 27144703
Back to top

ETIM

ETIM 3.0 EC001505
ETIM 4.0 EC001599
ETIM 5.0 EC001413
ETIM 6.0 EC002889
ETIM 7.0 EC002889
Back to top

UNSPSC

UNSPSC 6.01 30211916
UNSPSC 7.0901 39121535
UNSPSC 11 39121535
UNSPSC 12.01 39121535
UNSPSC 13.2 39121801
Back to top

PHOENIX CONTACT
GmbH & Co. KG

Flachsmarktstraße 8
D-32825 Blomberg
+49 (0) 5235-3 00
  • Create PDF
  • Feedback

This website uses cookies. Read our privacy policy for more information.

Close